Evaluation of crystalline lens and Chock for intraocular lens tilt using a swept-source optical coherence tomography biometer

被引:55
|
作者
Wang, Li [1 ]
de Souza, Rodrigo Guimaraes [1 ]
Weikert, Mitchell P. [1 ]
Koch, Douglas D. [1 ]
机构
[1] Baylor Coll Med, Cullen Eye Inst, 6565 Fannin,NC 205, Houston, TX 77030 USA
来源
关键词
DECENTRATION; 1-PIECE;
D O I
10.1016/j.jcrs.2018.08.025
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate crystalline lens and intraocular lens (IOL) tilt using a swept-source optical coherence tomography (SS-OCT) biometer (IOLMaster 700). Setting: Cullen Eye Institute, Baylor College of Medicine, Houston, Texas, USA. Design: Retrospective case series. Methods: The study patients were evaluated for 1) repeatability of the crystalline lens tilt measurement, 2) preoperative crystalline lens and postoperative IOL tilt in right eyes, 3) mirror symmetry between right eyes and left eyes, 4) the correlation between preoperative crystalline lens and postoperative IOL tilt, and 5) the correlation between the magnitude of lens tilt and ocular parameters. Results: The study comprised 333 patients. The repeatability was 0.1 degrees for tilt magnitude and 3.0 degrees for tilt direction. Both the crystalline lens and IOL had anterior tilt of the nasal portion with mean tilt magnitudes of 3.7 degrees +/- 1.1 (SD) (range 0.4 to 6.9 degrees) for the crystalline lens and 4.9 +/- 1.8 degrees (range 1.6 to 10.7 degrees) for the IOL. There was mirror symmetry between right eyes and left eyes. The mean IOL tilt magnitude exceeded crystalline lens tilt by 1.2 +/- 1.1 degrees (range -3.2 to 4.0 degrees), and the 2 values were significantly correlated (all P < .01). The magnitude of crystalline lens tilt significantly increased with decreasing axial length and with increasing angle alpha (all P < .05). Conclusions: The repeatability of crystalline lens tilt measurements using the SS-OCT biometer was excellent. There was mirror symmetry between the right eyes and left eyes. Preoperative crystalline lens tilt could be used to predict the postoperative IOL tilt. The lens tilt magnitude was greater in short eyes and in eyes with larger angle alpha. (C) 2018 ASCRS and ESCRS
引用
收藏
页码:35 / 40
页数:6
相关论文
共 50 条
  • [41] Accuracy of the VRF and VRF-G Intraocular Lens Power Calculation Formulas Using Swept-Source Optical Coherence Tomography Biometry
    Voytsekhivskyy, Oleksiy V.
    CLINICAL OPHTHALMOLOGY, 2023, 17 : 3663 - 3672
  • [42] Repeatability and reproducibility of a new spectral-domain optical coherence tomography biometer and agreement with swept-source optical coherence tomography based biometer
    Li, Xin
    Lei, Chak Seng
    Ning, Rui
    Liu, Luze
    Chen, Aodong
    Yang, Xinning
    Savini, Giacomo
    Schiano-Lomoriello, Domenico
    Zhou, Xingtao
    Huang, Jinhai
    EYE AND VISION, 2025, 12 (01)
  • [43] Accuracy of Swept-Source Optical Coherence Tomography and Ultrasound Biomicroscopy for Evaluation of Posterior Lens Capsule in Traumatic Cataract
    Tabatabaei, Seyed Ali
    Soleimani, Mohammad
    Etesali, Hamed
    Naderan, Morteza
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2020, 216 : 55 - 58
  • [44] Effect of Temporal Decentration of Orthokeratologic Lens on Corneal Aberrations in Swept-source Optical Coherence Tomography
    Heo, Jung Sun
    Moon, Nam Ju
    Kim, Kyoung Woo
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2024, 65 (05): : 309 - 319
  • [45] Evaluation of Vitreous Cells Using Swept-Source Optical Coherence Tomography
    Choi, Rene
    Li, Yan
    Siak, Jay Jyh-Kuen
    Lu, Chen
    Lee, ByungKun
    Yang, Jianlong
    Liu, Gangjun
    Suhler, Eric B.
    Lin, Phoebe
    Fujimoto, James G.
    Rosenbaum, James T.
    Huang, David
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)
  • [46] Accuracy of swept-source optical coherence tomography based biometry for intraocular lens power calculation: a retrospective cross–sectional study
    Youngju An
    Eun-Kyoung Kang
    Hyojin Kim
    Min-Ji Kang
    Yong-Soo Byun
    Choun-Ki Joo
    BMC Ophthalmology, 19
  • [47] Assessment of tilt and decentration of crystalline lens and intraocular lens relative to the corneal topographic axis using anterior segment optical coherence tomography
    Kimura, Shuhei
    Morizane, Yuki
    Shiode, Yusuke
    Hirano, Masayuki
    Doi, Shinichiro
    Toshima, Shinji
    Fujiwara, Atsushi
    Shiraga, Fumio
    PLOS ONE, 2017, 12 (09):
  • [48] Comparison of two biometers: A swept-source optical coherence tomography and an optical low-coherence reflectometry biometer
    El Chehab, Hussam
    Agard, Emilie
    Dot, Corinne
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2019, 29 (05) : 547 - 554
  • [49] Comparison of Clinical Outcomes between Swept-source Optical Coherence Tomography Biometer and Partial Coherence Interferometer
    Jang, Mirinae
    Lee, Hye Jin
    Lee, Sang-Yoon
    Kim, Jin Young
    Ma, Dae Joong
    Jeong, Jin Ho
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2020, 61 (08): : 905 - 910
  • [50] Comparison of various intraocular lens formulas using a new high-resolution swept-source optical coherence tomographer
    Szalai, Eszter
    Toth, Noemi
    Kolkedi, Zsofia
    Varga, Csaba
    Csutak, Adrienne
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2020, 46 (08): : 1138 - 1141