Assessment of right ventricular function by 16-detector-row CT: comparison with magnetic resonance imaging

被引:88
|
作者
Koch, K [1 ]
Oellig, F
Oberholzer, K
Bender, P
Kunz, P
Mildenberger, P
Hake, U
Kreitner, KF
Thelen, M
机构
[1] Univ Mainz, Dept Radiol, D-55131 Mainz, Germany
[2] Univ Mainz, Dept Cardiothorac & Vasc Surg, D-55131 Mainz, Germany
关键词
heart; CT; multidetector-row; function; ventricles; MRI;
D O I
10.1007/s00330-004-2543-6
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this study was to determine right ventricular (RV) function from 16-detector-row CT by using two different software tools in comparison with MRI. Nineteen patients underwent cardiac CT. (1) With semiautomated contour detection software end-diastolic and end-systolic RV volumes were determined from short-axis CT reformations (MPR) created at every 10% of the RR-interval. (2) End-systolic and end-diastolic axial images were transformed to 3D to determine the volumes by using a threshold-supported reconstruction algorithm. Steady-state free-precession cine-MRI of the heart was done in short-axis orientation. RV function could not be analyzed in one patient because of sternal wire artifacts in MRI. Mean end-diastolic (155.4 +/- 54.6 ml) and end-systolic (79.1 +/- 37.0 ml) RV volumes determined with MPR correlated well with MRI [151.9 +/- 53.7 ml (r=0.98) and 75.0 +/- 36.0 ml (r=0.96), respectively (P<0.001)]. RV stroke volume (76.2 +/- 20.2 ml for MPR-CT, 76.9 +/- 20.7 ml for MRI, r=0.93) showed a good correlation and RV ejection fraction (50.8 +/- 8.4% for MPR-CT, 51.9 +/- 7.4% for MRI,)-=0.74) only a moderate one. Threshold supported 3D reconstructions revealed insufficient correlations with MRI (r=0.31-0.59). MPR-based semiautomated analysis of cardiac 16 detector-row CT allows for RV functional analysis. The results correlate well with MRI findings. Threshold value-supported 3D reconstructions did not show satisfying results because of inhomogenelties of RV contrast enhancement.
引用
收藏
页码:312 / 318
页数:7
相关论文
共 50 条
  • [41] Comparison of transthoracic three dimensional echocardiography with magnetic resonance imaging in the assessment of right ventricular volume and mass
    Vogel, M
    Gutberlet, M
    Dittrich, S
    Hosten, N
    Lange, PE
    HEART, 1997, 78 (02) : 127 - 130
  • [42] Comparison of Left Ventricular Function and Mass Assessment on Everyday Echocardiography and Cardiac Magnetic Resonance Imaging
    Lee, Mirae
    Byeon, Kyeongmin
    Kim, Eun Young
    Yang, Jeong Hoon
    Lee, Sungho
    Park, Sung Beom
    Chung, Seungmin
    Park, Jeong-Euy
    Choe, Yeon Hyeon
    Lee, Sang-Chol
    CIRCULATION, 2010, 122 (21)
  • [43] Right ventricular systolic function in hypoplastic left heart syndrome: a comparison of velocity vector imaging and magnetic resonance imaging
    Ruotsalainen, Hanna
    Bellsham-Revell, Hannah
    Bell, Aaron
    Pihkala, Jaana
    Ojala, Tiina
    Simpson, John
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2016, 17 (06) : 687 - 692
  • [44] Assessment of right ventricular function in patients with pulmonary arterial hypertension by speckle tracking imaging and comparison with ejection fraction by cardiac magnetic resonance
    Le Mee, F.
    Renard, S.
    Jacquier, A.
    Gaubert, J. Y.
    Thuny, F.
    Giorgi, R.
    Avierinos, J. F.
    Tafanelli, L.
    Bartoli, J. M.
    Habib, G.
    EUROPEAN HEART JOURNAL, 2008, 29 : 520 - 520
  • [45] Assessment of right-ventricular size and function by real-time three-dimensional echocardiography - comparison with magnetic resonance imaging
    Leibundgut, G.
    Rohner, A.
    Kessel, A.
    Bernheim, A.
    Zellweger, M.
    Buser, P.
    Handke, M.
    EUROPEAN HEART JOURNAL, 2009, 30 : 114 - 114
  • [46] Correlation of right ventricular strain imaging parameters with cardiac magnetic resonance imaging parameters in the assessment of right ventricular function among repaired tetralogy of Fallot patient
    Mandigma, L.
    Azcueta, M. B.
    Sasil, R.
    Mangada, R. C.
    EUROPEAN HEART JOURNAL, 2016, 37 : 856 - 856
  • [47] Magnetic resonance real time imaging of left ventricular function: Comparison with conventional magnetic resonance imaging and echocardiography
    Schalla, S
    Nagel, E
    Lehmkuhl, H
    Klein, C
    Paetsch, I
    Bornstedt, A
    Schnackenburg, B
    Fleck, E
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 35 (02) : 427A - 428A
  • [48] Regional right ventricular function in rats: a novel magnetic resonance imaging method for measurement of right ventricular strain
    Espe, Emil K. S.
    Aronsen, Jan M.
    Norden, Einar S.
    Zhang, Lili
    Sjaastad, Ivar
    AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2020, 318 (01): : H143 - H153
  • [49] Magnetic resonance imaging of right ventricular function after pulmonary autograft surgery
    Carr-White, GS
    Kon, M
    Koh, TW
    Ferdinand, FD
    DeSouza, AC
    Pennell, DJ
    Yacoub, MH
    CIRCULATION, 1998, 98 (17) : 543 - 543
  • [50] RIGHT AND LEFT-VENTRICULAR FUNCTION EVALUATED BY MAGNETIC-RESONANCE IMAGING
    MOGELVANG, J
    KELBAEK, H
    MEHLSEN, J
    BULOW, J
    STUBGAARD, M
    THOMSEN, C
    HENRIKSEN, O
    CLINICAL PHYSIOLOGY, 1988, 8 (01): : 79 - 80