Modeling and Estimation of Tip Contact Force for Steerable Ablation Catheters

被引:67
|
作者
Khoshnam, Mahta [1 ,2 ]
Skanes, Allan C. [3 ,4 ]
Patel, Rajni V. [1 ,2 ,5 ]
机构
[1] Univ Western Ontario, Dept Elect & Comp Engn, London, ON N6A 5A5, Canada
[2] Canadian Surg Technol & Adv Robot, London, ON N6A 5A5, Canada
[3] Univ Western Ontario, Schulich Sch Med & Dent, London, ON N6A 5A5, Canada
[4] Univ Western Ontario Hosp, London Hlth Sci Ctr, Electrophysiol Lab, London, ON N6A 5A5, Canada
[5] Univ Western Ontario, Dept Surg, London, ON N6A 5A5, Canada
基金
加拿大创新基金会; 加拿大自然科学与工程研究理事会;
关键词
Ablation catheter; contact force; kinematics; modeling;
D O I
10.1109/TBME.2015.2389615
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective: The efficacy of catheter-based cardiac ablation procedures can be significantly improved if real-time information is available concerning contact forces between the catheter tip and cardiac tissue. However, the widely used ablation catheters are not equipped for force sensing. This paper proposes a technique for estimating the contact forces without direct force measurements by studying the changes in the shape of the deflectable distal section of a conventional 7-Fr catheter (henceforth called the "deflectable distal shaft," the "deflectable shaft," or the "shaft" of the catheter) in different loading situations. Method: First, the shaft curvature when the tip is moving in free space is studied and based on that, a kinematic model for the deflectable shaft in free space is proposed. In the next step, the shaft shape is analyzed in the case where the tip is in contact with the environment, and it is shown that the curvature of the deflectable shaft provides useful information about the loading status of the catheter and can be used to define an index for determining the range of contact forces exerted by the ablation tip. Results: Experiments with two different steerable ablation catheters show that the defined index can detect the range of applied contact forces correctly in more than 80% of the cases. Based on the proposed technique, a framework for obtaining contact force information by using the shaft curvature at a limited number of points along the deflectable shaft is constructed. Conclusion: The proposed kinematic model and the force estimation technique can be implemented together to describe the catheter's behavior before contact, detect tip/tissue contact, and determine the range of contact forces. Significance: This study proves that the flexibility of the catheter's distal shaft provides a means of estimating the force exerted on tissue by the ablation tip.
引用
收藏
页码:1404 / 1415
页数:12
相关论文
共 50 条
  • [31] Contact force-sensing catheters
    Hoffmayer, Kurt S.
    Gerstenfeld, Edward P.
    CURRENT OPINION IN CARDIOLOGY, 2015, 30 (01) : 74 - 80
  • [32] Clinical experience with contact-force and flexible-tip ablation catheter designs
    N. Deubner
    H. Greiss
    E. Akkaya
    A. Berkowitsch
    S. Zaltsberg
    C. W. Hamm
    M. Kuniss
    T. Neumann
    Journal of Interventional Cardiac Electrophysiology, 2016, 47 : 75 - 82
  • [33] Clinical experience with contact-force and flexible-tip ablation catheter designs
    Deubner, N.
    Greiss, H.
    Akkaya, E.
    Berkowitsch, A.
    Zaltsberg, S.
    Hamm, C. W.
    Kuniss, M.
    Neumann, T.
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2016, 47 (01) : 75 - 82
  • [34] A Novel Methodology for Comprehensive Modeling of the Kinetic Behavior of Steerable Catheters
    Hu, Xiaohua
    Cao, Lin
    Luo, Yigang
    Chen, Ang
    Zhang, Edwin
    Zhang, W. J.
    IEEE-ASME TRANSACTIONS ON MECHATRONICS, 2019, 24 (04) : 1785 - 1797
  • [35] Porous tip contact force–sensing catheters for pulmonary vein isolation: performance in a clinical routine setting
    Tobias Plenge
    Jan-Hendrik van den Bruck
    Jakob Lüker
    Arian Sultan
    Daniel Steven
    Journal of Interventional Cardiac Electrophysiology, 2020, 57 : 251 - 259
  • [36] INTRACARDIAC ECHOCARDIOGRAPHY (ICE) BASED VALIDATION OF CONTACT FORCE SENSING TO GUIDE IRRIGATED TIP ABLATION
    Swale, M.
    Gard, J.
    Johnson, S. B.
    Parker, K.
    Packer, D.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2011, 22 : S112 - S113
  • [37] Association between the use of contact force-sensing catheters and cardiac tamponade in atrial fibrillation ablation
    Liu, Nian
    Zhao, Qianqian
    Li, Linling
    Zhang, Mengxia
    Huang, Jiao
    Wei, Sheng
    Wen, Songnan
    Ruan, Yanfei
    Guo, Xueyuan
    Li, Songnan
    Jiang, Chengxi
    Tang, Ribo
    Sang, Caihua
    Long, Deyong
    Yu, Ronghui
    Bai, Rong
    Du, Xin
    Dong, Jianzeng
    Ma, Changsheng
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2019, 55 (02) : 137 - 143
  • [38] Human Body Modeling for Ground Contact Force Estimation of RoboWalk
    Absalan, Farshid
    Moosavian, S. Ali A.
    2019 7TH INTERNATIONAL CONFERENCE ON ROBOTICS AND MECHATRONICS (ICROM 2019), 2019, : 86 - 92
  • [39] Accurate Estimation of Tip Force on Tendon-driven Catheters using Inverse Cosserat Rod Model
    Hooshiar, Amir
    Sayadi, Amir
    Jolaei, Mohammad
    Dargahi, Javad
    PROCEEDINGS OF THE 2020 INTERNATIONAL CONFERENCE ON BIOMEDICAL INNOVATIONS AND APPLICATIONS (BIA 2020), 2020, : 37 - 40
  • [40] Irrigated tip catheters: experimental study on the ablation of the cavotricuspid isthmus
    Rebollo, JG
    Madrid, A
    del Rey, JM
    Alvarez, T
    Correa, C
    Chercoles, AI
    Lobelo, R
    Socas, A
    Pena, G
    Moro, C
    EUROPEAN HEART JOURNAL, 2000, 21 : 445 - 445