Speckle-Based X-Ray Dark-Field Tomography of an Attenuating Object

被引:3
|
作者
Alloo, S. J. [1 ]
Paganin, D. M. [2 ]
Morgan, K. S. [2 ]
Kitchen, M. J. [2 ]
Stevenson, A. W. [3 ]
Mayo, S. C. [4 ]
Li, H. T. [5 ]
Kennedy, B. M. [6 ]
Maksimenko, A. [3 ]
Bowden, J. [4 ]
Pavlov, K. M. [1 ,2 ,7 ]
机构
[1] Univ Canterbury, Sch Phys & Chem Sci, Christchurch 8041, New Zealand
[2] Monash Univ, Sch Phys & Astron, Clayton, Vic 3800, Australia
[3] Australian Synchrotron, ANSTO, Clayton, Vic 3168, Australia
[4] Commonwealth Sci & Ind Res Org, Clayton, Vic 3168, Australia
[5] Univ Canterbury, Sch Math, Christchurch 8041, New Zealand
[6] Univ Canterbury, Sch Earth & Environm, Christchurch 8041, New Zealand
[7] Univ New England, Armidale, NSW 2351, Australia
来源
基金
澳大利亚研究理事会;
关键词
Speckle-Based X-Ray Imaging; Phase-Contrast Imaging; Dark-Field Imaging; Computed Tomography; PHASE-CONTRAST; COMPUTED-TOMOGRAPHY; IMAGE; RETRIEVAL;
D O I
10.1117/12.2597722
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Spatial resolution in standard phase-contrast X-ray imaging is limited by the finite number and size of detector pixels. This limits the size of features that can be seen directly in projection images or tomographic reconstructions. Dark-field imaging allows information regarding such features to be obtained, as the reconstructed image is a measure of the position-dependent small-angle X-ray scattering of incident rays from the unresolved microstructure. In this paper we utilize an intrinsic speckle-tracking-based X-ray imaging technique to obtain the effective dark-field signal from a wood sample. This effective dark-field signal is extracted using a Fokker-Planck type formalism, which models the deformations of illuminating reference-beam speckles due to both coherent and diffusive scatter from the sample. We here assume that (a) small-angle scattering fans at the exit surface of the sample are rotationally symmetric, and (b) the object has both attenuating and refractive properties. The associated inverse problem, of extracting the effective dark-field signal, is numerically stabilised using a \weighted determinants" approach. Effective dark-field projection images are presented, as well as the dark-field tomographic reconstructions obtained using Fokker-Planck implicit speckle-tracking.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Artifacts in X-ray dark-field measurements
    Horn, Florian
    Bayer, Florian
    Goedel, Karl
    Haas, Wilhelm
    Pelzer, Georg
    Rieger, Jens
    Ritter, Andre
    Weber, Thomas
    Zang, Andrea
    Durst, Juergen
    Michel, Thilo
    Anton, Gisela
    MEDICAL IMAGING 2013: PHYSICS OF MEDICAL IMAGING, 2013, 8668
  • [32] Dark-field hyperspectral X-ray imaging
    Egan, Christopher K.
    Jacques, Simon D. M.
    Connolley, Thomas
    Wilson, Matthew D.
    Veale, Matthew C.
    Seller, Paul
    Cernik, Robert J.
    PROCEEDINGS OF THE ROYAL SOCIETY A-MATHEMATICAL PHYSICAL AND ENGINEERING SCIENCES, 2014, 470 (2165):
  • [33] X-ray dark-field imaging modeling
    Cong, W.
    Pfeiffer, F.
    Bech, M.
    Wang, G.
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2012, 29 (06) : 908 - 912
  • [34] Hybrid dark-field and attenuation contrast retrieval for laboratory-based X-ray tomography
    Doherty, Adam
    Buchanan, Ian
    Roche I Morgo, Oriol
    Astolfo, Alberto
    Savvidis, Savvas
    Gerli, Mattia F. M.
    Citro, Antonio
    Olivo, Alessandro
    Endrizzi, Marco
    OPTICA, 2024, 11 (12): : 1603 - 1613
  • [35] TOWARDS QUANTIFICATION OF KIDNEY STONES USING X-RAY DARK-FIELD TOMOGRAPHY
    Hu, S.
    Yang, F.
    Griffa, M.
    Kaufmann, R.
    Anton, G.
    Maier, A.
    Riess, C.
    2017 IEEE 14TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI 2017), 2017, : 1112 - 1115
  • [36] Task-driven Acquisition in Anisotropic X-ray Dark-Field Tomography
    Boghiu, Theodor Cheslerean
    Pfeiffer, Franz
    Lasser, Tobias
    15TH INTERNATIONAL MEETING ON FULLY THREE-DIMENSIONAL IMAGE RECONSTRUCTION IN RADIOLOGY AND NUCLEAR MEDICINE, 2019, 11072
  • [37] X-ray dark-field tomography of fresh biological samples with the grating interferometry
    Jiang, Xiaolei
    Zhang, Li
    Zhang, Ran
    Zhu, Xiaohua
    2014 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2014,
  • [38] X-ray phase and dark-field computed tomography without optical elements
    Eatham, T. homas a. l
    Aganin, D. avid m. p
    Organ, K. aye s. m
    OPTICS EXPRESS, 2024, 32 (03): : 4588 - 4602
  • [39] X-ray dark-field computed tomography using a grating interferometer setup
    Bevins, Nicholas
    Zambelli, Joseph
    Qi, Zhihua
    Chen, Guang-Hong
    MEDICAL IMAGING 2010: PHYSICS OF MEDICAL IMAGING, 2010, 7622
  • [40] Robust dark-field signal extraction for modulation-based x-ray tensor tomography
    Lautizi, Ginevra
    Di Trapani, Vittorio
    Studer, Alain
    Zdora, Marie-Christine
    De Marco, Fabio
    Kim, Jisoo
    Marone, Federica
    Stampanoni, Marco
    Thibault, Pierre
    APPLIED PHYSICS LETTERS, 2024, 125 (26)