Estimated radiation dose according to the craniocaudal angle in cerebral digital subtraction angiography: Patient and phantom study

被引:2
|
作者
Song, Yunsun [1 ]
Kim, Youngeun [2 ]
Han, Seongsik [2 ]
Kim, Tae Il [2 ]
Choi, Joon Ho [2 ]
Maeng, Jun Young [2 ]
Choi, Youngrak [3 ]
Lee, Deok Hee [1 ]
机构
[1] Univ Ulsan, Coll Med, Man Med Ctr, Dept Radiol,Res Inst Radiol, 88,Olymp Ro 43 Gil, Seoul 05505, South Korea
[2] Univ Ulsan, Asan Med Ctr, Coll Med, Dept Radiol Technol, Seoul, South Korea
[3] Siemens Healthineers Ltd, Seoul, South Korea
关键词
Radiation dose; Cerebral angiogram; Digital subtraction angiography; Tube angulation; IMAGE QUALITY; REDUCTION;
D O I
10.1016/j.neurad.2019.07.003
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background and purpose. - Routine use of cranial angulation with 15-20 degrees, craniocaudal angled (CC) view, for cerebral digital subtraction angiography (DSA) helps minimize bone subtraction artifacts with less overlapping of the vessels, however, it may increase the radiation dose. We designed the phantom and patient studies to determine the effect of the angulation to the radiation dose and the feasibility of true posteroanterior angled (PA) view, in cerebral DSA. Materials and methods. - In the phantom study, frontal DSA was simulated with variable angulations. In the patient study with thirty-one subjects, one internal carotid arteriogram was obtained with the CC view and the other, PA view in every patient. The dose-area product (DAP) and reference air-kerma (AK) were measured and compared between the angles. A qualitative analysis was performed to assess the diagnostic performance of the DSA over the angles. Results. - The phantom study confirmed that the greater craniocaudal angles caused higher radiation exposure. Especially, the radiation dose (AK) of the CC view was 5.4% higher than that of the PA view. In the patient study, the radiation dose of the PA view was significantly lower compared to the CC view (1.44 vs. 1.63 mGy, AK). In 4 patients, the dose particularly jumped when applying the CC view as the copper filter was automatically removed. The diagnostic ability of the DSA with the PA view tended to be higher without significance. Conclusions. - In a daily routine cerebral angiography, a simple modification of the angle may help to minimize the radiation dose. (C) 2019 Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:345 / 350
页数:6
相关论文
共 50 条
  • [21] Options for radiation dose optimisation in pelvic digital radiography: A phantom study
    Manning-Stanley, Anthony S.
    Ward, Anthony J.
    England, Andrew
    RADIOGRAPHY, 2012, 18 (04) : 256 - 263
  • [22] A phantom study of image quality versus radiation dose for digital radiography
    Tung, C. J.
    Tsai, H. Y.
    Shi, M. Y.
    Huang, T. T.
    Yang, C. H.
    Chen, I. J.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 580 (01): : 602 - 605
  • [23] Comparing Radiation Dose of Cerebral Angiography Using Conventional and High kV Techniques: A Retrospective Study on Intracranial Aneurysm Patients and a Phantom Study
    Kirisattayakul, Woranan
    Pattum, Panuwat
    Munkong, Waranon
    Prabsattroo, Thawatchai
    Khottapat, Chonnatcha
    Chomkhunthod, Tanyalak
    Pungkun, Vithit
    TOMOGRAPHY, 2023, 9 (02) : 621 - 632
  • [24] Optimizing the Angiography Protocol to Reduce Radiation Dose in Uterine Artery Embolization: The Impact of Digital Subtraction Angiographies on Radiation Exposure
    Cina, Alessandro
    Steri, Lorenzo
    Barbieri, Pierluigi
    Contegiacomo, Andrea
    Amodeo, Enrico Maria
    Di Stasi, Carmine
    Morasca, Andrea
    Romualdi, Daniela
    Ciccarone, Francesca
    Manfredi, Riccardo
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2022, 45 (02) : 249 - 254
  • [25] Optimizing the Angiography Protocol to Reduce Radiation Dose in Uterine Artery Embolization: The Impact of Digital Subtraction Angiographies on Radiation Exposure
    Alessandro Cina
    Lorenzo Steri
    Pierluigi Barbieri
    Andrea Contegiacomo
    Enrico Maria Amodeo
    Carmine Di Stasi
    Andrea Morasca
    Daniela Romualdi
    Francesca Ciccarone
    Riccardo Manfredi
    CardioVascular and Interventional Radiology, 2022, 45 : 249 - 254
  • [26] Ultra low radiation dose digital subtraction angiography (DSA) imaging using low rank constraint
    Niu, Kai
    Li, Yinsheng
    Schafer, Sebastian
    Royalty, Kevin
    Wu, Yijing
    Strother, Charles
    Chen, Guang-Hong
    MEDICAL IMAGING 2015: PHYSICS OF MEDICAL IMAGING, 2015, 9412
  • [27] RADIATION EXPOSURE WITH DIGITAL SUBTRACTION ANGIOGRAPHY IN PEDIATRIC-PATIENTS - AN EXPERIMENTAL-STUDY
    ALZEN, G
    BOECK, EG
    VORWERK, D
    THELEN, M
    GUENTHER, R
    PEDIATRIC RADIOLOGY, 1986, 16 (04) : 342 - 342
  • [28] Radiation doses in cerebral perfusion computed tomography: patient and phantom study
    Arandjic, D.
    Bonutti, F.
    Biasizzo, E.
    Ciraj-Bjelac, O.
    Floreani, M.
    Giustizieri, M.
    Iaiza, F.
    Inkoom, S.
    Tommasini, G.
    Padovani, R.
    RADIATION PROTECTION DOSIMETRY, 2013, 154 (04) : 459 - 464
  • [29] Fetal radiation dose from CT pulmonary angiography in late pregnancy: a phantom study
    Doshi, S. K.
    Negus, I. S.
    Oduko, J. M.
    BRITISH JOURNAL OF RADIOLOGY, 2008, 81 (968): : 653 - 658
  • [30] Reference Values of Cerebral Artery Diameters of the Anterior Circulation by Digital Subtraction Angiography: A Retrospective Study
    Halama, Dirk
    Merkel, Helena
    Werdehausen, Robert
    Gaber, Khaled
    Schob, Stefan
    Quaschling, Ulf
    Ziganshyna, Svitlana
    Hoffmann, Karl-Titus
    Lindner, Dirk
    Richter, Cindy
    DIAGNOSTICS, 2022, 12 (10)