Accuracy of the VRF and VRF-G Intraocular Lens Power Calculation Formulas Using Swept-Source Optical Coherence Tomography Biometry

被引:2
|
作者
Voytsekhivskyy, Oleksiy V. [1 ]
机构
[1] Kyiv Clin Ophthalmol Hosp Eye Microsurg Ctr, Komarov Ave 3, UA-03680 Kiev, Ukraine
来源
CLINICAL OPHTHALMOLOGY | 2023年 / 17卷
关键词
IOL power; VRF formula; calculation; formulas; IOLMaster; axial length; PREDICTION ACCURACY; IOL CALCULATION;
D O I
10.2147/OPTH.S439287
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To collate the accuracy of two recently introduced intraocular lens (IOL) formulas (VRF and VRF-G) in cataract patients using a swept-source optical coherence tomography (SS-OCT) biometry (IOL Master 700, Carl Zeiss Meditec AG, Jena, Germany). Patients and Methods: Data records of 295 eyes from 295 patients were included in this scrutiny. The IOLMaster 700 SS-OCT biometer was used for biometric measurements. The VRF and VRF-G formulas were compared with seven 3rd and 4th generation thin and thick-lens formulas: Haigis, Hoffer Q, Holladay 1, Holladay 2, SRK/T, T2, and Barrett Universal II. With optimized lens constants, the mean prediction error (PE) and its standard deviation (SD), the median absolute error (MedAE), the mean absolute error (MAE), and the percentage of eyes with PEs within +/- 0.25 D, +/- 0.50 D, +/- 0.75 D, +/- 1.00 D, and <+/- 2.00 D were analyzed.Results: Statistically significant differences were found between formulas in the whole group (Friedman test, P = 0.000). The VRF-G and Haigis formulas showed the lowest SD values (0.464 D and 0.466 D respectively). The VRF and Barrett Universal II formulas were less predictable (SD 0.471 D and SD 0.474 D respectively). The biggest proportion of eyes within +/- 0.50 D was found with VRF-G (76.27%), Haigis (75.59%), VRF (74.92%), and Barrett Universal II (74.92%) formulas.Conclusion: Based on data achieved from the SS-OCT biometry, the VRF-G and Haigis methods were the more precise predictors of postoperative refraction with the biggest proportion of eyes within +/- 0.50 D.
引用
收藏
页码:3663 / 3672
页数:10
相关论文
共 50 条
  • [1] Accuracy of intraocular lens power calculation formulas using a swept-source optical biometer
    Kim, Se Young
    Lee, Seung Hyun
    Kim, Na Rae
    Chin, Hee Seung
    Jung, Ji Won
    PLOS ONE, 2020, 15 (01):
  • [2] VRF-G, a New Intraocular Lens Power Calculation Formula: A 13-Formulas Comparison Study
    Hipolito-Fernandes, Diogo
    Luis, Maria Elisa
    Gil, Pedro
    Maduro, Vitor
    Feijao, Joao
    Yeo, Tun Kuan
    Voytsekhivskyy, Oleksiy
    Alves, Nuno
    CLINICAL OPHTHALMOLOGY, 2020, 14 : 4395 - 4402
  • [3] Accuracy of swept-source optical coherence tomography based biometry for intraocular lens power calculation: a retrospective cross–sectional study
    Youngju An
    Eun-Kyoung Kang
    Hyojin Kim
    Min-Ji Kang
    Yong-Soo Byun
    Choun-Ki Joo
    BMC Ophthalmology, 19
  • [4] Predictive accuracy of partial coherence interferometry and swept-source optical coherence tomography for intraocular lens power calculation
    Whang, Woong-Joo
    Yoo, Young-Sik
    Kang, Min-Ji
    Joo, Choun-Ki
    SCIENTIFIC REPORTS, 2018, 8
  • [5] Predictive accuracy of partial coherence interferometry and swept-source optical coherence tomography for intraocular lens power calculation
    Woong-Joo Whang
    Young-Sik Yoo
    Min-Ji Kang
    Choun-Ki Joo
    Scientific Reports, 8
  • [6] Biometry and intraocular power calculation using a swept-source optical coherence tomography: A repeatability and agreement study
    Hashemi, Hassan
    Miraftab, Mohammad
    Panahi, Parsa
    Asgari, Soheila
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2022, 70 (08) : 2845 - 2850
  • [7] Accuracy of swept-source optical coherence tomography based biometry for intraocular lens power calculation: a retrospective cross-sectional study
    An, Youngju
    Kang, Eun-Kyoung
    Kim, Hyojin
    Kang, Min-Ji
    Byun, Yong-Soo
    Joo, Choun-Ki
    BMC OPHTHALMOLOGY, 2019, 19 (1)
  • [8] Comparison of Intraocular Lens Power Prediction Accuracy Between 2 Swept-Source Optical Coherence Tomography Biometry Devices
    Sorkin, Nir
    Zadok, Rotem
    Savini, Giacomo
    Kan-Tor, Yoav
    Benjamini, Yuval
    Levinger, Eliya
    Bardugo, Judith
    Abulafia, Adi
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2024, 265 : 156 - 164
  • [9] Ray Tracing versus Thin-Lens Formulas for IOL Power Calculation Using Swept-Source Optical Coherence Tomography Biometry
    Ghaffari, Reza
    Abdi, Parisa
    Moghaddasi, Alireza
    Heidarzadeh, Somayeh
    Ghahvhechian, Hossein
    Kasiri, Maryam
    JOURNAL OF OPHTHALMIC & VISION RESEARCH, 2022, 17 (02) : 176 - 185
  • [10] Comparison of formula accuracy for intraocular lens power calculation based on measurements by a swept-source optical coherence tomography optical biometer
    Savini, Giacomo
    Hoffer, Kenneth J.
    Balducci, Nicole
    Barboni, Piero
    Schiano-Lomoriello, Domenico
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2020, 46 (01): : 27 - 33