摘要
We performed radiologic measurement of the distal and middle phalanges in volunteers to determine the size of a headless compression screw suitable for distal interphalangeal (DIP) joint arthrodesis in Korean subjects and report on clinical results using an acutrak fusion screw. Radiologic measurements on the distal and middle phalanx were performed to determine the optimal size of screw. Five hundred fingers from 50 adult Koreans without any abnormality on plain radiographs were selected and anteroposterior and lateral radiographs were obtained for measurements. For the distal phalanx, the narrowest diameter of the cortical bone was measured to determine the minimal diameter of the screw that would not penetrate the cortex. For the middle phalanx, the narrowest diameter of the medullary canal was measured to determine the appropriate size of the screw for fixation. Between May 2004 and December 2007, there were 23 fingers in 22 patients (6 male, 16 female) that had finger DIP joint or thumb IP joint arthrodesis performed with the acutrak fusion screws. At the final follow up, time to union, complications, clinical fusion angle, pinch power, visual analogue score (VAS) for pain and the Korean version of the disabilities of the arm, shoulder and hand (DASH) questionnaire were assessed. In the distal phalanx, the narrowest diameter of the cortex was 2.64 +/- A 0.51 mm for the little finger. In the middle phalanx, the narrowest diameter of the medullary canal was 1.83 +/- A 0.50 mm for the little finger and 4.17 +/- A 0.68 for the thumb. The mean time to union was 10 weeks (range 8-12). The mean clinical fusion angle of the DIP joint was 11.9A degrees (range 0-20). The VAS pain score was 0.4 (range 0-3). Pinch power was 75% of the normal side. The average Korean DASH score was 5 points (range 0-8). We experienced one intraoperative fixation failure for thumb IP joint arthrodesis caused by a wide medullary canal of the proximal phalanx. The acutrak fusion screw was a feasible and adequate tool for DIP arthrodesis, particularly in Koreans. However, meticulous attention to technique was important to avoid complications in some little fingers. If preoperative radiographs suggest the thumb has a wide medullary canal, alternate methods of fixation should be considered.
引用
收藏
页码:663 / 669
页数:7
相关论文
共 50 条
  • [21] Correction: Distal interphalangeal joint arthrodesis with nonaxial multiple small screws: a biomechanical analysis with axial headless compression screw and clinical result of 15 consecutive cases
    Seung Hun Woo
    Sang Ho Kwak
    Hyo Seok Jang
    Dong Hee Kim
    Jang Hyeon Seo
    Sang Hyun Lee
    BMC Musculoskeletal Disorders, 24
  • [22] Silicone arthroplasty versus screw arthrodesis in distal interphalangeal joint osteoarthritis
    Neukom, Lisa
    Marks, Miriam
    Hensler, Stefanie
    Kundig, Sylvia
    Herren, Daniel B.
    Schindele, Stephan
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2020, 45 (06) : 615 - 621
  • [23] ARTHRODESIS OF DISTAL INTERPHALANGEAL JOINT AND OF INTERPHALANGEAL JOINT OF THUMB BY SCREWING
    HEIM, U
    OSTERWALDER, M
    ANNALES DE CHIRURGIE, 1977, 31 (04): : 291 - 294
  • [24] Distal Interphalangeal Joint Arthrodesis in Seven Cattle Using the Acutrak Plus Screw
    Lewis, Andrew J.
    Sod, Gary A.
    Gill, Marjorie S.
    Mitchell, Colin F.
    VETERINARY SURGERY, 2009, 38 (05) : 659 - 663
  • [25] Combined Distal Interphalangeal Joint Arthrodesis With Proximal Interphalangeal Joint Arthroplasty or Arthrodesis: Technical Considerations
    Dukan, Ruben
    Pichard, Remy
    Ng, Zhi Yang
    Shekouhi, Ramin
    Chim, Harvey
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2025, 50 (02): : 223 - 229
  • [26] USE OF A HERBERT SCREW FOR INTERPHALANGEAL JOINT ARTHRODESIS
    KATZMAN, SS
    GIBEAULT, JD
    DICKSON, K
    THOMPSON, JD
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1993, (296) : 127 - 132
  • [27] PROXIMAL INTERPHALANGEAL JOINT ARTHRODESIS WITH THE HERBERT SCREW
    AYRES, JR
    GOLDSTROHM, GL
    MILLER, GJ
    DELL, PC
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1988, 13A (04): : 600 - 603
  • [28] DISTAL INTERPHALANGEAL JOINT ARTHRODESIS - AN ANALYSIS OF COMPLICATIONS
    STERN, PJ
    FULTON, DB
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1992, 17A (06): : 1139 - 1145
  • [29] Distal interphalangeal joint arthrodesis with nonaxial multiple small screws: a biomechanical analysis with axial headless compression screw and clinical result of 15 consecutive cases (vol 23, 504, 2022)
    Woo, Seung Hun
    Kwak, Sang Ho
    Jang, Hyo Seok
    Kim, Dong Hee
    Seo, Jang Hyeon
    Lee, Sang Hyun
    BMC MUSCULOSKELETAL DISORDERS, 2023, 24 (01)
  • [30] Antibiotic Prophylaxis for Distal Interphalangeal Joint Arthrodesis
    Vohra, Sahil F.
    Beck, Jadon H.
    Barrett, Patrick C.
    Bravo, Cesar J.
    Apel, Peter J.
    PLASTIC AND RECONSTRUCTIVE SURGERY-GLOBAL OPEN, 2023, 11 (03)