A Parametric Model for the Measurement of Linear Magnitudes in Non-Contact CMM

被引:0
|
作者
Vazquez, J. M. [1 ]
Garcia, D. [1 ]
Garofano, J. E. [1 ]
Contreras, J. P. [1 ]
Marcos, M. [1 ]
机构
[1] Univ Cadiz, Fac Engn, Ind Metrol Ctr, Cadiz 11002, Spain
关键词
Non Contact CMM; Linear Magnitudes; Parametric Model; Regression;
D O I
10.1063/1.4707561
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Research work has been carried out to determine an approach to a relationship that made possible to the most suitable configuration for non-contact coordinate measure machines (CMM) in order to obtain high quality measurements of linear magnitudes. This paper describes the development of a parametric model between the optical magnification, the length of samples and the values obtained of correction and uncertainty of the measures. For this purpose, an experimental methodology has been designed for obtaining on the most appropriate conditions the data that will be subject of this work. The experimental results indicate that the optical amplification and the length of the sample are the most significant factors affecting the uncertainty of the measures. The model presented in this paper has been determined through approximations to multivariate regression expressions and can be great assistance in the choice of the most appropriate input parameters to setup the measurement device.
引用
收藏
页码:151 / 157
页数:7
相关论文
共 50 条
  • [21] Non-contact coating thickness measurement
    Chandler, PE
    Quigley, MBC
    Fletcher, JF
    THERMAL SPRAY, VOLS 1 AND 2: MEETING THE CHALLENGES OF THE 21ST CENTURY, 1998, : 875 - 879
  • [22] NON-CONTACT CURRENT AND POTENTIAL MEASUREMENT
    SWAIN, WH
    PIPELINE & GAS JOURNAL, 1983, 210 (02) : 28 - &
  • [23] NON-CONTACT LENGTH AND SPEED MEASUREMENT
    Storozhuk, E. S.
    Redko, V. V.
    Mylnikova, T. S.
    PROCEEDINGS OF THE 2008 INTERNATIONAL CONFERENCE MODERN TECHNIQUE AND TECHNOLOGIES, 2008, : 48 - 52
  • [24] Non-contact endoscopic temperature measurement
    Vilches, Sergio
    Ataman, Caglar
    Zappe, Hans
    OPTICAL FIBERS AND SENSORS FOR MEDICAL DIAGNOSTICS AND TREATMENT APPLICATIONS XX, 2020, 11233
  • [25] AUTOMATIC NON-CONTACT SHAFT MEASUREMENT
    DASSLER, HU
    WERKSTATTSTECHNIK ZEITSCHRIFT FUR INDUSTRIELLE FERTIGUNG, 1988, 78 (10): : 583 - 587
  • [26] Non-contact uplift measurement at overhead contact lines
    Hietzge, Jochen
    Stephan, Arnd
    eb - Elektrische Bahnen, 2007, 105 (4-5): : 276 - 279
  • [27] Equivalent Probe Model of Non-contact Measurement for Near-field
    Hung, Tzu-Wen
    Peng, Hsing-Chuan
    Wu, Sung-Mao
    2021 IEEE INTERNATIONAL SYMPOSIUM ON RADIO-FREQUENCY INTEGRATION TECHNOLOGY (RFIT), 2021,
  • [28] Luminance Prediction of Paper Model Surface Based on Non-Contact Measurement
    Li, Xiaozhou
    Han, Xiaomeng
    Liu, Jingjing
    Li, Xuelin
    Cui, Mingming
    Wu, Guangyuan
    TEHNICKI VJESNIK-TECHNICAL GAZETTE, 2021, 28 (04): : 1331 - 1337
  • [29] Displacement measurement of derrick model base on the non-contact type video measurement technology
    Xu Xiaobing
    Han Xing
    Yu Li
    2013 INTERNATIONAL CONFERENCE ON MACHINERY, MATERIALS SCIENCE AND ENERGY ENGINEERING, 2013, 318 : 125 - 129
  • [30] Non-contact linear slider for cryogenic environment
    Perez-Diaz, Jose-Luis
    Carlos Garcia-Prada, Juan
    Diez-Jimenez, Efren
    Valiente-Blanco, Ignacio
    Sander, Berit
    Timm, Lauri
    Sanchez-Garcia-Casarrubios, Juan
    Serrano, Javier
    Romera, Fernando
    Argelaguet-Vilaseca, Heribert
    Gonzalez-de-Maria, David
    MECHANISM AND MACHINE THEORY, 2012, 49 : 308 - 314