Advantages of gridless full-field digital mammography

被引:0
|
作者
Nykänen, K [1 ]
Siltanen, S [1 ]
机构
[1] Instrumentarium Corp, Imaging Div, FIN-04301 Tuusula, Finland
关键词
amorphous selenium; X-ray scattering; scatter fraction; scatter-to-primary ratio; full-field digital mammography; point spread function; edge spread function; grid; convolution;
D O I
10.1117/12.479944
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The purpose of the study was to find out whether the image quality in full-field digital mammography can be improved while lowering the patient dose by removing the anti-scatter grid. Moreover, a fast approximate computational algorithm was developed for determining the scattered field in a real mammogram. The method is non-iterative, robust against noise, and works without modification for any scatter-to-primary ratio. Furthermore, it is computationally effective since it is based on fast Fourier transform (FFT). It was found out that the wide dynamic range of digital detectors leads to decrease in patient dose from 10.9% up to 46.6.% at breast thickness of 2cm and from 0.8% up to 40.8% at breast thickness of 4cm depending on the efficiency of the removed grid. At constant patient dose the increase in contrast-to-noise ratio is 5.8% - 36.9% and 0.4%-30.0% accordingly at those two breast thickness. The convolution-based X-ray scatter model was considered. The developed scatter removal method was demonstrated with simulated mammograms and applied to clinical full-field digital mammograms acquired with a high-end digital flat panel detector based on amorphous selenium. Errors in reconstructed scattered fields were 0.3% in case of an ideal simulated mammogram and 7.4% in case of a real simulated mammogram (3cm breast). Applications where the scattered field needs to be determined include 3-D mammography and dual-energy breast imaging. In screening mammography gray-scale optimization eliminates the effect of scattering.
引用
收藏
页码:137 / 146
页数:10
相关论文
共 50 条
  • [21] Comparison of the microcalcifications between full-field digital mammography and screen film mammography
    Tohno, E
    Kujiraoka, Y
    Watanabe, Y
    Itai, Y
    RADIOLOGY, 2001, 221 : 189 - 189
  • [22] CCD-based detector for full-field digital mammography
    Stanton, M
    Phillips, W
    Stewart, A
    Smilowitz, L
    Williams, MB
    Simoni, P
    Ingersoll, C
    McCauley, T
    Qian, H
    MEDICAL IMAGING 1999: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 1999, 3659 : 740 - 748
  • [23] Digital luminescence mammography (CR) versus full-field digital mammography (DR): A phantom study
    Schulz-Wendtland, RW
    Aichinger, UG
    Lell, MM
    Kuchar, I
    Tartsch, M
    Bautz, WA
    RADIOLOGY, 2002, 225 : 416 - 417
  • [24] Baseline Screening Mammography: Performance of Full-Field Digital Mammography Versus Digital Breast Tomosynthesis
    McDonald, Elizabeth S.
    McCarthy, Anne Marie
    Akhtar, Amana L.
    Synnestvedt, Marie B.
    Schnall, Mitchell
    Conant, Emily F.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2015, 205 (05) : 1143 - 1148
  • [25] Enhancement of microcalcifications in full-field digital mammography by energy subtraction
    Diekmann, F
    Diekmann, S
    Bick, U
    Hamm, B
    DIGITAL MAMMOGRAPHY, PROCEEDINGS, 2003, : 577 - 580
  • [26] Full-field digital mammography on LCD versus CRT monitors
    Zuley, Margarita L.
    Willison, Kathleen M.
    Bonaccio, Ermelinda
    Miller, David P.
    Leong, David L.
    Seifert, Posy J.
    Somerville, Patricia
    Destounis, Stamatia
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2006, 187 (06) : 1492 - 1498
  • [27] Diagnostic value of full-field digital mammography for breast tumors
    Ji, T.
    Huang, T.
    Wang, Y.
    Zhu, G.
    Zhou, B.
    Shao, Q.
    BASIC & CLINICAL PHARMACOLOGY & TOXICOLOGY, 2019, 125 : 42 - 42
  • [28] Development of a quality control system for full-field digital mammography
    Yaffe, MJ
    Williams, MB
    Niklason, LT
    Mawdsley, GE
    Maidment, AD
    RADIOLOGY, 1998, 209P : 160 - 160
  • [29] Full-field digital mammography - System development and technical performance
    Yaffe, MJ
    Plewes, DB
    Mawdsley, GE
    Critten, J
    Feig, SA
    Maidment, ADA
    Picarro, M
    Tesic, M
    DIGITAL MAMMOGRAPHY '96, 1996, 1119 : 125 - 131
  • [30] X-ray scattering in full-field digital mammography
    Nykänen, K
    Siltanen, S
    MEDICAL PHYSICS, 2003, 30 (07) : 1864 - 1873