Assessment of right ventricular function by 16-detector-row CT: comparison with magnetic resonance imaging

被引:88
|
作者
Koch, K [1 ]
Oellig, F
Oberholzer, K
Bender, P
Kunz, P
Mildenberger, P
Hake, U
Kreitner, KF
Thelen, M
机构
[1] Univ Mainz, Dept Radiol, D-55131 Mainz, Germany
[2] Univ Mainz, Dept Cardiothorac & Vasc Surg, D-55131 Mainz, Germany
关键词
heart; CT; multidetector-row; function; ventricles; MRI;
D O I
10.1007/s00330-004-2543-6
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this study was to determine right ventricular (RV) function from 16-detector-row CT by using two different software tools in comparison with MRI. Nineteen patients underwent cardiac CT. (1) With semiautomated contour detection software end-diastolic and end-systolic RV volumes were determined from short-axis CT reformations (MPR) created at every 10% of the RR-interval. (2) End-systolic and end-diastolic axial images were transformed to 3D to determine the volumes by using a threshold-supported reconstruction algorithm. Steady-state free-precession cine-MRI of the heart was done in short-axis orientation. RV function could not be analyzed in one patient because of sternal wire artifacts in MRI. Mean end-diastolic (155.4 +/- 54.6 ml) and end-systolic (79.1 +/- 37.0 ml) RV volumes determined with MPR correlated well with MRI [151.9 +/- 53.7 ml (r=0.98) and 75.0 +/- 36.0 ml (r=0.96), respectively (P<0.001)]. RV stroke volume (76.2 +/- 20.2 ml for MPR-CT, 76.9 +/- 20.7 ml for MRI, r=0.93) showed a good correlation and RV ejection fraction (50.8 +/- 8.4% for MPR-CT, 51.9 +/- 7.4% for MRI,)-=0.74) only a moderate one. Threshold supported 3D reconstructions revealed insufficient correlations with MRI (r=0.31-0.59). MPR-based semiautomated analysis of cardiac 16 detector-row CT allows for RV functional analysis. The results correlate well with MRI findings. Threshold value-supported 3D reconstructions did not show satisfying results because of inhomogenelties of RV contrast enhancement.
引用
收藏
页码:312 / 318
页数:7
相关论文
共 50 条
  • [21] Right Ventricular Diastolic Function Evaluation in Magnetic Resonance Imaging
    Kachenoura, Nadjia
    Bollache, Emilie
    Redheuil, Alban
    Clement-Guinaudeau, Stephanie
    Perdrix, Ludivine
    Diebold, Benoit
    Ladouceur, Magalie
    Mousseaux, Elie
    2015 COMPUTING IN CARDIOLOGY CONFERENCE (CINC), 2015, 42 : 89 - 92
  • [22] Impact of right ventricular contrast attenuation on the accuracy of right ventricular function analysis at cardiac multi-detector-row CT
    Aho, Michael R.
    Gebregziabher, Mulugeta
    Schoepf, U. Joseph
    Suranyi, Pal
    Lee, Heon
    Gregg, David
    Costello, Philip
    Zwerner, Peter L.
    EUROPEAN JOURNAL OF RADIOLOGY, 2010, 73 (03) : 560 - 565
  • [23] Electrocardiography-synchronized multi-detector row CT of right ventricular function - Response
    Dogan, Halil
    Kroft, Lucia J. M.
    Huisman, Menno V.
    de Roos, Albert
    RADIOLOGY, 2008, 246 (03) : 987 - 987
  • [24] Automated vs. manual assessment of left ventricular function in cardiac multidetector row computed tomography:: comparison with magnetic resonance imaging
    Mahnken, AH
    Mühlenbruch, G
    Koos, R
    Stanzel, S
    Busch, PS
    Niethammer, M
    Günther, RW
    Wildberger, JE
    EUROPEAN RADIOLOGY, 2006, 16 (07) : 1416 - 1423
  • [25] Automated vs. manual assessment of left ventricular function in cardiac multidetector row computed tomography: comparison with magnetic resonance imaging
    Andreas H. Mahnken
    Georg Mühlenbruch
    Ralf Koos
    Sven Stanzel
    Petra Simone Busch
    Mathias Niethammer
    Rolf W. Günther
    Joachim E. Wildberger
    European Radiology, 2006, 16 : 1416 - 1423
  • [26] Comprehensive assessment of patients after coronary artery bypass grafting by 16-detector-row computed tomography
    Salm, LP
    Bax, JJ
    Jukema, JW
    Schuijf, JD
    Vliegen, HW
    Lamb, HJ
    van der Wall, EE
    de Roos, A
    AMERICAN HEART JOURNAL, 2005, 150 (04) : 775 - 781
  • [27] Value of Speckle Tracking for the Assessment of Right Ventricular Function in Patients Operated on for Tetralogy of Fallot. Comparison with Magnetic Resonance Imaging
    Bernard, Yvette
    Morel, Mathilde
    Descotes-Genon, Vincent
    Jehl, Jerome
    Meneveau, Nicolas
    Schiele, Francois
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2014, 31 (04): : 474 - 482
  • [28] Assessment of regional left ventricular function with multidetector-row computed tomography versus magnetic resonance imaging
    Roman Fischbach
    Kai Uwe Juergens
    Murat Ozgun
    David Maintz
    Matthias Grude
    Harald Seifarth
    Walter Heindel
    Thomas Wichter
    European Radiology, 2007, 17 : 1009 - 1017
  • [29] Assessment of regional left ventricular function with multidetector-row computed tomography versus magnetic resonance imaging
    Fischbach, Roman
    Juergens, Kai Uwe
    Ozgun, Murat
    Maintz, David
    Grude, Matthias
    Seifarth, Harald
    Heindel, Walter
    Wichter, Thomas
    EUROPEAN RADIOLOGY, 2007, 17 (04) : 1009 - 1017
  • [30] Assessment of isolated right ventricular myocardial infarction by magnetic resonance imaging
    Ibrahim, T
    Schwaiger, M
    Schömig, A
    CIRCULATION, 2006, 113 (06) : E78 - E79