Cascaded systems analysis of anatomic noise in digital mammography and dual-energy digital mammography

被引:6
|
作者
Tanguay, Jesse [1 ]
Lalonde, Robert [1 ]
Bjarnason, Thorarin A. [2 ,3 ,4 ]
Yang, Chang-Ying Joseph [2 ,5 ]
机构
[1] Ryerson Univ, Dept Phys, Toronto, ON, Canada
[2] Univ British Columbia Okanagan, Dept Phys, Kelowna, BC, Canada
[3] Interior Hlth, Med Imaging, Kelowna, BC, Canada
[4] Univ British Columbia, Dept Radiol, Vancouver, BC, Canada
[5] BC Canc Kelowna, Kelowna, BC, Canada
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2019年 / 64卷 / 21期
基金
加拿大自然科学与工程研究理事会;
关键词
mammography; breast imaging; image quality; noise power spectrum; medical imaging; dual-energy imaging; DETECTIVE QUANTUM EFFICIENCY; OPTIMIZATION; TOMOSYNTHESIS; SIGNAL; MODEL; DETECTABILITY; PROPAGATION; VALIDATION; PARAMETERS; SPECTRA;
D O I
10.1088/1361-6560/ab3fcd
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In x-ray based imaging of the breast, contrast between fibroglandular (Fg) tissue and adipose (Ad) tissue is a source of anatomic noise. The goal of this work was to validate by simulation and experiment a mathematical framework for modelling the Fg component of anatomic noise in digital mammograpy (DM) and dual-energy (DE) DM. Our mathematical framework unifies and generalizes existing approaches. We compared mathematical predictions directly with empirical measurements of the anatomic noise power spectrum of the CIRS BR3D structured breast phantom using two clinical mammography systems and four beam qualities. Our simulation and experimental results showed agreement with mathematical predictions. As a demonstration of utility, we used our mathematical framework in a theoretical spectral optimization of DM for the task of detecting breast masses. Our theoretical optimization showed that the optimal tube voltage for DM may be higher than that based on predictions that do not account for anatomic noise, in agreement with recent theoretical findings. Additionally, our theoretical optimization predicts that filtering tungsten-anode x-ray spectra with rhodium has little influence on lesion detectability, in contrast with previous findings. The mathematical methods validated in this work can be incorporated easily into cascaded systems analysis of breast imaging systems and will be useful when optimizating novel techniques for x-ray-based imaging of the breast.
引用
收藏
页数:21
相关论文
共 50 条
  • [41] The relationship between anatomic noise and volumetric breast density for digital mammography
    Mainprize, James G.
    Tyson, Albert H.
    Yaffe, Martin J.
    MEDICAL PHYSICS, 2012, 39 (08) : 4660 - 4668
  • [42] Error analysis of calibration materials on dual-energy mammography
    Mou, Xuanqin
    Chen, Xi
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION- MICCAI 2007, PT 2, PROCEEDINGS, 2007, 4792 : 596 - +
  • [43] A study on dual-energy subtraction mammography
    Ramírez, V
    Brandan, ME
    Ruiz-Trejo, C
    Márquez, JA
    Villaseñor, Y
    MEDICAL PHYSICS, 2004, 724 : 132 - 135
  • [44] Dual-energy mammography: simulation studies
    Bliznakova, K.
    Kolitsi, Z.
    Pallikarakis, N.
    PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (18): : 4497 - 4515
  • [45] Dual-energy in mammography - Feasibility study
    Jafroudi, H
    Lo, SC
    Li, HA
    Artz, DS
    Freedman, MT
    Mun, SK
    PHYSICS OF MEDICAL IMAGING: MEDICAL IMAGING 1996, 1996, 2708 : 278 - 293
  • [46] Dual-energy digital mammography for calcification imaging - Implementation under narrow-beam geometry
    Kappadath, S
    Shaw, C
    Liu, X
    Lai, C
    Balter, P
    Whitman, G
    MEDICAL PHYSICS, 2003, 30 (06) : 1455 - 1455
  • [47] AN ENERGY SENSITIVE CASSETTE FOR DUAL-ENERGY MAMMOGRAPHY
    CHAKRABORTY, DP
    BARNES, GT
    MEDICAL PHYSICS, 1986, 13 (04) : 573 - 573
  • [48] AN ENERGY SENSITIVE CASSETTE FOR DUAL-ENERGY MAMMOGRAPHY
    CHAKRABORTY, DP
    BARNES, GT
    MEDICAL PHYSICS, 1989, 16 (01) : 7 - 13
  • [49] Establishing a Quality Control protocol for dual-energy based contrast-enhanced digital mammography
    Cockmartin, L.
    Bosmans, H.
    Marshall, N. W.
    MEDICAL IMAGING 2021: PHYSICS OF MEDICAL IMAGING, 2021, 11595
  • [50] Dual-energy contrast enhanced digital mammography using a new approach for breast tissue canceling
    Puong, Sylvie
    Bouchevreau, Xavier
    Patoureaux, Fanny
    Iordache, Razvan
    Muller, Serge
    MEDICAL IMAGING 2007: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2007, 6510