A Parametric Model for the Measurement of Linear Magnitudes in Non-Contact CMM

被引:0
|
作者
Vazquez, J. M. [1 ]
Garcia, D. [1 ]
Garofano, J. E. [1 ]
Contreras, J. P. [1 ]
Marcos, M. [1 ]
机构
[1] Univ Cadiz, Fac Engn, Ind Metrol Ctr, Cadiz 11002, Spain
关键词
Non Contact CMM; Linear Magnitudes; Parametric Model; Regression;
D O I
10.1063/1.4707561
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Research work has been carried out to determine an approach to a relationship that made possible to the most suitable configuration for non-contact coordinate measure machines (CMM) in order to obtain high quality measurements of linear magnitudes. This paper describes the development of a parametric model between the optical magnification, the length of samples and the values obtained of correction and uncertainty of the measures. For this purpose, an experimental methodology has been designed for obtaining on the most appropriate conditions the data that will be subject of this work. The experimental results indicate that the optical amplification and the length of the sample are the most significant factors affecting the uncertainty of the measures. The model presented in this paper has been determined through approximations to multivariate regression expressions and can be great assistance in the choice of the most appropriate input parameters to setup the measurement device.
引用
收藏
页码:151 / 157
页数:7
相关论文
共 50 条
  • [31] A non-contact measurement of the roughness of textile fabrics
    Bueno, MA
    Durand, B
    Renner, M
    EXPERIMENTAL TECHNIQUES, 2000, 24 (02) : 23 - 27
  • [32] A micro sensor for non-contact temperature measurement
    Li, XP
    Chan, WF
    MICROMACHINING AND MICROFABRICATION, 2000, 4230 : 66 - 75
  • [33] Balanced Non-contact Connector for PIM Measurement
    Murofushi, Ryunosuke
    Kuga, Nobuhiro
    Hanayama, Eiji
    2020 INTERNATIONAL SYMPOSIUM ON ANTENNAS AND PROPAGATION (ISAP), 2021, : 197 - 198
  • [34] NON-CONTACT MEASUREMENT OF SCULPTURED SURFACE OF ROTATION
    Zhang GuoxiongLiu ShuguiQiu ZurongYu FushengNaYonglinLeng ChanglinState Key Laboratory of PrecisionMeasuring Technology and Instruments
    Chinese Journal of Mechanical Engineering, 2004, (04) : 571 - 574
  • [35] Non-contact measurement of thermal diffusivity in tissue
    Telenkov, SA
    Youn, JI
    Goodman, DM
    Welch, AJ
    Milner, TE
    PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (02): : 551 - 558
  • [36] Non-contact speed measurement of solid surfaces
    Engelberg, T.
    Vom Stein, D.
    Zeitler, R.
    Technisches Messen TM, 64 (10):
  • [37] Non-contact OEM color measurement with JENCOLOR
    不详
    SENSOR REVIEW, 2010, 30 (01) : 80 - 81
  • [38] Non-contact measurement of damaged external tapered thread based on linear array CCD
    He, F. J.
    Zhang, R. J.
    Du, Z. J.
    Cui, X. M.
    4TH INTERNATIONAL SYMPOSIUM ON INSTRUMENTATION SCIENCE AND TECHNOLOGY (ISIST' 2006), 2006, 48 : 676 - 680
  • [39] Contact and non-contact ultrasonic measurement in the food industry: a review
    Khairi, Mohd Taufiq Mohd
    Ibrahim, Sallehuddin
    Yunus, Mohd Amri Md
    Faramarzi, Mahdi
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2016, 27 (01)
  • [40] Non-contact multiband method for emissivity measurement
    Mazikowski, A
    Chrzanowski, K
    INFRARED PHYSICS & TECHNOLOGY, 2003, 44 (02) : 91 - 99