The final follow-up plain radiograph is sufficient for clinical evaluation of polyethylene wear in total hip arthroplasty

被引:21
|
作者
Stilling, Maiken [1 ]
Larsen, Kristian [3 ]
Andersen, Niels T. [2 ]
Soballe, Kjeld [1 ]
Kold, Soren [1 ]
Rahbek, Ole [1 ]
机构
[1] Aarhus Univ, Aarhus Univ Hosp, Dept Orthoped, Aarhus, Denmark
[2] Aarhus Univ, Sch Publ Hlth, Dept Biostat, Aarhus, Denmark
[3] Hosp Unit W, Dept Orthoped, Orthoped Res Unit, Holstebro, Denmark
关键词
BACKED ACETABULAR CUPS; MODEL-BASED RSA; FEMORAL-HEAD; MEASUREMENT ACCURACY; TRUE WEAR; PENETRATION; OSTEOLYSIS; REPLACEMENT; ZIRCONIA; COMPONENTS;
D O I
10.3109/17453674.2010.506632
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Methods Measurements of PE wear postoperatively and at final follow-up (after mean 6 years) on plain radiographs of 12 patients after cementless THA were evaluated with PolyWare software and the results were compared with those from RSA as the gold standard (Model-based RSA using elementary geometrical shape models; EGS-RSA). With PolyWare, we either used the final radiographic follow-up (PW1) only or both the postoperative follow-up and the final follow-up (PW2). Results The 2D mean wear measured (in mm) was 0.80, 1.07, and 0.60 for the PW2, PW1, and RSA method. 2D intra-method repeatability was similar for PW1 and RSA with limits of agreement (LOAs, in mm) of +/- 0.22, and +/- 0.23, respectively. 2D inter-method concurrent validity was best between PW1 and EGS-RSA with LOAs of +/- 0.55. For 2D linear wear measurements, the PW1 method had a clinical repeatability similar to that of RSA. Interpretation PW1 is sufficient for retrospective determination of 2D wear from medium-term wear measurements above 0.5 mm, It alleviates the need for baseline plain radiographs, has a clinical precision similar to that of RSA, and is easy and inexpensive to use.
引用
收藏
页码:570 / 578
页数:9
相关论文
共 50 条
  • [41] Five Year Follow-up of One Stage Bilateral Total Hip Arthroplasty
    Tai, C. C.
    Abbas, A. A.
    Varaprasad, M.
    Choon, S. K.
    MALAYSIAN ORTHOPAEDIC JOURNAL, 2007, 1 (01) : 22 - 25
  • [42] Empirical support for radiographic review: a follow-up study of total hip arthroplasty
    Smith, Lindsay K.
    Cramp, Fiona
    Palmer, Shea
    Coghill, Nikki
    Spencer, Robert F.
    HIP INTERNATIONAL, 2013, 23 (01) : 80 - 86
  • [43] TOTAL HIP-ARTHROPLASTY IN PAGETS-DISEASE - A FOLLOW-UP NOTE
    MCDONALD, DJ
    SIM, FH
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1987, 69A (05): : 766 - 772
  • [44] METALLIC HIP ARTHROPLASTY - A FOLLOW-UP STUDY
    STEIN, AH
    COSTEN, WS
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1961, 43 (06): : 909 - 910
  • [45] Highly cross-linked polyethylene decreases the rate of revision of total hip arthroplasty compared with conventional polyethylene at 13 years' follow-up
    Hanna, S. A.
    Somerville, L.
    McCalden, R. W.
    Naudie, D. D.
    MacDonald, S. J.
    BONE & JOINT JOURNAL, 2016, 98B (01): : 28 - 32
  • [46] A 28-year clinical and radiological follow-up of alumina ceramic-on-crosslinked polyethylene total hip arthroplasty A FOLLOW-UP REPORT AND ANALYSIS OF THE OXIDATION OF A SHELF-AGED ACETABULAR COMPONENT
    Rajpura, A.
    Board, T. N.
    Siney, P. D.
    Jones, H. Wynn
    Williams, S.
    Dabbs, L.
    Wroblewski, B. M.
    BONE & JOINT JOURNAL, 2017, 99B (10): : 1286 - 1289
  • [47] SPHEROCENTRIC ARTHROPLASTY OF THE KNEE - A LONG-TERM AND FINAL FOLLOW-UP EVALUATION
    MATTHEWS, LS
    GOLDSTEIN, SA
    KOLOWICH, PA
    KAUFER, H
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1986, (205) : 58 - 66
  • [48] Ceramic-on-ceramic total hip arthroplasty is superior to metal-on-conventional polyethylene at 20-year follow-up: A randomised clinical trial
    Vendittoli, Pascal-Andre
    Shahin, Maged
    Riviere, Charles
    Barry, Janie
    Lavoie, Pauline
    Duval, Nicolas
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2021, 107 (01)
  • [49] Evaluation of contemporary software methods used to quantify polyethylene wear after total hip arthroplasty
    Collier, MB
    Kraay, MJ
    Rimnac, CM
    Goldberg, VM
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A (12): : 2410 - 2418
  • [50] Patient compliance with clinical follow-up after total joint arthroplasty
    Clohisy, John C.
    Kamath, Ganesh V.
    Byrd, Gregory D.
    Steger-May, Karen
    Wright, Rick W.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2008, 90A (09): : 1848 - 1854