Modeling and Estimation of Tip Contact Force for Steerable Ablation Catheters

被引:67
|
作者
Khoshnam, Mahta [1 ,2 ]
Skanes, Allan C. [3 ,4 ]
Patel, Rajni V. [1 ,2 ,5 ]
机构
[1] Univ Western Ontario, Dept Elect & Comp Engn, London, ON N6A 5A5, Canada
[2] Canadian Surg Technol & Adv Robot, London, ON N6A 5A5, Canada
[3] Univ Western Ontario, Schulich Sch Med & Dent, London, ON N6A 5A5, Canada
[4] Univ Western Ontario Hosp, London Hlth Sci Ctr, Electrophysiol Lab, London, ON N6A 5A5, Canada
[5] Univ Western Ontario, Dept Surg, London, ON N6A 5A5, Canada
基金
加拿大创新基金会; 加拿大自然科学与工程研究理事会;
关键词
Ablation catheter; contact force; kinematics; modeling;
D O I
10.1109/TBME.2015.2389615
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective: The efficacy of catheter-based cardiac ablation procedures can be significantly improved if real-time information is available concerning contact forces between the catheter tip and cardiac tissue. However, the widely used ablation catheters are not equipped for force sensing. This paper proposes a technique for estimating the contact forces without direct force measurements by studying the changes in the shape of the deflectable distal section of a conventional 7-Fr catheter (henceforth called the "deflectable distal shaft," the "deflectable shaft," or the "shaft" of the catheter) in different loading situations. Method: First, the shaft curvature when the tip is moving in free space is studied and based on that, a kinematic model for the deflectable shaft in free space is proposed. In the next step, the shaft shape is analyzed in the case where the tip is in contact with the environment, and it is shown that the curvature of the deflectable shaft provides useful information about the loading status of the catheter and can be used to define an index for determining the range of contact forces exerted by the ablation tip. Results: Experiments with two different steerable ablation catheters show that the defined index can detect the range of applied contact forces correctly in more than 80% of the cases. Based on the proposed technique, a framework for obtaining contact force information by using the shaft curvature at a limited number of points along the deflectable shaft is constructed. Conclusion: The proposed kinematic model and the force estimation technique can be implemented together to describe the catheter's behavior before contact, detect tip/tissue contact, and determine the range of contact forces. Significance: This study proves that the flexibility of the catheter's distal shaft provides a means of estimating the force exerted on tissue by the ablation tip.
引用
收藏
页码:1404 / 1415
页数:12
相关论文
共 50 条
  • [1] Estimating Contact Force for Steerable Ablation Catheters based on Shape Analysis
    Khoshnam, Mahta
    Patel, Rajni V.
    2014 IEEE/RSJ INTERNATIONAL CONFERENCE ON INTELLIGENT ROBOTS AND SYSTEMS (IROS 2014), 2014, : 3509 - 3514
  • [2] Effects of Blood Flow on the Tip Contact Force of Cardiac Ablation Catheters
    Khoshbakht, Reza
    Kheiri, Mojtaba
    Dargahi, Javad
    Hooshiar, Amir
    2022 IEEE INTERNATIONAL SYMPOSIUM ON ROBOTIC AND SENSORS ENVIRONMENTS (ROSE), 2022,
  • [3] Image-based Contact Detection and Static Force Estimation on Steerable RFA Catheters
    Yaftian, Pegah
    Bandari, Naghmeh
    Hooshiar, Amir
    Dargahi, Javad
    PROCEEDINGS OF THE 2020 INTERNATIONAL CONFERENCE ON BIOMEDICAL INNOVATIONS AND APPLICATIONS (BIA 2020), 2020, : 57 - 60
  • [4] Machine-Learning-Based Multi-Modal Force Estimation for Steerable Ablation Catheters
    Arefinia, Elaheh
    Jagadeesan, Jayender
    Patel, Rajni V.
    IEEE TRANSACTIONS ON MEDICAL ROBOTICS AND BIONICS, 2024, 6 (03): : 1004 - 1016
  • [5] Black-Box Modeling and Control of Steerable Ablation Catheters
    Khoshnam, Mahta
    Yadmellat, Peyman
    Patel, Rajni V.
    2016 IEEE INTERNATIONAL CONFERENCE ON ADVANCED INTELLIGENT MECHATRONICS (AIM), 2016, : 1192 - 1197
  • [6] Tendon-Sheath Analysis for Modeling and Control of Steerable Ablation Catheters
    Khoshnam, Mahta
    Patel, Rajni V.
    2016 IEEE INTERNATIONAL CONFERENCE ON ADVANCED INTELLIGENT MECHATRONICS (AIM), 2016, : 1585 - 1590
  • [7] Comparison of Steerable Sheaths for Radiofrequency Ablation: Contact Force & Torque Transfer
    Wasserlauf, Jeremiah
    Sukumar, Aravin
    Al-Dujaili, Saja
    Knight, Bradley
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2024, 35 (06) : 1306 - 1307
  • [8] Optical contact force monitoring sensor for cardiac ablation catheters
    Kim, Jang Ah
    Park, Kihong
    Kim, Changmin
    Kulkarni, Atul
    Kim, Taesung
    OPTIK, 2016, 127 (24): : 11823 - 11827
  • [9] Temperature-Insensitive Fiber-Optic Contact Force Sensor for Steerable Catheters
    Xu, Li
    Miller, Matthew I.
    Ge, Jia
    Nilsson, Kent R.
    Tse, Zion Tsz Ho
    Fok, Mable P.
    IEEE SENSORS JOURNAL, 2016, 16 (12) : 4771 - 4775
  • [10] Accessory pathway ablation in the era of electroanatomic mapping systems and contact force ablation catheters
    Marques, C. Catarina
    Moreira, H. S.
    Cabrita, A.
    Calvao, J.
    Costa, C. M.
    Amador, A. F.
    Oliveira, C.
    Santos, L. D.
    Pinho, A. I.
    Palma, P. M.
    Rocha, M.
    Lebreiro, A.
    Adao, L.
    Macedo, F.
    EUROPEAN JOURNAL OF HEART FAILURE, 2023, 25 : 392 - 392