摘要
Methods Measurements of PE wear postoperatively and at final follow-up (after mean 6 years) on plain radiographs of 12 patients after cementless THA were evaluated with PolyWare software and the results were compared with those from RSA as the gold standard (Model-based RSA using elementary geometrical shape models; EGS-RSA). With PolyWare, we either used the final radiographic follow-up (PW1) only or both the postoperative follow-up and the final follow-up (PW2). Results The 2D mean wear measured (in mm) was 0.80, 1.07, and 0.60 for the PW2, PW1, and RSA method. 2D intra-method repeatability was similar for PW1 and RSA with limits of agreement (LOAs, in mm) of +/- 0.22, and +/- 0.23, respectively. 2D inter-method concurrent validity was best between PW1 and EGS-RSA with LOAs of +/- 0.55. For 2D linear wear measurements, the PW1 method had a clinical repeatability similar to that of RSA. Interpretation PW1 is sufficient for retrospective determination of 2D wear from medium-term wear measurements above 0.5 mm, It alleviates the need for baseline plain radiographs, has a clinical precision similar to that of RSA, and is easy and inexpensive to use.
引用
收藏
页码:570 / 578
页数:9
相关论文
共 50 条
  • [31] Crosslinked polyethylene compared to conventional polyethylene in total hip replacement - Pre-clinical evaluation, in-vitro testing and prospective clinical follow-up study
    Geerdink, Carel H.
    Grimm, Bernd
    Ramakrishnan, Rama
    Rondhuis, Jorco
    Verburg, Aart J.
    Tonino, Alphons J.
    ACTA ORTHOPAEDICA, 2006, 77 (05) : 719 - 725
  • [32] In Vivo Measurement of Polyethylene Wear in Cementless Total Hip Arthroplasty
    Roth, A.
    Sander, K.
    Layher, F.
    Babisch, J.
    Venbrocks, R.
    ACTA CHIRURGIAE ORTHOPAEDICAE ET TRAUMATOLOGIAE CECHOSLOVACA, 2010, 77 (01) : 13 - 17
  • [33] Influence of polyethylene creep behavior on wear in total hip arthroplasty
    Penmetsa, JR
    Laz, PJ
    Petrella, AJ
    Rullkoetter, PJ
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2006, 24 (03) : 422 - 427
  • [34] Clinical and functional outcome of total hip arthroplasty in patients with acromegaly: mean twelve year follow-up
    Akkaya, Mustafa
    Pignataro, Antonio
    Sandiford, Nemandra
    Gehrke, Thorsten
    Citak, Mustafa
    INTERNATIONAL ORTHOPAEDICS, 2022, 46 (08) : 1741 - 1747
  • [35] Clinical and functional outcome of total hip arthroplasty in patients with acromegaly: mean twelve year follow-up
    Mustafa Akkaya
    Antonio Pignataro
    Nemandra Sandiford
    Thorsten Gehrke
    Mustafa Citak
    International Orthopaedics, 2022, 46 : 1741 - 1747
  • [36] The NANOS short stem in total hip arthroplasty: a mid term follow-up
    Ettinger, Max
    Ettinger, Peter
    Lerch, Matthias
    Radtke, Kerstin
    Budde, Stefan
    Ezechieli, Marco
    Becher, Christoph
    Thorey, Fritz
    HIP INTERNATIONAL, 2011, 21 (05) : 583 - 586
  • [37] Total hip arthroplasty with the APR stem and cup - Follow-up of a previous report
    Harris, M
    Dorr, LD
    Wan, ZN
    Sirianni, L
    Boutary, M
    JOURNAL OF ARTHROPLASTY, 2005, 20 (07): : 828 - 831
  • [38] Long-term follow-up of total hip arthroplasty using polyethylene-ceramic composite (sandwich) liner
    Rodriguez-Perez, Daniel
    Carnaval, Thiago
    Rodriguez, Marcos-del-Carmen
    Coscujuela-Mana, Antonio
    Agullo, Jose-Luis
    Videla, Sebastian
    HIP INTERNATIONAL, 2024, 34 (04) : 467 - 475
  • [39] Wear Analysis of First-Generation Highly Cross-Linked Polyethylene in Primary Total Hip Arthroplasty An Average 9-Year Follow-Up
    Reynolds, Shaun E.
    Malkani, Arthur L.
    Ramakrishnan, Rama
    Yakkanti, Madhusudhan R.
    JOURNAL OF ARTHROPLASTY, 2012, 27 (06): : 1064 - 1068
  • [40] 10-YEAR FOLLOW-UP OF THE CHARNLEY TOTAL HIP-ARTHROPLASTY
    CEDELL, CA
    SVENDLER, CA
    ACTA ORTHOPAEDICA SCANDINAVICA, 1987, 58 (03): : 308 - 308