Optimized use and calibration of autocollimators in deflectometry - art. no. 670407

被引:29
|
作者
Geckeler, Ralf D. [1 ]
Just, Andreas [1 ]
机构
[1] Phys Tech Bundesanstalt Braunschweig & Berlin PTB, D-38116 Braunschweig, Germany
关键词
deflectometry; autocollimator; angle; angle calibration; traceability; flatness standard; precision metrology;
D O I
10.1117/12.732384
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Accurate and traceable angle measurement poses a central challenge to deflectometric profilometry. High-resolution electronic autocollimators are capable of providing accurate angle metrology for this purpose. The optimized calibration and the use of autocollimators under well-defined and stable measurement. conditions are central to their proper application.. To illustrate these issues, the autocollimator in use in the Extended Shear Angle Difference (ESAD) device for the absolute and traceable topography measurement of optical surfaces built at the Physikalisch-Technische Bundesanstalt (PTB) is considered. In contrast to other deflectometric profilers, ESAD combines deflectometric and shearing techniques in a unique way to minimize measurement errors and to optimize measurand traceability. Sub-nanometer repeatability, reproducibility, and uncertainty of the topography measurement are achieved for scans across near-flat surfaces up to 500 mm in diameter. In this paper, the ESAD shearing deflectometer and its measuring capabilities are presented. Information on the optimized use and accurate calibration of autocollimators for deflectometric applications is provided. The calibration of autocollimators by comparison with the highly accurate primary angle standard of PTB is illustrated. Factors influencing their angle response are discussed, such as the position of the aperture stop both along the autocollimator's optical axis and perpendicular to it.
引用
收藏
页码:70407 / 70407
页数:12
相关论文
共 50 条
  • [21] Optimized in situ construction of oligomers on an array surface -: art. no. e107
    Tolonen, AC
    Albeanu, DF
    Corbett, JF
    Handley, H
    Henson, C
    Malik, P
    NUCLEIC ACIDS RESEARCH, 2002, 30 (20) : e107
  • [22] Optimized LOWESS normalization parameter selection for DNA microarray data -: art. no. 194
    Berger, JA
    Hautaniemi, S
    Järvinen, AK
    Edgren, H
    Mitra, SK
    Astola, J
    BMC BIOINFORMATICS, 2004, 5 (1)
  • [23] Report on GOES SXI/XRS calibration effort - art. no. 66890J
    Reinard, Alysha
    Hill, Steven
    Bailey, Scott
    Pizzo, Victor
    Viereck, Rodney
    SOLAR PHYSICS AND SPACE WEATHER INSTRUMENTATION II, 2007, 6689 : J6890 - J6890
  • [24] Thermal calibration procedure for internal infrared laser deflection apparatus -: art. no. 094905
    Perpiñà, X
    Jordà, X
    Madrid, F
    Flores, D
    Hidalgo, S
    Vellvehi, M
    Mestres, N
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2005, 76 (09):
  • [25] Setting the OTDR for its distance scale calibration - art. no. 60461S
    Castellanos, E
    Bermudez, JC
    Serroukh, I
    Fifth Symposium Optics in Industry, 2006, 6046 : S461 - S461
  • [26] SODAR Calibration for turbulence profiling in TMT site testing. - art. no. 626720
    Travouillon, T.
    Ground-based and Airborne Telescopes, Pts 1 and 2, 2006, 6267 : 26720 - 26720
  • [27] Calibration of contact areas: the influence of corner rounding - art. no. 67303B
    Richter, Jan
    Zerbe, Eva-Maria
    Marschner, Thomas
    PHOTOMASK TECHNOLOGY 2007, PTS 1-3, 2007, 6730 : B7303 - B7303
  • [28] Calibration of AVHRR sensors using the reflectance-based method - art. no. 668407
    Czapla-Myers, Jeffrey S.
    Thome, Kurtis J.
    Leisso, Nathan P.
    ATMOSPHERIC AND ENVIRONMENTAL REMOTE SENSING DATA PROCESSING AND UTILIZATION III: READINESS FOR GEOSS, 2007, 6684 : 68407 - 68407
  • [29] Self-calibration from measurements of targets with known dynamics - art. no. 591312
    Burns, PD
    Blair, WD
    Signal and Data Processing of Small Targets 2005, 2005, 5913 : 91312 - 91312
  • [30] τ→ρππν decays -: art. no. 097302
    Li, BA
    PHYSICAL REVIEW D, 1998, 58 (09)