Enhanced computational modelling of UHMWPE wear in total hip joint replacements: The role of frictional work and contact pressure

被引:16
|
作者
Liu, Feng [1 ]
He, Ying [1 ]
Gao, Zirui [1 ]
Jiao, Duoduo [1 ]
机构
[1] North Univ China, Sch Mech Engn, Taiyuan, Peoples R China
关键词
Implant failure; Friction; Highly cross-linked UHMWPE; Artificial joint; Cross shear; Arthroplasty; MOLECULAR-WEIGHT POLYETHYLENE; CROSS-SHEAR; SIMULATION; PREDICTION; STRESS; MOTION; QUANTIFICATION; OSTEOLYSIS; FRAMEWORK; CREEP;
D O I
10.1016/j.wear.2021.203985
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Hip joint replacements using highly cross-linked ultra-high-molecular-weight polyethylene (UHMWPE) as a bearing material offer an effective treatment to arthritis. However, the bearing wear may affect the longevity of implants which requires more rigorous investigations. UHMWPE wear is highly dependent on cross-shear (CS) as a result of the multidirectional motion of bearings. Previously, a wear model has been developed with the potential to provide accurate simulation, of which the wear was determined as an exponential function of sliding distance with CS at the crossing angle of 90 degrees, and the effect of CS for an arbitrary angle was quantified to be proportional to the perpendicular component of sliding distance. In the present study, the wear was proposed as the exponential function of frictional work. In particular, contact pressure was incorporated into the calculation of frictional work by considering that the friction coefficient is a function of contact pressure. In addition, the CS quantification for arbitrary crossing angles was considered by coupling the sliding distance and frictional force. The computational formulations of the present and previous models were compared by applying the models to a 36 mm diameter metal-on-polyethylene total hip prosthesis with highly cross-linked UHMWPE at 5 Mrad irradiation under simulated walking conditions. The simulation was also validated against the published results of hip simulator tests with respect to the influence of motion/loading condition on wear. The study showed markedly improved computational predictions with wear rate discrepancies in the range of 8-25% for two kinematic conditions either with the fixed or with varying direction of load. The results show the important role of both the frictional work and contact pressure, and they should be both incorporated appropriately to enhance the computational modelling.
引用
收藏
页数:8
相关论文
共 45 条
  • [31] The influence of cross shear and contact pressure on the wear of UHMWPE-on-PEEK-OPTIMATM for use in total knee replacement
    Cowie, Raelene M.
    Briscoe, Adam
    Jennings, Louise M.
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2023, 148
  • [32] Wear Behaviour of UHMWPE Against DC-Pulsed Plasma Nitrided and Duplex Treated AISI 316L Used in Hip Joint Replacements
    Perez, Ezequiel
    Pazos, Leonardo
    De las Heras, Evangelina
    Parodi, Belen
    Corengia, Pablo
    Braceras, Inigo
    PLASMA PROCESSES AND POLYMERS, 2009, 6 : S75 - S80
  • [33] The effect of cup inclination and wear on the contact mechanics and cement fixation for ultra high molecular weight polyethylene total hip replacements
    Hua, Xijin
    Wroblewski, B. Michael
    Jin, Zhongmin
    Wang, Ling
    MEDICAL ENGINEERING & PHYSICS, 2012, 34 (03) : 318 - 325
  • [34] Is the wear factor in total joint replacements dependent on the nominal contact stress in ultra-bigh molecular weight polyethylene contacts?
    Vassiliou, K
    Unsworth, A
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2004, 218 (H2) : 101 - 107
  • [35] Enhanced Wear and Corrosion in Modular Tapers in Total Hip Replacement Is Associated With the Contact Area and Surface Topography
    Panagiotidou, Anna
    Meswania, Jay
    Hua, Jia
    Muirhead-Allwood, Sarah
    Hart, Alister
    Blunn, Gordon
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2013, 31 (12) : 2032 - 2039
  • [36] Improved wear, mechanical, and biological behavior of UHMWPE-HAp-zirconia hybrid nanocomposites with a prospective application in total hip joint replacement
    Meysam Salari
    Sara Mohseni Taromsari
    Reza Bagheri
    Mohammad Ali Faghihi Sani
    Journal of Materials Science, 2019, 54 : 4259 - 4276
  • [37] Improved wear, mechanical, and biological behavior of UHMWPE-HAp-zirconia hybrid nanocomposites with a prospective application in total hip joint replacement
    Salari, Meysam
    Taromsari, Sara Mohseni
    Bagheri, Reza
    Sani, Mohammad Ali Faghihi
    JOURNAL OF MATERIALS SCIENCE, 2019, 54 (05) : 4259 - 4276
  • [38] Fourier transform infrared spectroscopic imaging of wear and corrosion products within joint capsule tissue from total hip replacements patients
    Liu, Songyun
    Hall, Deborah J.
    McCarthy, Stephanie M.
    Jacobs, Joshua J.
    Urban, Robert M.
    Pourzal, Robin
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2020, 108 (02) : 513 - 526
  • [39] Soft-Tissue Balance Evaluation System for Total Hip Arthroplasty by Intraoperative Contact Pressure Measurement at the Hip Joint
    Otake, Yoshito
    Suzuki, Naoki
    Hattori, Asaki
    Hayashibe, Mitsuhiro
    Miki, Hidenobu
    Yamamura, Mitsuyoshi
    Sugano, Nobuhiko
    Yonenobu, Kazuo
    Ochi, Takahiro
    MEDICINE MEETS VIRTUAL REALITY 14: ACCELERATING CHANGE IN HEALTHCARE: NEXT MEDICAL TOOLKIT, 2006, 119 : 416 - +
  • [40] In-vitro and in-silico investigations on the influence of contact pressure on cross-linked polyethylene wear in total knee replacements
    O'Brien, Sean T.
    Luo, Yunhua
    Brandt, Jan-M.
    WEAR, 2015, 332 : 687 - 693