Assessment of right ventricular function by 16-detector-row CT: comparison with magnetic resonance imaging

被引:88
|
作者
Koch, K [1 ]
Oellig, F
Oberholzer, K
Bender, P
Kunz, P
Mildenberger, P
Hake, U
Kreitner, KF
Thelen, M
机构
[1] Univ Mainz, Dept Radiol, D-55131 Mainz, Germany
[2] Univ Mainz, Dept Cardiothorac & Vasc Surg, D-55131 Mainz, Germany
关键词
heart; CT; multidetector-row; function; ventricles; MRI;
D O I
10.1007/s00330-004-2543-6
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this study was to determine right ventricular (RV) function from 16-detector-row CT by using two different software tools in comparison with MRI. Nineteen patients underwent cardiac CT. (1) With semiautomated contour detection software end-diastolic and end-systolic RV volumes were determined from short-axis CT reformations (MPR) created at every 10% of the RR-interval. (2) End-systolic and end-diastolic axial images were transformed to 3D to determine the volumes by using a threshold-supported reconstruction algorithm. Steady-state free-precession cine-MRI of the heart was done in short-axis orientation. RV function could not be analyzed in one patient because of sternal wire artifacts in MRI. Mean end-diastolic (155.4 +/- 54.6 ml) and end-systolic (79.1 +/- 37.0 ml) RV volumes determined with MPR correlated well with MRI [151.9 +/- 53.7 ml (r=0.98) and 75.0 +/- 36.0 ml (r=0.96), respectively (P<0.001)]. RV stroke volume (76.2 +/- 20.2 ml for MPR-CT, 76.9 +/- 20.7 ml for MRI, r=0.93) showed a good correlation and RV ejection fraction (50.8 +/- 8.4% for MPR-CT, 51.9 +/- 7.4% for MRI,)-=0.74) only a moderate one. Threshold supported 3D reconstructions revealed insufficient correlations with MRI (r=0.31-0.59). MPR-based semiautomated analysis of cardiac 16 detector-row CT allows for RV functional analysis. The results correlate well with MRI findings. Threshold value-supported 3D reconstructions did not show satisfying results because of inhomogenelties of RV contrast enhancement.
引用
收藏
页码:312 / 318
页数:7
相关论文
共 50 条
  • [11] COMPARISON OF ECHOCARDIOGRAPHIC METHODS WITH MAGNETIC-RESONANCE-IMAGING FOR ASSESSMENT OF RIGHT-VENTRICULAR FUNCTION IN CHILDREN
    HELBING, WA
    BOSCH, HG
    MALIEPAARD, C
    REBERGEN, SA
    VANDERGEEST, RJ
    HANSEN, B
    OTTENKAMP, J
    REIBER, JHC
    DEROOS, A
    AMERICAN JOURNAL OF CARDIOLOGY, 1995, 76 (08): : 589 - 594
  • [12] Comparison of electron beam computed tomography with magnetic resonance Imaging in assessment of right ventricular volumes and function
    Elgeti, T
    Lembcke, A
    Enzweiler, CNH
    Breitwieser, C
    Hamm, B
    Kivelitz, DE
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2004, 28 (05) : 679 - 685
  • [13] Assessment of systemic right ventricular function: A comparison of equilibrium radionuclide ventriculography with magnetic resonance imaging.
    Hornung, T
    Anagnostopoulos, C
    Bardwaj, P
    Kilner, P
    Davlouros, P
    Pennell, DJ
    Underwood, R
    Gatzoulis, M
    CIRCULATION, 2001, 104 (17) : 680 - 680
  • [14] Right ventricular function in idiopathic right ventricular tachycardia evaluated by Doppler myocardial imaging: Comparison with magnetic resonance Imaging
    Almeida, AG
    David, C
    Oliveira, EI
    Sargento, LM
    Sousa, JR
    Rodrigues, S
    Ribeiro, M
    Vagueiro, MC
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 41 (06) : 416A - 416A
  • [15] Assessment of left ventricular myocardial function using 16-slice multidetector-row computed tomography: comparison with magnetic resonance imaging and echocardiography
    Martin Heuschmid
    Julia K. Rothfuss
    Stephen Schroeder
    Michael Fenchel
    Norbert Stauder
    Christof Burgstahler
    Andreas Franow
    Ronald S. Kuzo
    Axel Kuettner
    Stephan Miller
    Claus D. Claussen
    Andreas F. Kopp
    European Radiology, 2006, 16 : 551 - 559
  • [16] A comparison of virtual colonoscopy with fiberoptic colonoscopy by using 16-detector-row computed tomography
    Koplay, Mustafa
    Oenbas, Oemer
    Yilmaz, Oemer
    Alper, Fatih
    Aydinli, Buelent
    Okur, Adnan
    TURKIYE KLINIKLERI TIP BILIMLERI DERGISI, 2007, 27 (03): : 357 - 366
  • [17] Assessment of left ventricular myocardial function using 16-slice multidetector-row computed tomography: comparison with magnetic resonance imaging and echocardiography
    Heuschmid, M
    Rothfuss, JK
    Schroeder, S
    Fenchel, M
    Stauder, N
    Burgstahler, C
    Franow, A
    Kuzo, RS
    Kuettner, A
    Miller, S
    Claussen, CD
    Kopp, AF
    EUROPEAN RADIOLOGY, 2006, 16 (03) : 551 - 559
  • [18] Assessment of coronary stents using 40-detector row CT: Comparison with 16-detector row CT in vitro
    Suzuki, Shigeru
    Furui, Shigeru
    Kuwahara, Sadatoshi
    Vembar, Mani
    Kaminaga, Tatsuro
    Takei, Ryoji
    Isshiki, Takaaki
    Kozuma, Ken
    Aizawa, Tadanori
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2007, 31 (06) : 910 - 916
  • [19] Electrocardiography-synchronized multi-detector row CT of right ventricular function
    Song, Ze-Zhou
    RADIOLOGY, 2008, 246 (03) : 986 - 987
  • [20] Acute myocardial infarction:: Assessment of left ventricular function with 16-detector row spiral CT versus MR imaging -: Study in pigs
    Mahnken, AH
    Katoh, M
    Bruners, P
    Spuentrup, E
    Wildberger, JE
    Günther, RW
    Buecker, A
    RADIOLOGY, 2005, 236 (01) : 112 - 117