Modeling and Estimation of Tip Contact Force for Steerable Ablation Catheters

被引:67
|
作者
Khoshnam, Mahta [1 ,2 ]
Skanes, Allan C. [3 ,4 ]
Patel, Rajni V. [1 ,2 ,5 ]
机构
[1] Univ Western Ontario, Dept Elect & Comp Engn, London, ON N6A 5A5, Canada
[2] Canadian Surg Technol & Adv Robot, London, ON N6A 5A5, Canada
[3] Univ Western Ontario, Schulich Sch Med & Dent, London, ON N6A 5A5, Canada
[4] Univ Western Ontario Hosp, London Hlth Sci Ctr, Electrophysiol Lab, London, ON N6A 5A5, Canada
[5] Univ Western Ontario, Dept Surg, London, ON N6A 5A5, Canada
基金
加拿大创新基金会; 加拿大自然科学与工程研究理事会;
关键词
Ablation catheter; contact force; kinematics; modeling;
D O I
10.1109/TBME.2015.2389615
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective: The efficacy of catheter-based cardiac ablation procedures can be significantly improved if real-time information is available concerning contact forces between the catheter tip and cardiac tissue. However, the widely used ablation catheters are not equipped for force sensing. This paper proposes a technique for estimating the contact forces without direct force measurements by studying the changes in the shape of the deflectable distal section of a conventional 7-Fr catheter (henceforth called the "deflectable distal shaft," the "deflectable shaft," or the "shaft" of the catheter) in different loading situations. Method: First, the shaft curvature when the tip is moving in free space is studied and based on that, a kinematic model for the deflectable shaft in free space is proposed. In the next step, the shaft shape is analyzed in the case where the tip is in contact with the environment, and it is shown that the curvature of the deflectable shaft provides useful information about the loading status of the catheter and can be used to define an index for determining the range of contact forces exerted by the ablation tip. Results: Experiments with two different steerable ablation catheters show that the defined index can detect the range of applied contact forces correctly in more than 80% of the cases. Based on the proposed technique, a framework for obtaining contact force information by using the shaft curvature at a limited number of points along the deflectable shaft is constructed. Conclusion: The proposed kinematic model and the force estimation technique can be implemented together to describe the catheter's behavior before contact, detect tip/tissue contact, and determine the range of contact forces. Significance: This study proves that the flexibility of the catheter's distal shaft provides a means of estimating the force exerted on tissue by the ablation tip.
引用
收藏
页码:1404 / 1415
页数:12
相关论文
共 50 条
  • [41] Association between the use of contact force-sensing catheters and cardiac tamponade in atrial fibrillation ablation
    Nian Liu
    Qianqian Zhao
    Linling Li
    Mengxia Zhang
    Jiao Huang
    Sheng Wei
    Songnan Wen
    Yanfei Ruan
    Xueyuan Guo
    Songnan Li
    Chengxi Jiang
    Ribo Tang
    Caihua Sang
    Deyong Long
    Ronghui Yu
    Rong Bai
    Xin Du
    Jianzeng Dong
    Changsheng Ma
    Journal of Interventional Cardiac Electrophysiology, 2019, 55 : 137 - 143
  • [42] Porous tip contact force-sensing catheters for pulmonary vein isolation: performance in a clinical routine setting
    Plenge, Tobias
    van den Bruck, Jan-Hendrik
    Lueker, Jakob
    Sultan, Arian
    Steven, Daniel
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2020, 57 (02) : 251 - 259
  • [43] The Evaluation of Steerable Ultrasonic Catheters for Minimally Invasive MRI-Guided Cardiac Ablation
    Carias, Mathew
    Hynynen, Kullervo
    MAGNETIC RESONANCE IN MEDICINE, 2014, 72 (02) : 591 - 598
  • [44] Reproducibility of Paroxysmal Atrial Fibrillation Ablation Clinical Outcomes Using Composite Ablation Index With Different Contact Force-Sensing Catheters
    Di Biase, Luigi
    Tabereaux, Paul
    Liu, Christopher F.
    Vasaiwala, Smit
    Chugh, Aman
    Saliba, Walid I.
    CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2022, 15 (12):
  • [45] Estimation Methods of Flexible Tip-Steerable Needles: A Comparative Study
    Zou, Y. J.
    Zhao, X. G.
    Han, J. D.
    2014 11TH WORLD CONGRESS ON INTELLIGENT CONTROL AND AUTOMATION (WCICA), 2014, : 5051 - 5056
  • [46] Impact of pulmonary veins anatomy on the outcomes of radiofrequency ablation for paroxysmal atrial fibrillation in the era of contact force-sensing ablation catheters
    Karim Benali
    Van Duc Lai
    Nefissa Hammache
    Isabelle Magnin-Poull
    Christian de Chillou
    Jean-Marc Sellal
    Journal of Interventional Cardiac Electrophysiology, 2023, 66 : 931 - 940
  • [47] Impact of pulmonary veins anatomy on the outcomes of radiofrequency ablation for paroxysmal atrial fibrillation in the era of contact force-sensing ablation catheters
    Benali, Karim
    Lai, Van Duc
    Hammache, Nefissa
    Magnin-Poull, Isabelle
    de Chillou, Christian
    Sellal, Jean-Marc
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2023, 66 (04) : 931 - 940
  • [48] A Contact-Aided Asymmetric Steerable Catheter for Atrial Fibrillation Ablation
    Gao, Anzhu
    Liu, Hao
    Zou, Yun
    Wang, Zhidong
    Liang, Ming
    Wang, Zulu
    IEEE ROBOTICS AND AUTOMATION LETTERS, 2017, 2 (03): : 1525 - 1531
  • [49] Excessive contact force can overcome irrigated tip catheter benefits during atrial fibrillation ablation
    Bunch, T. Jared
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2018, 29 (02) : 236 - 238
  • [50] Atrial fibrillation ablation using very short duration 50 W ablations and contact force sensing catheters
    Winkle, Roger A.
    Moskovitz, Ryan
    Mead, R. Hardwin
    Engel, Gregory
    Kong, Melissa
    Fleming, William
    Salcedo, Jonathan
    Patrawala, Rob
    Tranter, John
    Shai, Isacc
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2018, 29 (04) : 672 - 673