Speckle-Based X-Ray Dark-Field Tomography of an Attenuating Object

被引:3
|
作者
Alloo, S. J. [1 ]
Paganin, D. M. [2 ]
Morgan, K. S. [2 ]
Kitchen, M. J. [2 ]
Stevenson, A. W. [3 ]
Mayo, S. C. [4 ]
Li, H. T. [5 ]
Kennedy, B. M. [6 ]
Maksimenko, A. [3 ]
Bowden, J. [4 ]
Pavlov, K. M. [1 ,2 ,7 ]
机构
[1] Univ Canterbury, Sch Phys & Chem Sci, Christchurch 8041, New Zealand
[2] Monash Univ, Sch Phys & Astron, Clayton, Vic 3800, Australia
[3] Australian Synchrotron, ANSTO, Clayton, Vic 3168, Australia
[4] Commonwealth Sci & Ind Res Org, Clayton, Vic 3168, Australia
[5] Univ Canterbury, Sch Math, Christchurch 8041, New Zealand
[6] Univ Canterbury, Sch Earth & Environm, Christchurch 8041, New Zealand
[7] Univ New England, Armidale, NSW 2351, Australia
来源
基金
澳大利亚研究理事会;
关键词
Speckle-Based X-Ray Imaging; Phase-Contrast Imaging; Dark-Field Imaging; Computed Tomography; PHASE-CONTRAST; COMPUTED-TOMOGRAPHY; IMAGE; RETRIEVAL;
D O I
10.1117/12.2597722
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Spatial resolution in standard phase-contrast X-ray imaging is limited by the finite number and size of detector pixels. This limits the size of features that can be seen directly in projection images or tomographic reconstructions. Dark-field imaging allows information regarding such features to be obtained, as the reconstructed image is a measure of the position-dependent small-angle X-ray scattering of incident rays from the unresolved microstructure. In this paper we utilize an intrinsic speckle-tracking-based X-ray imaging technique to obtain the effective dark-field signal from a wood sample. This effective dark-field signal is extracted using a Fokker-Planck type formalism, which models the deformations of illuminating reference-beam speckles due to both coherent and diffusive scatter from the sample. We here assume that (a) small-angle scattering fans at the exit surface of the sample are rotationally symmetric, and (b) the object has both attenuating and refractive properties. The associated inverse problem, of extracting the effective dark-field signal, is numerically stabilised using a \weighted determinants" approach. Effective dark-field projection images are presented, as well as the dark-field tomographic reconstructions obtained using Fokker-Planck implicit speckle-tracking.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Brain Connectivity Exposed by Anisotropic X-ray Dark-field Tomography
    Wieczorek, Matthias
    Schaff, Florian
    Jud, Christoph
    Pfeiffer, Daniela
    Pfeiffer, Franz
    Lasser, Tobias
    SCIENTIFIC REPORTS, 2018, 8
  • [22] X-ray Dark-Field Tomography Using Edge-Illumination
    Doherty, Adam
    Savidis, Savvis
    Astolfo, Alberto
    Massimi, Lorenzo
    Djurabekova, Nargiza
    Navarrete-Leon, Carlos
    Gerli, Mattia F. M.
    Iacoviello, Francesco
    Shearing, Paul R.
    Norman, Danielle G.
    Williams, Mark A.
    Olivo, Alessandro
    Endrizzi, Marco
    DEVELOPMENTS IN X-RAY TOMOGRAPHY XIV, 2022, 12242
  • [23] Grating-based X-ray Dark-field Computed Tomography of Living Mice
    Velroyen, A.
    Yaroshenko, A.
    Hahn, D.
    Fehringer, A.
    Tapfer, A.
    Mueller, M.
    Noel, P. B.
    Pauwels, B.
    Sasov, A.
    Yildirim, A. Oe.
    Eickelberg, O.
    Hellbach, K.
    Auweter, S. D.
    Meinel, F. G.
    Reiser, M. F.
    Bech, M.
    Pfeiffer, F.
    EBIOMEDICINE, 2015, 2 (10): : 1500 - 1506
  • [24] X-ray dark-field computed tomography for monitoring of tissue freezing
    John, Dominik
    Gottwald, Wolfgang
    Berthe, Daniel
    Wirtensohn, Sami
    Hickler, Julia
    Heck, Lisa
    Herzen, Julia
    SCIENTIFIC REPORTS, 2024, 14 (01)
  • [25] X-ray dark-field computed tomography for monitoring of tissue freezing
    Dominik John
    Wolfgang Gottwald
    Daniel Berthe
    Sami Wirtensohn
    Julia Hickler
    Lisa Heck
    Julia Herzen
    Scientific Reports, 14
  • [26] Reconstruction of scalar and vectorial components in X-ray dark-field tomography
    Bayer, Florian L.
    Hu, Shiyang
    Maier, Andreas
    Weber, Thomas
    Anton, Gisela
    Michel, Thilo
    Riess, Christian P.
    PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2014, 111 (35) : 12699 - 12704
  • [27] Optimization of in vivo murine X-ray dark-field computed tomography
    Umkehrer, Stephan
    Birnbacher, Lorenz
    Burkhardt, Rico
    von Teuffenbach, Maximilian
    Yildirim, Ali Onder
    Pfeiffer, Daniela
    Herzen, Julia
    Pfeiffer, Franz
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2019, 90 (10):
  • [28] Comparison of Thermal Neutron and Hard X-ray Dark-Field Tomography
    Gustschin, Alex
    Neuwirth, Tobias
    Backs, Alexander
    Viermetz, Manuel
    Gustschin, Nikolai
    Schulz, Michael
    Pfeiffer, Franz
    JOURNAL OF IMAGING, 2021, 7 (01)
  • [29] Directional x-ray dark-field imaging
    Jensen, Torben H.
    Bech, Martin
    Bunk, Oliver
    Donath, Tilman
    David, Christian
    Feidenhans'i, Robert
    Pfeiffer, Franz
    PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (12): : 3317 - 3323
  • [30] Laboratory-based x-ray dark-field microscopy
    Esposito, Michela
    Buchanan, Ian
    Massimi, Lorenzo
    Ferrara, Joseph D.
    Shearing, Paul R.
    Olivo, Alessandro
    Endrizzi, Marco
    PHYSICAL REVIEW APPLIED, 2023, 20 (06):