A simulation of the effects of set-up error and changes in breast volume on conventional and intensity-modulated treatments in breast radiotherapy

被引:16
|
作者
Hector, C
Webb, S
Evans, PM
机构
[1] Inst Canc Res, Joint Dept Phys, Sutton SM2 5PT, Surrey, England
[2] Royal Marsden NHS Trust, Sutton SM2 5PT, Surrey, England
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2001年 / 46卷 / 05期
关键词
D O I
10.1088/0031-9155/46/5/309
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The effect of interfractional patient movement on dosimetry has been investigated for breast radiotherapy. Errors in patient set-up and changes in breast volume were simulated individually to determine how each contributes to the total dosimetric error. Two treatment techniques were investigated: a conventional treatment and an intensity-modulated treatment delivered using compensators. Six patients were investigated and anterior-posterior (AP) and superior-inferior (SI) displacements were simulated by displacing the isocentre in both directions by 2, 5 and 10 mm. A model of the breast was developed from the six patients to simulate changes in breast volume. In this model, the breast was described as a set of semi-ellipses. The volume of the breast was changed by varying the magnitude of the semi-major and semi-minor axes. Anisotropic changes in breast volume were also investigated. The dosimetric error was evaluated for each dose plan by calculating the volume outside the 95-105% dose range resulting from the simulations. A number of parameters describing the size and shape of the breast were also investigated to determine whether a susceptibility of outline sets to interfractional patient movement could be predicted. A parameter describing the increase in the breast volume outside the 95-105% dose range was calculated for AP and SI set-up errors of +/-3 mm and changes in breast volume of 5%. Results revealed that set-up errors were likely to cause larger increases in the volume outside the 95-105% dose range than changes in breast volume for typical set-up errors and changes in breast volume that occur during treatment. The magnitude of the set-up errors and changes in breast volume were observed to be dependent on the shape outline set. Statistically significant linear correlation was observed between the increase in the volume outside the 95-105% dose range and several of the evaluation parameters.
引用
收藏
页码:1451 / 1471
页数:21
相关论文
共 50 条
  • [21] Intensity-modulated radiotherapy technique for three-field breast treatment
    Chui, CS
    Hong, L
    McCormick, B
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 62 (04): : 1217 - 1223
  • [22] Intensity-modulated radiotherapy of breast cancer using direct aperture optimization
    van Asselen, Bram
    Schwarz, Marco
    van Vliet-Vroegindeweij, Corine
    Lebesque, Joos V.
    Mijnheer, Ben J.
    Damen, Eugene M. F.
    RADIOTHERAPY AND ONCOLOGY, 2006, 79 (02) : 162 - 169
  • [23] Accelerated intensity-modulated radiotherapy to breast in prone position: Dosimetric results
    DeWyngaert, J. Keith
    Jozsef, Gabor
    Mitchell, James
    Rosenstein, Barry
    Formenti, Silvia C.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 68 (04): : 1251 - 1259
  • [24] Intensity-modulated radiotherapy for the adjuvant treatment of breast cancer: a prospective study
    Pasquier, D.
    Le Tinier, F.
    Jouin, A.
    Horn, S.
    Boughzala, R.
    Escande, A.
    Tresch, E.
    Crop, F.
    Mirabel, X.
    Lartigau, E.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S381 - S381
  • [25] Accelerated Partial Breast Intensity-Modulated Radiotherapy in Women Who Have Prior Breast Augmentation
    Leonard, Charles E.
    Johnson, Tim
    Tallhamer, Michael
    Howell, Kathryn
    Kercher, Jane
    Kaske, Terese
    Barke, Lora
    Sedlacek, Scot
    Hobart, Tracy
    Carter, Dennis L.
    CLINICAL BREAST CANCER, 2011, 11 (03) : 184 - 190
  • [26] Accelerated Partial Breast Irradiation with Intensity-Modulated Radiotherapy Is Feasible for Chinese Breast Cancer Patients
    He, Zhenyu
    Wu, Sangang
    Zhou, Juan
    Li, Fengyan
    Sun, Jiayan
    Lin, Qin
    Lin, Huanxin
    Guan, Xunxing
    JOURNAL OF BREAST CANCER, 2014, 17 (03) : 256 - 264
  • [27] Cardiac avoidance in breast radiotherapy: a comparison of simple shielding techniques with intensity-modulated radiotherapy
    Landau, D
    Adams, EJ
    Webb, S
    Ross, G
    RADIOTHERAPY AND ONCOLOGY, 2001, 60 (03) : 247 - 255
  • [28] Long-Term Breast Cancer Patient Outcomes After Adjuvant Radiotherapy Using Intensity-Modulated Radiotherapy or Conventional Tangential Radiotherapy
    Yang, Jen-Fu
    Lee, Meei-Shyuan
    Lin, Chun-Shu
    Chao, Hsing-Lung
    Chen, Chang-Ming
    Lo, Cheng-Hsiang
    Fan, Chao-Yueh
    Tsao, Chih-Cheng
    Huang, Wen-Yen
    MEDICINE, 2016, 95 (11)
  • [29] Learning the relationship between patient geometry and beam intensity in breast intensity-modulated radiotherapy
    Lu, RZ
    Radke, RJ
    Hong, L
    Chui, CS
    Xiong, JP
    Yorke, E
    Jackson, A
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2006, 53 (05) : 908 - 920
  • [30] Determination of patient set-up error and optimal treatment margin for intensity modulated radiotherapy using image guidance system
    Kanakavelu, Nithya
    Samuel, James Jebaseelan
    JOURNAL OF BUON, 2016, 21 (02): : 505 - 511