Estimated radiation dose according to the craniocaudal angle in cerebral digital subtraction angiography: Patient and phantom study

被引:2
|
作者
Song, Yunsun [1 ]
Kim, Youngeun [2 ]
Han, Seongsik [2 ]
Kim, Tae Il [2 ]
Choi, Joon Ho [2 ]
Maeng, Jun Young [2 ]
Choi, Youngrak [3 ]
Lee, Deok Hee [1 ]
机构
[1] Univ Ulsan, Coll Med, Man Med Ctr, Dept Radiol,Res Inst Radiol, 88,Olymp Ro 43 Gil, Seoul 05505, South Korea
[2] Univ Ulsan, Asan Med Ctr, Coll Med, Dept Radiol Technol, Seoul, South Korea
[3] Siemens Healthineers Ltd, Seoul, South Korea
关键词
Radiation dose; Cerebral angiogram; Digital subtraction angiography; Tube angulation; IMAGE QUALITY; REDUCTION;
D O I
10.1016/j.neurad.2019.07.003
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background and purpose. - Routine use of cranial angulation with 15-20 degrees, craniocaudal angled (CC) view, for cerebral digital subtraction angiography (DSA) helps minimize bone subtraction artifacts with less overlapping of the vessels, however, it may increase the radiation dose. We designed the phantom and patient studies to determine the effect of the angulation to the radiation dose and the feasibility of true posteroanterior angled (PA) view, in cerebral DSA. Materials and methods. - In the phantom study, frontal DSA was simulated with variable angulations. In the patient study with thirty-one subjects, one internal carotid arteriogram was obtained with the CC view and the other, PA view in every patient. The dose-area product (DAP) and reference air-kerma (AK) were measured and compared between the angles. A qualitative analysis was performed to assess the diagnostic performance of the DSA over the angles. Results. - The phantom study confirmed that the greater craniocaudal angles caused higher radiation exposure. Especially, the radiation dose (AK) of the CC view was 5.4% higher than that of the PA view. In the patient study, the radiation dose of the PA view was significantly lower compared to the CC view (1.44 vs. 1.63 mGy, AK). In 4 patients, the dose particularly jumped when applying the CC view as the copper filter was automatically removed. The diagnostic ability of the DSA with the PA view tended to be higher without significance. Conclusions. - In a daily routine cerebral angiography, a simple modification of the angle may help to minimize the radiation dose. (C) 2019 Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:345 / 350
页数:6
相关论文
共 50 条
  • [41] Automatically Predicting Modified Treatment in Cerebral Ischemia Scores From Patient Digital Subtraction Angiography Using Deep Learning
    Lall, Ayush
    Scalzo, Fabien
    Ullman, Henrik
    Liebeskind, David S.
    Chien, Aichi
    STROKE, 2021, 52
  • [42] COMPARISON OF RADIATION DOSE TO PATIENT AND STAFF FOR TWO INTERVENTIONAL CARDIOLOGY UNITS: A PHANTOM STUDY
    Mesbahi, Asghar
    Mehnati, Parinaz
    Keshtkar, Ahmad
    Aslanabadi, Naser
    RADIATION PROTECTION DOSIMETRY, 2008, 131 (03) : 399 - 403
  • [43] Effect of X-ray Tube Parameters and Iodine Concentration on Image Quality and Radiation Dose in Cerebral Pediatric and Adult CT Angiography A Phantom Study
    Papadakis, Antonios E.
    Perisinakis, Kostas
    Raissaki, Maria
    Damilakis, John
    INVESTIGATIVE RADIOLOGY, 2013, 48 (04) : 192 - 199
  • [44] Radiation Dose Incurred in the Exclusion of Vascular Filling in Transforaminal Epidural Steroid Injections: Fluoroscopy, Digital Subtraction Angiography, and CT/Fluoroscopy
    Maus, Timothy
    Schueler, Beth A.
    Leng, Shuai
    Magnuson, Dayne
    Magnuson, Dixon J.
    Diehn, Felix E.
    PAIN MEDICINE, 2014, 15 (08) : 1328 - 1333
  • [45] Effect of kVp on image quality and accuracy in coronary CT angiography according to patient body size: a phantom study
    Lee, Sang Min
    Lee, Whal
    Chung, Jin Wook
    Park, Eun-Ah
    Park, Jae Hyung
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2013, 29 : 83 - 91
  • [46] Effect of kVp on image quality and accuracy in coronary CT angiography according to patient body size: a phantom study
    Sang Min Lee
    Whal Lee
    Jin Wook Chung
    Eun-Ah Park
    Jae Hyung Park
    The International Journal of Cardiovascular Imaging, 2013, 29 : 83 - 91
  • [47] Subjective and objective evaluation of image quality in biplane cerebral digital subtraction angiography following significant acquisition dose reduction in a clinical setting
    Honarmand, Amir R.
    Shaibani, Ali
    Pashaee, Tamila
    Syed, Furqan H.
    Hurley, Michael C.
    Sammet, Christina L.
    Potts, Matthew B.
    Jahromi, Babak S.
    Ansari, Sameer A.
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2017, 9 (03) : 297 - 301
  • [48] Evaluation of Dose Distribution According to Patient Setup Errors in Pediatric Head CT Examination: A Phantom Study
    Gotanda, Rumi
    Takeda, Yoshihiro
    Gotanda, Tatsuhiro
    Ota, Kosuke
    Akagawa, Takuya
    Tabuchi, Akihiko
    Kuwano, Tadao
    Yatake, Hidetoshi
    Yabunaka, Koichi
    Sato, Hitoshi
    Katsuda, Toshizo
    6TH EUROPEAN CONFERENCE OF THE INTERNATIONAL FEDERATION FOR MEDICAL AND BIOLOGICAL ENGINEERING, 2015, 45 : 224 - 227
  • [49] Dual-Energy CT Angiography in the Evaluation of Intracranial Aneurysms: Image Quality, Radiation Dose, and Comparison With 3D Rotational Digital Subtraction Angiography
    Zhang, Long-Jiang
    Wu, Sheng-Yong
    Niu, Jing-Bo
    Zhang, Zhuo-Li
    Wang, Henry Z.
    Zhao, Yan-E
    Chai, Xue
    Zhou, Chang-Sheng
    Lu, Guang-Ming
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (01) : 23 - 30
  • [50] A Patient-Specific 4D Digital Phantom for Dynamic Dose Estimation of External Ionizing Radiation
    Deng, J.
    MEDICAL PHYSICS, 2012, 39 (06) : 3693 - 3693