A simulation of the effects of set-up error and changes in breast volume on conventional and intensity-modulated treatments in breast radiotherapy

被引:16
|
作者
Hector, C
Webb, S
Evans, PM
机构
[1] Inst Canc Res, Joint Dept Phys, Sutton SM2 5PT, Surrey, England
[2] Royal Marsden NHS Trust, Sutton SM2 5PT, Surrey, England
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2001年 / 46卷 / 05期
关键词
D O I
10.1088/0031-9155/46/5/309
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The effect of interfractional patient movement on dosimetry has been investigated for breast radiotherapy. Errors in patient set-up and changes in breast volume were simulated individually to determine how each contributes to the total dosimetric error. Two treatment techniques were investigated: a conventional treatment and an intensity-modulated treatment delivered using compensators. Six patients were investigated and anterior-posterior (AP) and superior-inferior (SI) displacements were simulated by displacing the isocentre in both directions by 2, 5 and 10 mm. A model of the breast was developed from the six patients to simulate changes in breast volume. In this model, the breast was described as a set of semi-ellipses. The volume of the breast was changed by varying the magnitude of the semi-major and semi-minor axes. Anisotropic changes in breast volume were also investigated. The dosimetric error was evaluated for each dose plan by calculating the volume outside the 95-105% dose range resulting from the simulations. A number of parameters describing the size and shape of the breast were also investigated to determine whether a susceptibility of outline sets to interfractional patient movement could be predicted. A parameter describing the increase in the breast volume outside the 95-105% dose range was calculated for AP and SI set-up errors of +/-3 mm and changes in breast volume of 5%. Results revealed that set-up errors were likely to cause larger increases in the volume outside the 95-105% dose range than changes in breast volume for typical set-up errors and changes in breast volume that occur during treatment. The magnitude of the set-up errors and changes in breast volume were observed to be dependent on the shape outline set. Statistically significant linear correlation was observed between the increase in the volume outside the 95-105% dose range and several of the evaluation parameters.
引用
收藏
页码:1451 / 1471
页数:21
相关论文
共 50 条
  • [41] Comorbidities and intensity-modulated radiotherapy with simultaneous integrated boost in elderly breast cancer patients
    Fiorentino, Alba
    Mazzola, Rosario
    Levra, Niccolo Giaj
    Fersino, Sergio
    Ricchetti, Francesco
    Di Paola, Gioacchino
    Gori, Stefania
    Massocco, Alberto
    Alongi, Filippo
    AGING CLINICAL AND EXPERIMENTAL RESEARCH, 2018, 30 (05) : 533 - 538
  • [42] Comment: "Cosmesis in patients with breast neoplasia submitted to the hypofractionated radiotherapy with of intensity-modulated beam"
    de Carvalho, Icaro T.
    REVISTA DA ASSOCIACAO MEDICA BRASILEIRA, 2018, 64 (11): : 1031 - 1031
  • [43] Direct aperture optimization-based intensity-modulated radiotherapy for whole breast irradiation
    Ahunbay, Ergun E.
    Chen, Guang-Pei
    Thatcher, Steven
    Jursinic, Paul A.
    White, Julia
    Albano, Katherine
    Li, X. Allen
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 67 (04): : 1248 - 1258
  • [44] Dose prescription point in forward intensity-modulated radiotherapy of breast and head/neck cancers
    Allaveisi F.
    Amini N.
    Sakineh Pour S.
    Radiological Physics and Technology, 2018, 11 (4) : 382 - 391
  • [45] Early Experience of Tomotherapy-based Intensity-modulated Radiotherapy for Breast Cancer Treatment
    O'Donnell, H.
    Cooke, K.
    Walsh, N.
    Plowman, P. N.
    CLINICAL ONCOLOGY, 2009, 21 (04) : 294 - 301
  • [46] Comorbidities and intensity-modulated radiotherapy with simultaneous integrated boost in elderly breast cancer patients
    Alba Fiorentino
    Rosario Mazzola
    Niccolò Giaj Levra
    Sergio Fersino
    Francesco Ricchetti
    Gioacchino Di Paola
    Stefania Gori
    Alberto Massocco
    Filippo Alongi
    Aging Clinical and Experimental Research, 2018, 30 : 533 - 538
  • [47] CLINICAL EXPERIENCE WITH IMAGE-GUIDED RADIOTHERAPY IN AN ACCELERATED PARTIAL BREAST INTENSITY-MODULATED RADIOTHERAPY PROTOCOL
    Leonard, Charles E.
    Tallhamer, Michael
    Johnson, Tim
    Hunter, Kari
    Howell, Kathryn
    Kercher, Jane
    Widener, Jodi
    Kaske, Terese
    Paul, Devchand
    Sedlacek, Scot
    Carter, Dennis L.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 76 (02): : 528 - 534
  • [48] Dosimetric comparison of field in field intensity-modulated radiotherapy technique with conformal radiotherapy techniques in breast cancer
    Ercan, Tuelay
    Igdem, Sefik
    Alco, Guel
    Zengin, Funda
    Atilla, Selin
    Dincer, Maktav
    Okkan, Sait
    JAPANESE JOURNAL OF RADIOLOGY, 2010, 28 (04) : 283 - 289
  • [49] Using Robust Optimization for Skin Flashing in Intensity-Modulated Radiotherapy for Breast Cancer Treatment
    Liang, X.
    Bradley, J. A.
    Vega, R. Mailhot
    Rutenberg, M.
    Zheng, D.
    Getman, N.
    Norton, K. W.
    Mendenhall, N.
    Li, Z.
    MEDICAL PHYSICS, 2019, 46 (06) : E560 - E560
  • [50] Dosimetric comparison of field in field intensity-modulated radiotherapy technique with conformal radiotherapy techniques in breast cancer
    Tülay Ercan
    Şefik İğdem
    Gül Alço
    Funda Zengin
    Selin Atilla
    Maktav Dinçer
    Sait Okkan
    Japanese Journal of Radiology, 2010, 28 : 283 - 289