Accuracy of the VRF and VRF-G Intraocular Lens Power Calculation Formulas Using Swept-Source Optical Coherence Tomography Biometry

被引:2
|
作者
Voytsekhivskyy, Oleksiy V. [1 ]
机构
[1] Kyiv Clin Ophthalmol Hosp Eye Microsurg Ctr, Komarov Ave 3, UA-03680 Kiev, Ukraine
来源
CLINICAL OPHTHALMOLOGY | 2023年 / 17卷
关键词
IOL power; VRF formula; calculation; formulas; IOLMaster; axial length; PREDICTION ACCURACY; IOL CALCULATION;
D O I
10.2147/OPTH.S439287
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To collate the accuracy of two recently introduced intraocular lens (IOL) formulas (VRF and VRF-G) in cataract patients using a swept-source optical coherence tomography (SS-OCT) biometry (IOL Master 700, Carl Zeiss Meditec AG, Jena, Germany). Patients and Methods: Data records of 295 eyes from 295 patients were included in this scrutiny. The IOLMaster 700 SS-OCT biometer was used for biometric measurements. The VRF and VRF-G formulas were compared with seven 3rd and 4th generation thin and thick-lens formulas: Haigis, Hoffer Q, Holladay 1, Holladay 2, SRK/T, T2, and Barrett Universal II. With optimized lens constants, the mean prediction error (PE) and its standard deviation (SD), the median absolute error (MedAE), the mean absolute error (MAE), and the percentage of eyes with PEs within +/- 0.25 D, +/- 0.50 D, +/- 0.75 D, +/- 1.00 D, and <+/- 2.00 D were analyzed.Results: Statistically significant differences were found between formulas in the whole group (Friedman test, P = 0.000). The VRF-G and Haigis formulas showed the lowest SD values (0.464 D and 0.466 D respectively). The VRF and Barrett Universal II formulas were less predictable (SD 0.471 D and SD 0.474 D respectively). The biggest proportion of eyes within +/- 0.50 D was found with VRF-G (76.27%), Haigis (75.59%), VRF (74.92%), and Barrett Universal II (74.92%) formulas.Conclusion: Based on data achieved from the SS-OCT biometry, the VRF-G and Haigis methods were the more precise predictors of postoperative refraction with the biggest proportion of eyes within +/- 0.50 D.
引用
收藏
页码:3663 / 3672
页数:10
相关论文
共 50 条
  • [21] Crystalline lens power and astigmatism calculation in myopia by swept-source optical coherence tomography: A pilot study
    Wang, Shulin
    Cheng, Dan
    Zhu, Xueying
    Bao, Fangjun
    Zhu, Jun
    Pang, Chenjiu
    Ye, Yufeng
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2025,
  • [22] Evaluation of Refractive Predictive Accuracy in Intraocular Lens Power Calculations: A Comparative Study of Swept-Source Optical Coherence Tomography and Optical Low-Coherence Interferometry
    Al Barri, Leila
    Mercea, Nadina
    Ionela-Iasmina, Yasar
    Munteanu, Mihnea
    Stanca, Horia T.
    JOURNAL OF CLINICAL MEDICINE, 2025, 14 (04)
  • [23] Detecting macular disease with a biometry device using swept-source optical coherence tomography
    Tan, Colin S.
    Cheong, Kai Xiong
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (10): : 1544 - 1545
  • [24] Prediction accuracy of standard and total keratometry by swept-source optical biometer for multifocal intraocular lens power calculation
    Hun Lee
    Jae Lim Chung
    Young Jun Kim
    Jae Yong Kim
    Hungwon Tchah
    Scientific Reports, 11
  • [25] Prediction accuracy of standard and total keratometry by swept-source optical biometer for multifocal intraocular lens power calculation
    Lee, Hun
    Chung, Jae Lim
    Kim, Young Jun
    Kim, Jae Yong
    Tchah, Hungwon
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [26] Total keratometry for toric intraocular lens calculation: comparison from two swept-source optical coherence tomography biometers
    Chai, Feiyan
    Ma, Jack X.
    Wang, Xiaogang
    Liu, Jiewei
    Jiang, Lin
    Wu, Wanmin
    Li, Junhong
    FRONTIERS IN MEDICINE, 2024, 10
  • [27] Stability of Intraocular Lens With Different Haptic Design: A Swept-Source Optical Coherence Tomography Study
    Xiao, Zixuan
    Wang, Geng
    Zhen, Miaoru
    Zhao, Zifeng
    FRONTIERS IN MEDICINE, 2021, 8
  • [28] Laser Lens Size Measurement Using Swept-Source Optical Coherence Tomography
    Jia, Pingping
    Zhao, Hong
    Qin, Yuwei
    APPLIED SCIENCES-BASEL, 2020, 10 (14):
  • [29] Swept-Source Optical Coherence Tomography-Based Biometry: A Comprehensive Overview
    Borgia, Alfredo
    Raimondi, Raffaele
    Sorrentino, Tania
    Santoru, Francesco
    Buzzi, Matilde
    Borgia, Vittorio
    Scorcia, Vincenzo
    Giannaccare, Giuseppe
    PHOTONICS, 2022, 9 (12)
  • [30] Comparison of various intraocular lens formulas using a new high-resolution swept-source optical coherence tomographer
    Szalai, Eszter
    Toth, Noemi
    Kolkedi, Zsofia
    Varga, Csaba
    Csutak, Adrienne
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2020, 46 (08): : 1138 - 1141