Evaluation of crystalline lens and Chock for intraocular lens tilt using a swept-source optical coherence tomography biometer

被引:55
|
作者
Wang, Li [1 ]
de Souza, Rodrigo Guimaraes [1 ]
Weikert, Mitchell P. [1 ]
Koch, Douglas D. [1 ]
机构
[1] Baylor Coll Med, Cullen Eye Inst, 6565 Fannin,NC 205, Houston, TX 77030 USA
来源
关键词
DECENTRATION; 1-PIECE;
D O I
10.1016/j.jcrs.2018.08.025
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate crystalline lens and intraocular lens (IOL) tilt using a swept-source optical coherence tomography (SS-OCT) biometer (IOLMaster 700). Setting: Cullen Eye Institute, Baylor College of Medicine, Houston, Texas, USA. Design: Retrospective case series. Methods: The study patients were evaluated for 1) repeatability of the crystalline lens tilt measurement, 2) preoperative crystalline lens and postoperative IOL tilt in right eyes, 3) mirror symmetry between right eyes and left eyes, 4) the correlation between preoperative crystalline lens and postoperative IOL tilt, and 5) the correlation between the magnitude of lens tilt and ocular parameters. Results: The study comprised 333 patients. The repeatability was 0.1 degrees for tilt magnitude and 3.0 degrees for tilt direction. Both the crystalline lens and IOL had anterior tilt of the nasal portion with mean tilt magnitudes of 3.7 degrees +/- 1.1 (SD) (range 0.4 to 6.9 degrees) for the crystalline lens and 4.9 +/- 1.8 degrees (range 1.6 to 10.7 degrees) for the IOL. There was mirror symmetry between right eyes and left eyes. The mean IOL tilt magnitude exceeded crystalline lens tilt by 1.2 +/- 1.1 degrees (range -3.2 to 4.0 degrees), and the 2 values were significantly correlated (all P < .01). The magnitude of crystalline lens tilt significantly increased with decreasing axial length and with increasing angle alpha (all P < .05). Conclusions: The repeatability of crystalline lens tilt measurements using the SS-OCT biometer was excellent. There was mirror symmetry between the right eyes and left eyes. Preoperative crystalline lens tilt could be used to predict the postoperative IOL tilt. The lens tilt magnitude was greater in short eyes and in eyes with larger angle alpha. (C) 2018 ASCRS and ESCRS
引用
收藏
页码:35 / 40
页数:6
相关论文
共 50 条
  • [11] Laser Lens Size Measurement Using Swept-Source Optical Coherence Tomography
    Jia, Pingping
    Zhao, Hong
    Qin, Yuwei
    APPLIED SCIENCES-BASEL, 2020, 10 (14):
  • [12] Stability of Intraocular Lens With Different Haptic Design: A Swept-Source Optical Coherence Tomography Study
    Xiao, Zixuan
    Wang, Geng
    Zhen, Miaoru
    Zhao, Zifeng
    FRONTIERS IN MEDICINE, 2021, 8
  • [13] Impact and Correction of an Anterior Phakic Intraocular Lens on Swept-Source Optical Coherence Tomography Biometry
    Ribeiro, Bruno Barbosa
    Monteiro, Silvia
    Marques, Joao Heitor
    Abreu, Ana Carolina
    Pinto, Maria do Ceu
    JOURNAL OF REFRACTIVE SURGERY, 2024, 40 (08) : e562 - e568
  • [14] Efficacy of Biometry Using Swept-source Optical Coherence Tomography for Posterior Chamber Phakic Intraocular Lens Implantation
    Jo, Min Soo
    Moon, Ja Yoon
    Chung, Sung Kun
    Kim, Eung Kweon
    Park, Kyu Hong
    Choi, Jin Seok
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2023, 64 (05): : 374 - 381
  • [15] Three-Dimensional Cataract Crystalline Lens Imaging With Swept-Source Optical Coherence Tomography
    de Castro, Alberto
    Benito, Antonio
    Manzanera, Silvestre
    Mompean, Juan
    Canizares, Belen
    Martinez, David
    Maria Marin, Jose
    Grulkowski, Ireneusz
    Artal, Pablo
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (02) : 897 - 903
  • [16] Predictive accuracy of partial coherence interferometry and swept-source optical coherence tomography for intraocular lens power calculation
    Whang, Woong-Joo
    Yoo, Young-Sik
    Kang, Min-Ji
    Joo, Choun-Ki
    SCIENTIFIC REPORTS, 2018, 8
  • [17] Three-Dimensional Reconstruction and Swept-Source Optical Coherence Tomography for Crystalline Lens Tilt and Decentration Relative to the Corneal Vertex
    Dong, Jing
    Wang, Xiao-Liang
    Deng, Minghui
    Wang, Xiao-Gang
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2021, 10 (09):
  • [18] Predictive accuracy of partial coherence interferometry and swept-source optical coherence tomography for intraocular lens power calculation
    Woong-Joo Whang
    Young-Sik Yoo
    Min-Ji Kang
    Choun-Ki Joo
    Scientific Reports, 8
  • [19] Comparison of a new optical biometer using swept-source optical coherence tomography and a biometer using optical low-coherence reflectometry
    Hoffer, Kenneth J.
    Hoffmann, Peter C.
    Savini, Giacomo
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (08): : 1165 - 1172
  • [20] Comparison of a new biometer using swept-source optical coherence tomography and a conventional biometer using partial coherence interferometry
    Higashiyama, Tomoaki
    Mori, Hazuki
    Nakajima, Fumi
    Ohji, Masahito
    PLOS ONE, 2018, 13 (04):