A simulation of the effects of set-up error and changes in breast volume on conventional and intensity-modulated treatments in breast radiotherapy

被引:16
|
作者
Hector, C
Webb, S
Evans, PM
机构
[1] Inst Canc Res, Joint Dept Phys, Sutton SM2 5PT, Surrey, England
[2] Royal Marsden NHS Trust, Sutton SM2 5PT, Surrey, England
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2001年 / 46卷 / 05期
关键词
D O I
10.1088/0031-9155/46/5/309
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The effect of interfractional patient movement on dosimetry has been investigated for breast radiotherapy. Errors in patient set-up and changes in breast volume were simulated individually to determine how each contributes to the total dosimetric error. Two treatment techniques were investigated: a conventional treatment and an intensity-modulated treatment delivered using compensators. Six patients were investigated and anterior-posterior (AP) and superior-inferior (SI) displacements were simulated by displacing the isocentre in both directions by 2, 5 and 10 mm. A model of the breast was developed from the six patients to simulate changes in breast volume. In this model, the breast was described as a set of semi-ellipses. The volume of the breast was changed by varying the magnitude of the semi-major and semi-minor axes. Anisotropic changes in breast volume were also investigated. The dosimetric error was evaluated for each dose plan by calculating the volume outside the 95-105% dose range resulting from the simulations. A number of parameters describing the size and shape of the breast were also investigated to determine whether a susceptibility of outline sets to interfractional patient movement could be predicted. A parameter describing the increase in the breast volume outside the 95-105% dose range was calculated for AP and SI set-up errors of +/-3 mm and changes in breast volume of 5%. Results revealed that set-up errors were likely to cause larger increases in the volume outside the 95-105% dose range than changes in breast volume for typical set-up errors and changes in breast volume that occur during treatment. The magnitude of the set-up errors and changes in breast volume were observed to be dependent on the shape outline set. Statistically significant linear correlation was observed between the increase in the volume outside the 95-105% dose range and several of the evaluation parameters.
引用
收藏
页码:1451 / 1471
页数:21
相关论文
共 50 条
  • [1] The dosimetric consequences of inter-fractional patient movement on conventional and intensity-modulated breast radiotherapy treatments
    Hector, CL
    Webb, S
    Evans, PM
    RADIOTHERAPY AND ONCOLOGY, 2000, 54 (01) : 57 - 64
  • [2] Intensity-modulated Radiotherapy for the Treatment of Breast Cancer
    Coles, C. E.
    Donovan, E.
    Haviland, J.
    Yarnold, J.
    CLINICAL ONCOLOGY, 2013, 25 (03) : 215 - 215
  • [3] Dosimetric absorption of intensity-modulated radiotherapy compared with conventional radiotherapy in breast-conserving surgery
    Lin, Yang
    Wang, Benzhong
    ONCOLOGY LETTERS, 2015, 9 (01) : 9 - 14
  • [4] ACCELERATED WHOLE BREAST IRRADIATION WITH INTENSITY-MODULATED RADIOTHERAPY TO THE PRONE BREAST
    Croog, Victoria J.
    Wu, Abraham J.
    Mccormick, Beryl
    Beal, Kathryn P.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 73 (01): : 88 - 93
  • [5] Skin-sparing intensity-modulated radiotherapy of the breast
    Vordermark, Dirk
    JOURNAL OF CLINICAL ONCOLOGY, 2008, 26 (19) : 3292 - 3292
  • [6] Skin-Sparing Intensity-Modulated Radiotherapy of the Breast
    Boelke, Edwin
    Matuschek, Christiane
    Gripp, Stephan
    Budach, Wilfried
    Gerber, Peter Arne
    Peiper, Matthias
    JOURNAL OF CLINICAL ONCOLOGY, 2008, 26 (32) : 5305 - 5306
  • [7] Intensity-modulated breast radiotherapy: the new standard of care?
    Pierce, LJ
    BREAST CANCER RESEARCH AND TREATMENT, 2003, 82 : S3 - S3
  • [8] Contralateral breast dose in conventional and intensity modulated radiotherapy
    Burmeister, J
    Alvarado, N
    McDermott, P
    Way, S
    Bossenberger, T
    Jaenisch, H
    Patel, R
    Washington, T
    MEDICAL PHYSICS, 2005, 32 (06) : 2060 - 2061
  • [9] Intensity-Modulated Radiotherapy for Breast Cancer: Advances in Whole and Partial Breast Treatment
    White, Julia R.
    Meyer, John L.
    IMRT IGRT SBRT- ADVANCES IN THE TREATMENT PLANNING AND DELIVERY OF RADIOTHERAPY, 2011, 43 : 292 - 314
  • [10] A Dosimetric Comparison of Conventional Intensity-Modulated Radiotherapy and Volumetric Modulated Arc Radiotherapy for Left-Breast Cancer after Breast-Conserving Surgery
    Sun, T.
    Yin, Y.
    Lin, X.
    Lu, J.
    Liu, T.
    Chen, J.
    Ma, C.
    MEDICAL PHYSICS, 2010, 37 (06)