摘要
Methods Measurements of PE wear postoperatively and at final follow-up (after mean 6 years) on plain radiographs of 12 patients after cementless THA were evaluated with PolyWare software and the results were compared with those from RSA as the gold standard (Model-based RSA using elementary geometrical shape models; EGS-RSA). With PolyWare, we either used the final radiographic follow-up (PW1) only or both the postoperative follow-up and the final follow-up (PW2). Results The 2D mean wear measured (in mm) was 0.80, 1.07, and 0.60 for the PW2, PW1, and RSA method. 2D intra-method repeatability was similar for PW1 and RSA with limits of agreement (LOAs, in mm) of +/- 0.22, and +/- 0.23, respectively. 2D inter-method concurrent validity was best between PW1 and EGS-RSA with LOAs of +/- 0.55. For 2D linear wear measurements, the PW1 method had a clinical repeatability similar to that of RSA. Interpretation PW1 is sufficient for retrospective determination of 2D wear from medium-term wear measurements above 0.5 mm, It alleviates the need for baseline plain radiographs, has a clinical precision similar to that of RSA, and is easy and inexpensive to use.
引用
收藏
页码:570 / 578
页数:9
相关论文
共 50 条
  • [1] Polyethylene wear of the porous-coated anatomic total hip arthroplasty with an average 11-year follow-up
    Kawamura, H
    Bourne, RB
    Dunbar, MJ
    Rorabeck, CH
    JOURNAL OF ARTHROPLASTY, 2001, 16 (08): : 116 - 121
  • [2] Effect of polyethylene wear on osteolysis in cementless primary total hip arthroplasty - Minimal 5-year follow-up study
    Han, CD
    Choe, WS
    Yoo, JH
    JOURNAL OF ARTHROPLASTY, 1999, 14 (06): : 714 - 723
  • [3] Do polyethylene wear particles affect the development of pseudotumor in total hip arthroplasty? A minimum 15-year follow-up
    Ishida, Tsunehito
    Tateiwa, Toshiyuki
    Takahashi, Yasuhito
    Masaoka, Toshinori
    Shishido, Takaaki
    Yamamoto, Kengo
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2023, 18 (01)
  • [4] Do polyethylene wear particles affect the development of pseudotumor in total hip arthroplasty? A minimum 15-year follow-up
    Tsunehito Ishida
    Toshiyuki Tateiwa
    Yasuhito Takahashi
    Toshinori Masaoka
    Takaaki Shishido
    Kengo Yamamoto
    Journal of Orthopaedic Surgery and Research, 18
  • [5] Clinical Outcome, Survival and Polyethylene Wear of an Uncemented Total Hip Arthroplasty A 10-to 12-Year Follow-Up Study of 81 Hips
    Rienstra, Wietske
    van der Veen, Hugo C.
    van den Akker-Scheek, Inge
    van Raay, Jos J. A. M.
    JOURNAL OF ARTHROPLASTY, 2013, 28 (08): : 1362 - 1366
  • [6] POLYETHYLENE WEAR IN TOTAL HIP-ARTHROPLASTY
    BANKSTON, AB
    CATES, H
    RITTER, MA
    KEATING, EM
    FARIS, PM
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1995, (317) : 7 - 13
  • [7] 10-Year Follow-Up Wear Analysis of First-Generation Highly Crosslinked Polyethylene in Primary Total Hip Arthroplasty
    Snir, Nimrod
    Kaye, Ian D.
    Klifto, Christopher S.
    Hamula, Mathew J.
    Wolfson, Theodore S.
    Schwarzkopf, Ran
    Jaffe, Fredrick F.
    JOURNAL OF ARTHROPLASTY, 2014, 29 (03): : 630 - 633
  • [8] 10-Year Follow-Up Wear Analysis of Marathon Highly Cross-Linked Polyethylene in Primary Total Hip Arthroplasty
    Bookman, Jared S.
    Kaye, Ian D.
    Chen, Kevin K.
    Jaffe, Fredrick F.
    Schwarzkopf, Ran
    JOURNAL OF ARTHROPLASTY, 2017, 32 (08): : 2587 - 2589
  • [9] The follow-up posturography in rehabilitation after total hip arthroplasty
    Pethe-Kania, Krystyna
    Opara, Jozef A.
    Kania, Dariusz
    Kidon, Zenon
    Lukaszewicz, Tomasz
    ACTA OF BIOENGINEERING AND BIOMECHANICS, 2017, 19 (01) : 97 - 104
  • [10] Hydrotherapy after total hip arthroplasty: A follow-up study
    Giaquinto, S.
    Ciotola, E.
    Dall'Armi, V.
    Margutti, F.
    ARCHIVES OF GERONTOLOGY AND GERIATRICS, 2010, 50 (01) : 92 - 95