The relationship between anatomic noise and volumetric breast density for digital mammography

被引:20
|
作者
Mainprize, James G. [1 ]
Tyson, Albert H. [1 ]
Yaffe, Martin J. [1 ,2 ]
机构
[1] Sunnybrook Hlth Sci Ctr, Sunnybrook Res Inst, Toronto, ON M4N 3M5, Canada
[2] Univ Toronto, Dept Med Biophys, Toronto, ON M4N 3M5, Canada
关键词
digital mammography; anatomic noise; breast density; image analysis; CANCER RISK; THICKNESS; IMAGES; MODEL;
D O I
10.1118/1.4736422
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The appearance of parenchymal/stromal patterns in mammography have been characterized as having a Wiener power spectrum with an inverse power-law shape described by the exponential parameter, beta. The amount of fibroglandular tissue, which can be quantified in terms of volumetric breast density (VBD), influences the texture and appearance of the patterns formed in a mammogram. Here, a large study is performed to investigate the variations in beta in a clinical population and to indicate the relationship between beta and breast density. Methods: From a set of 2686 cranio-caudal normal screening mammograms, the parameter beta was extracted from log-log fits to the Wiener spectrum over the range 0.15-1 min(-1). The Wiener spectrum was calculated from regions of interest in the compression paddle contact region of the breast. An in-house computer program, Cumulus V, was used to extract the volumetric breast density and identify the compression paddle contact regions of the breast. The Wiener spectra were calculated with and without modulation transfer function (MTF) correction to determine the impact of VBD on the intrinsic anatomic noise. Results: The mean volumetric breast density was 25.5% (+/- 12.6%) over all images. The mean beta following a MTF correction which decreased the beta slightly (approximate to-0.08) was found to be 2.87. Varying the maximum of the spatial frequency range of the fits from 0.7 to 1.0, 1.25 or 1.5 mm(-1) showing small decreases in the result, although the effect of the quantum noise power component on reducing beta was clearly observed at 1.5 mm(-1). Conclusions: The texture parameter, beta, was found to increase with VBD at low volumetric breast densities with an apparent leveling off at higher densities. The relationship between beta and VBD measured here can be used to create probabilistic models for computer simulations of detectability. As breast density is a known risk predictor for breast cancer, the correlation between beta and VBD suggests that beta may provide predictive information and this will be investigated in the future. (C) 2012 American Association of Physicists in Medicine. [http://dx.doi.org/10.1118/1.4736422]
引用
收藏
页码:4660 / 4668
页数:9
相关论文
共 50 条
  • [1] Volumetric breast density affects performance of digital screening mammography
    Wanders, Johanna O. P.
    Holland, Katharina
    Veldhuis, Wouter B.
    Mann, Ritse M.
    Pijnappel, Ruud M.
    Peeters, Petra H. M.
    van Gils, Carla H.
    Karssemeijer, Nico
    BREAST CANCER RESEARCH AND TREATMENT, 2017, 162 (01) : 95 - 103
  • [2] Volumetric breast density affects performance of digital screening mammography
    Johanna O. P. Wanders
    Katharina Holland
    Wouter B. Veldhuis
    Ritse M. Mann
    Ruud M. Pijnappel
    Petra H. M. Peeters
    Carla H. van Gils
    Nico Karssemeijer
    Breast Cancer Research and Treatment, 2017, 162 : 95 - 103
  • [3] Relationship between mammography breast density and bone mineral density
    Gupta, R.
    Alhajri, F. A.
    Mohammed, A. M.
    Chavan, V. N. K.
    Gupta, P.
    JOURNAL OF CLINICAL DENSITOMETRY, 2008, 11 (03) : 431 - 436
  • [4] Volumetric breast density estimation method for full-field digital mammography
    Yang, J
    Rico, D
    Mawdsley, GE
    Yaffe, M
    RADIOLOGY, 2001, 221 : 192 - 192
  • [5] Comparison between software volumetric breast density estimates in breast tomosynthesis and digital mammography images in a large public screening cohort
    Fornvik, Daniel
    Fornvik, Hannie
    Fieselmann, Andreas
    Lang, Kristina
    Sartor, Hanna
    EUROPEAN RADIOLOGY, 2019, 29 (01) : 330 - 336
  • [6] Comparison between software volumetric breast density estimates in breast tomosynthesis and digital mammography images in a large public screening cohort
    Daniel Förnvik
    Hannie Förnvik
    Andreas Fieselmann
    Kristina Lång
    Hanna Sartor
    European Radiology, 2019, 29 : 330 - 336
  • [7] Relationship between volumetric breast density and socioeconomic status
    Samuels, L.
    Astley, S. M.
    Maxwell, A.
    Sergeant, J. C.
    Morris, J.
    Wilson, M.
    Stavrinos, P.
    Evans, D. G.
    Howell, A.
    Bydder, M.
    BREAST CANCER RESEARCH, 2013, 15
  • [8] Relationship Between the Age, Breast Density on Digital Mammography and the Risk of Breast Cancer and Benign Lesions in Chinese Women
    Du, T.
    Wang, Y.
    Zhang, C.
    Yu, S.
    Yan, Y.
    Wang, X.
    Zhang, W.
    Zhang, Y.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 192 (05)
  • [9] Cascaded systems analysis of anatomic noise in digital mammography and dual-energy digital mammography
    Tanguay, Jesse
    Lalonde, Robert
    Bjarnason, Thorarin A.
    Yang, Chang-Ying Joseph
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (21):
  • [10] A linear systems approach to modeling anatomic noise in digital mammography
    Lalonde, Robert
    Tanguay, Jesse
    MEDICAL IMAGING 2018: PHYSICS OF MEDICAL IMAGING, 2018, 10573