Cascaded systems analysis of anatomic noise in digital mammography and dual-energy digital mammography

被引:6
|
作者
Tanguay, Jesse [1 ]
Lalonde, Robert [1 ]
Bjarnason, Thorarin A. [2 ,3 ,4 ]
Yang, Chang-Ying Joseph [2 ,5 ]
机构
[1] Ryerson Univ, Dept Phys, Toronto, ON, Canada
[2] Univ British Columbia Okanagan, Dept Phys, Kelowna, BC, Canada
[3] Interior Hlth, Med Imaging, Kelowna, BC, Canada
[4] Univ British Columbia, Dept Radiol, Vancouver, BC, Canada
[5] BC Canc Kelowna, Kelowna, BC, Canada
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2019年 / 64卷 / 21期
基金
加拿大自然科学与工程研究理事会;
关键词
mammography; breast imaging; image quality; noise power spectrum; medical imaging; dual-energy imaging; DETECTIVE QUANTUM EFFICIENCY; OPTIMIZATION; TOMOSYNTHESIS; SIGNAL; MODEL; DETECTABILITY; PROPAGATION; VALIDATION; PARAMETERS; SPECTRA;
D O I
10.1088/1361-6560/ab3fcd
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In x-ray based imaging of the breast, contrast between fibroglandular (Fg) tissue and adipose (Ad) tissue is a source of anatomic noise. The goal of this work was to validate by simulation and experiment a mathematical framework for modelling the Fg component of anatomic noise in digital mammograpy (DM) and dual-energy (DE) DM. Our mathematical framework unifies and generalizes existing approaches. We compared mathematical predictions directly with empirical measurements of the anatomic noise power spectrum of the CIRS BR3D structured breast phantom using two clinical mammography systems and four beam qualities. Our simulation and experimental results showed agreement with mathematical predictions. As a demonstration of utility, we used our mathematical framework in a theoretical spectral optimization of DM for the task of detecting breast masses. Our theoretical optimization showed that the optimal tube voltage for DM may be higher than that based on predictions that do not account for anatomic noise, in agreement with recent theoretical findings. Additionally, our theoretical optimization predicts that filtering tungsten-anode x-ray spectra with rhodium has little influence on lesion detectability, in contrast with previous findings. The mathematical methods validated in this work can be incorporated easily into cascaded systems analysis of breast imaging systems and will be useful when optimizating novel techniques for x-ray-based imaging of the breast.
引用
收藏
页数:21
相关论文
共 50 条
  • [21] DUAL-ENERGY DIGITAL MAMMOGRAPHY UTILIZING STIMULATED PHOSPHOR COMPUTED RADIOGRAPHY
    BRETTLE, DS
    COWEN, AR
    PHYSICS IN MEDICINE AND BIOLOGY, 1994, 39 (11): : 1989 - 2004
  • [22] Algorithmic scatter correction in dual-energy digital mammography for calcification imaging
    Chen, Xi
    Nishikawa, Robert M.
    Chan, Suk-tak
    Lau, Beverly A.
    Zhang, Lei
    Mou, Xuanqin
    MEDICAL IMAGING 2012: PHYSICS OF MEDICAL IMAGING, 2012, 8313
  • [23] DUAL-ENERGY MAMMOGRAPHY
    JOHNS, PC
    DROST, DJ
    YAFFE, MJ
    FENSTER, A
    JOURNAL OF THE CANADIAN ASSOCIATION OF RADIOLOGISTS-JOURNAL DE L ASSOCIATION CANADIENNE DES RADIOLOGISTES, 1984, 35 (01): : 98 - 98
  • [24] DUAL-ENERGY MAMMOGRAPHY - A DETECTOR ANALYSIS
    BOONE, JM
    SHABER, GS
    TECOTZKY, M
    MEDICAL PHYSICS, 1990, 17 (04) : 665 - 675
  • [25] A novel approach to background subtraction in contrast-enhanced dual-energy digital mammography with commercially available mammography devices: Noise minimization
    Contillo, Adriano
    Di Domenico, Giovanni
    Cardarelli, Paolo
    Gambaccini, Mauro
    Taibi, Angelo
    MEDICAL PHYSICS, 2016, 43 (06) : 3080 - 3089
  • [26] DQE of a digital mammography detector using cascaded linear systems analysis
    Williams, MB
    Simoni, PU
    Mangiafico, PA
    Stanton, MJ
    Phillips, WC
    Smilowitz, L
    RADIOLOGY, 1998, 209P : 160 - 160
  • [27] Contrast-enhanced dual-energy digital subtraction mammography: Optimization of the beam energy
    Kwan, ALC
    Boone, JM
    Le-Petross, H
    Lindfors, KK
    Seibert, JA
    Lewin, JM
    Medical Imaging 2005: Physics of Medical Imaging, Pts 1 and 2, 2005, 5745 : 1317 - 1321
  • [28] Dual-energy contrast-enhanced digital mammography: initial clinical results
    Dromain, Clarisse
    Thibault, Fabienne
    Muller, Serge
    Rimareix, Francoise
    Delaloge, Suzette
    Tardivon, Anne
    Balleyguier, Corinne
    EUROPEAN RADIOLOGY, 2011, 21 (03) : 565 - 574
  • [29] Dual-energy contrast-enhanced digital mammography: initial clinical results
    Clarisse Dromain
    Fabienne Thibault
    Serge Muller
    Françoise Rimareix
    Suzette Delaloge
    Anne Tardivon
    Corinne Balleyguier
    European Radiology, 2011, 21 : 565 - 574
  • [30] Dual-energy imaging in full-field digital mammography: a phantom study
    Taibi, A
    Fabbri, S
    Baldelli, P
    di Maggio, C
    Gennaro, G
    Marziani, M
    Tuffanelli, A
    Gambaccini, M
    PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (13): : 1945 - 1956