Distal interphalangeal joint arthrodesis with a headless compression screw: morphometric and functional analyses

被引:23
|
作者
Song, Joo-Hyoun [2 ]
Lee, Joo-Yup [2 ]
Chung, Yang-Guk [3 ]
Park, Il-Jung [1 ]
机构
[1] Catholic Univ Korea, Bucheon St Marys Hosp, Dept Orthoped Surg, Puchon 420717, South Korea
[2] Catholic Univ Korea, St Vincent Hosp, Dept Orthoped Surg, Suwon 442723, South Korea
[3] Catholic Univ Korea, Seoul St Marys Hosp, Dept Orthoped Surg, Seoul, South Korea
关键词
Distal interphalangeal joint; Arthrodesis; Headless compression screw; ARTHROPLASTY; COMPLICATIONS; FIXATION; HAND;
D O I
10.1007/s00402-011-1413-3
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We performed radiologic measurement of the distal and middle phalanges in volunteers to determine the size of a headless compression screw suitable for distal interphalangeal (DIP) joint arthrodesis in Korean subjects and report on clinical results using an acutrak fusion screw. Radiologic measurements on the distal and middle phalanx were performed to determine the optimal size of screw. Five hundred fingers from 50 adult Koreans without any abnormality on plain radiographs were selected and anteroposterior and lateral radiographs were obtained for measurements. For the distal phalanx, the narrowest diameter of the cortical bone was measured to determine the minimal diameter of the screw that would not penetrate the cortex. For the middle phalanx, the narrowest diameter of the medullary canal was measured to determine the appropriate size of the screw for fixation. Between May 2004 and December 2007, there were 23 fingers in 22 patients (6 male, 16 female) that had finger DIP joint or thumb IP joint arthrodesis performed with the acutrak fusion screws. At the final follow up, time to union, complications, clinical fusion angle, pinch power, visual analogue score (VAS) for pain and the Korean version of the disabilities of the arm, shoulder and hand (DASH) questionnaire were assessed. In the distal phalanx, the narrowest diameter of the cortex was 2.64 +/- A 0.51 mm for the little finger. In the middle phalanx, the narrowest diameter of the medullary canal was 1.83 +/- A 0.50 mm for the little finger and 4.17 +/- A 0.68 for the thumb. The mean time to union was 10 weeks (range 8-12). The mean clinical fusion angle of the DIP joint was 11.9A degrees (range 0-20). The VAS pain score was 0.4 (range 0-3). Pinch power was 75% of the normal side. The average Korean DASH score was 5 points (range 0-8). We experienced one intraoperative fixation failure for thumb IP joint arthrodesis caused by a wide medullary canal of the proximal phalanx. The acutrak fusion screw was a feasible and adequate tool for DIP arthrodesis, particularly in Koreans. However, meticulous attention to technique was important to avoid complications in some little fingers. If preoperative radiographs suggest the thumb has a wide medullary canal, alternate methods of fixation should be considered.
引用
收藏
页码:663 / 669
页数:7
相关论文
共 50 条
  • [41] Arthrodesis of distal interphalangeal and thumb interphalangeal joint: a retrospective cohort study of 149 cases
    Philip Silvano
    Evelina Pantzar-Castilla
    Eva Lundqvist
    BMC Musculoskeletal Disorders, 25
  • [42] Transfixation cast technique for arthrodesis of the distal interphalangeal joint of horses
    Easter, J. L.
    Schumacher, J.
    Watkins, J. P.
    VETERINARY AND COMPARATIVE ORTHOPAEDICS AND TRAUMATOLOGY, 2011, 24 (01) : 62 - 67
  • [43] Distal interphalangeal joint arthrodesis comparing tension-band wire and Herbert screw: A biomechanical and dimensional analysis
    Wyrsch, B
    Dawson, J
    Weikert, D
    Milek, M
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1996, 21A (03): : 438 - 443
  • [44] Arthrodesis of distal interphalangeal and thumb interphalangeal joint: a retrospective cohort study of 149 cases
    Silvano, Philip
    Pantzar-Castilla, Evelina
    Lundqvist, Eva
    BMC MUSCULOSKELETAL DISORDERS, 2024, 25 (01)
  • [45] Factors Influencing Bone Union in Finger Distal Interphalangeal and Thumb Interphalangeal Joint Arthrodesis
    Heinonen, Aaro
    Leppanen, Olli
    Huhtala, Heini
    Karjalainen, Teemu
    Jokihaara, Jarkko
    JOURNAL OF HAND SURGERY-ASIAN-PACIFIC VOLUME, 2020, 25 (02): : 184 - 191
  • [46] Alternative to the distal interphalangeal joint arthrodesis: Lateral approach and plate fixation
    Mantovani, Gustavo
    Fukushirna, Walter Y.
    Cho, Alvaro Baik
    Aita, Marcio A.
    Lino, Waldo, Jr.
    Faria, Fabiano Nunes
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2008, 33A (01): : 31 - 34
  • [47] Distal interphalangeal Joint Arthrodesis using only Kirschner Wires in small distal Phalanges
    Lee, Jun-Ku
    Lee, Soonchul
    Choi, SeongJu
    Han, Dong Hun
    Oh, Jongbeom
    Kil, Minkyu
    Han, Soo-Hong
    HANDCHIRURGIE MIKROCHIRURGIE PLASTISCHE CHIRURGIE, 2021, 53 (05) : 462 - 466
  • [48] Arthrodesis of the distal interphalangeal joint using a bioabsorbable rod as an intramedullary nail
    Arata, J
    Ishikawa, K
    Soeda, H
    Kitayama, T
    SCANDINAVIAN JOURNAL OF PLASTIC AND RECONSTRUCTIVE SURGERY AND HAND SURGERY, 2003, 37 (04): : 228 - 231
  • [49] COMPARISON BETWEEN K-WIRE AND COMPRESSION SCREW FIXATION AFTER ARTHODESIS OF DISTAL INTERPHALANGEAL JOINT
    ENGEL, J
    TSUR, H
    FARIN, I
    PLASTIC AND RECONSTRUCTIVE SURGERY, 1977, 60 (04) : 611 - 614
  • [50] Dorsal Plate Fixation for Distal Interphalangeal Joint Arthrodesis of the Fingers and Thumb
    Patel, Anand
    Damodar, Dhanur
    Dodds, Seth D.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2018, 43 (11): : 1046.e1 - 1046.e6