The final follow-up plain radiograph is sufficient for clinical evaluation of polyethylene wear in total hip arthroplasty

被引:21
|
作者
Stilling, Maiken [1 ]
Larsen, Kristian [3 ]
Andersen, Niels T. [2 ]
Soballe, Kjeld [1 ]
Kold, Soren [1 ]
Rahbek, Ole [1 ]
机构
[1] Aarhus Univ, Aarhus Univ Hosp, Dept Orthoped, Aarhus, Denmark
[2] Aarhus Univ, Sch Publ Hlth, Dept Biostat, Aarhus, Denmark
[3] Hosp Unit W, Dept Orthoped, Orthoped Res Unit, Holstebro, Denmark
关键词
BACKED ACETABULAR CUPS; MODEL-BASED RSA; FEMORAL-HEAD; MEASUREMENT ACCURACY; TRUE WEAR; PENETRATION; OSTEOLYSIS; REPLACEMENT; ZIRCONIA; COMPONENTS;
D O I
10.3109/17453674.2010.506632
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Methods Measurements of PE wear postoperatively and at final follow-up (after mean 6 years) on plain radiographs of 12 patients after cementless THA were evaluated with PolyWare software and the results were compared with those from RSA as the gold standard (Model-based RSA using elementary geometrical shape models; EGS-RSA). With PolyWare, we either used the final radiographic follow-up (PW1) only or both the postoperative follow-up and the final follow-up (PW2). Results The 2D mean wear measured (in mm) was 0.80, 1.07, and 0.60 for the PW2, PW1, and RSA method. 2D intra-method repeatability was similar for PW1 and RSA with limits of agreement (LOAs, in mm) of +/- 0.22, and +/- 0.23, respectively. 2D inter-method concurrent validity was best between PW1 and EGS-RSA with LOAs of +/- 0.55. For 2D linear wear measurements, the PW1 method had a clinical repeatability similar to that of RSA. Interpretation PW1 is sufficient for retrospective determination of 2D wear from medium-term wear measurements above 0.5 mm, It alleviates the need for baseline plain radiographs, has a clinical precision similar to that of RSA, and is easy and inexpensive to use.
引用
收藏
页码:570 / 578
页数:9
相关论文
共 50 条
  • [21] Guidelines for the follow-up of total hip arthroplasty DO THEY NEED TO BE REVISED?
    Cassidy, R. S.
    hEireamhoin, S. O.
    Beverland, D. E.
    BONE & JOINT JOURNAL, 2019, 101B (05): : 536 - 539
  • [22] Is there a need for routine follow-up after primary total hip arthroplasty?
    Hacking, Craig
    Weinrauch, Patrick
    Whitehouse, Sarah L.
    Crawford, Ross W.
    Donnelly, William J.
    ANZ JOURNAL OF SURGERY, 2010, 80 (10) : 737 - 740
  • [23] TOTAL HIP ARTHROPLASTY - REVIEW OF 333 CASES WITH LONG FOLLOW-UP
    BECKENBAUGH, RD
    ILSTRUP, DM
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1978, 60 (03): : 306 - 313
  • [24] Primary cemented total hip arthroplasty: 10 years follow-up
    Nath, Rajendra
    Gupta, Anil Kumar
    Chakravarty, Unmesh
    Nath, Rohit
    INDIAN JOURNAL OF ORTHOPAEDICS, 2010, 44 (03) : 283 - 288
  • [25] Primary cemented total hip arthroplasty: 10 years follow-up
    Rajendra Nath
    Anil Kumar Gupta
    Unmesh Chakravarty
    Rohit Nath
    Indian Journal of Orthopaedics, 2010, 44 : 283 - 288
  • [26] Metal-on-crosslinked polyethylene in total hip arthroplasty - an excellent combination at fifteen to twenty years of follow-up
    Cheung, Amy
    Chan, Ping Keung
    Fu, Henry
    Cheung, Man Hong
    Chan, Vincent Wai Kwan
    Luk, Michelle Hilda
    Chiu, Kwong-Yuen
    INTERNATIONAL ORTHOPAEDICS, 2023, 47 (10) : 2547 - 2552
  • [27] Metal-on-crosslinked polyethylene in total hip arthroplasty – an excellent combination at fifteen to twenty years of follow-up
    Amy Cheung
    Ping Keung Chan
    Henry Fu
    Man Hong Cheung
    Vincent Wai Kwan Chan
    Michelle Hilda Luk
    Kwong-Yuen Chiu
    International Orthopaedics, 2023, 47 : 2547 - 2552
  • [28] TOTAL HIP-ARTHROPLASTY IN THE ANKYLOSED HIP - A 10-YEAR FOLLOW-UP
    STRATHY, GM
    FITZGERALD, RH
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1988, 70A (07): : 963 - 966
  • [29] Ten-to Sixteen-Year Follow-Up of Highly Cross-Linked Polyethylene in Total Hip Arthroplasty: What Factors Affect Wear?
    Cheung, Amy
    Yan, Chun Hoi
    Fu, Henry
    Cheung, Man Hong
    Chan, Ping Keung
    Chiu, Kwong Yuen
    JOURNAL OF ARTHROPLASTY, 2019, 34 (09): : 2016 - 2021
  • [30] Wear Kinetics of Highly Cross-Linked and Conventional Polyethylene Are Similar at Medium-term Follow-Up After Primary Total Hip Arthroplasty
    Mayer, Constantin
    Rommelmann, Moritz
    Behringer, Michael
    Jaeger, Marcus
    Krauspe, Ruediger
    Zilkens, Christoph
    JOURNAL OF ARTHROPLASTY, 2018, 33 (08): : 2671 - 2676