Enhanced computational modelling of UHMWPE wear in total hip joint replacements: The role of frictional work and contact pressure

被引:16
|
作者
Liu, Feng [1 ]
He, Ying [1 ]
Gao, Zirui [1 ]
Jiao, Duoduo [1 ]
机构
[1] North Univ China, Sch Mech Engn, Taiyuan, Peoples R China
关键词
Implant failure; Friction; Highly cross-linked UHMWPE; Artificial joint; Cross shear; Arthroplasty; MOLECULAR-WEIGHT POLYETHYLENE; CROSS-SHEAR; SIMULATION; PREDICTION; STRESS; MOTION; QUANTIFICATION; OSTEOLYSIS; FRAMEWORK; CREEP;
D O I
10.1016/j.wear.2021.203985
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Hip joint replacements using highly cross-linked ultra-high-molecular-weight polyethylene (UHMWPE) as a bearing material offer an effective treatment to arthritis. However, the bearing wear may affect the longevity of implants which requires more rigorous investigations. UHMWPE wear is highly dependent on cross-shear (CS) as a result of the multidirectional motion of bearings. Previously, a wear model has been developed with the potential to provide accurate simulation, of which the wear was determined as an exponential function of sliding distance with CS at the crossing angle of 90 degrees, and the effect of CS for an arbitrary angle was quantified to be proportional to the perpendicular component of sliding distance. In the present study, the wear was proposed as the exponential function of frictional work. In particular, contact pressure was incorporated into the calculation of frictional work by considering that the friction coefficient is a function of contact pressure. In addition, the CS quantification for arbitrary crossing angles was considered by coupling the sliding distance and frictional force. The computational formulations of the present and previous models were compared by applying the models to a 36 mm diameter metal-on-polyethylene total hip prosthesis with highly cross-linked UHMWPE at 5 Mrad irradiation under simulated walking conditions. The simulation was also validated against the published results of hip simulator tests with respect to the influence of motion/loading condition on wear. The study showed markedly improved computational predictions with wear rate discrepancies in the range of 8-25% for two kinematic conditions either with the fixed or with varying direction of load. The results show the important role of both the frictional work and contact pressure, and they should be both incorporated appropriately to enhance the computational modelling.
引用
收藏
页数:8
相关论文
共 45 条
  • [21] The relationship between contact pressure, insert thickness, and mild wear in total knee replacements
    Bei, Y
    Fregly, BJ
    Sawyer, WG
    Banks, SA
    Kim, NH
    CMES-COMPUTER MODELING IN ENGINEERING & SCIENCES, 2004, 6 (02): : 145 - 152
  • [22] Computational modelling of the fossa component fixation associated with alloplastic total temporomandibular joint replacements
    Shen, Zhenhao
    Zhang, Pengyu
    Cheng, Bo
    Liu, Feng
    He, Dongmei
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2023, 147
  • [23] 3-dimensional sliding/contact computational simulation of total hip wear
    Maxian, TA
    Brown, TD
    Pedersen, DR
    Callaghan, JJ
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1996, (333) : 41 - 50
  • [24] A computational parametric study on edge loading in ceramic-on-ceramic total hip joint replacements
    Liu, Feng
    Feng, Li
    Wang, Junyuan
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2018, 83 : 135 - 142
  • [25] A computational approach to fretting wear prediction at the head-stem taper junction of total hip replacements
    English, Russell
    Ashkanfar, Ariyan
    Rothwell, Glynn
    WEAR, 2015, 338 : 210 - 220
  • [26] Distribution of polyethylene wear particles and bone fragments in periprosthetic tissue around total hip joint replacements
    Zolotarevova, E.
    Entlicher, G.
    Pavlova, E.
    Slouf, M.
    Pokorny, D.
    Vesely, F.
    Gallo, J.
    Sosna, A.
    ACTA BIOMATERIALIA, 2010, 6 (09) : 3595 - 3600
  • [27] Wear and deformation of ceramic-on-polyethylene total hip replacements with joint laxity and swing phase microseparation
    Williams, S
    Butterfield, M
    Stewart, T
    Ingham, E
    Stone, M
    Fisher, J
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2003, 217 (H2) : 147 - 153
  • [28] Reducing the Wear of the UHMWPE Used in the Total Hip Replacement after Low-Pressure Plasma Treatment
    Pakhaliuk, Vladimir Ivanovich
    Vasilets, Victor Nikolaevich
    Poliakov, Aleksandr Mikhailovich
    Torkhov, Nikolay Anatolevich
    JOURNAL OF APPLIED AND COMPUTATIONAL MECHANICS, 2022, 8 (03): : 1035 - 1042
  • [29] Particles and Ions Generated in Total Hip Joint Prostheses: In Vitro Wear Test Results of UHMWPE and XLPE Acetabular Components
    Zohdi, Hamoon
    Andreatta, Benjamin
    Heuberger, Roman
    TRIBOLOGY LETTERS, 2017, 65 (03)
  • [30] Particles and Ions Generated in Total Hip Joint Prostheses: In Vitro Wear Test Results of UHMWPE and XLPE Acetabular Components
    Hamoon Zohdi
    Benjamin Andreatta
    Roman Heuberger
    Tribology Letters, 2017, 65