Optimized use and calibration of autocollimators in deflectometry - art. no. 670407

被引:29
|
作者
Geckeler, Ralf D. [1 ]
Just, Andreas [1 ]
机构
[1] Phys Tech Bundesanstalt Braunschweig & Berlin PTB, D-38116 Braunschweig, Germany
关键词
deflectometry; autocollimator; angle; angle calibration; traceability; flatness standard; precision metrology;
D O I
10.1117/12.732384
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Accurate and traceable angle measurement poses a central challenge to deflectometric profilometry. High-resolution electronic autocollimators are capable of providing accurate angle metrology for this purpose. The optimized calibration and the use of autocollimators under well-defined and stable measurement. conditions are central to their proper application.. To illustrate these issues, the autocollimator in use in the Extended Shear Angle Difference (ESAD) device for the absolute and traceable topography measurement of optical surfaces built at the Physikalisch-Technische Bundesanstalt (PTB) is considered. In contrast to other deflectometric profilers, ESAD combines deflectometric and shearing techniques in a unique way to minimize measurement errors and to optimize measurand traceability. Sub-nanometer repeatability, reproducibility, and uncertainty of the topography measurement are achieved for scans across near-flat surfaces up to 500 mm in diameter. In this paper, the ESAD shearing deflectometer and its measuring capabilities are presented. Information on the optimized use and accurate calibration of autocollimators for deflectometric applications is provided. The calibration of autocollimators by comparison with the highly accurate primary angle standard of PTB is illustrated. Factors influencing their angle response are discussed, such as the position of the aperture stop both along the autocollimator's optical axis and perpendicular to it.
引用
收藏
页码:70407 / 70407
页数:12
相关论文
共 50 条
  • [31] Prethermalization -: art. no. 142002
    Berges, J
    Borsányi, S
    Wetterich, C
    PHYSICAL REVIEW LETTERS, 2004, 93 (14) : 142002 - 1
  • [32] Development of an optical fiber standard for OTDRs distance scale calibration - art. no. 604606
    Bermudez, JC
    Fifth Symposium Optics in Industry, 2006, 6046 : 4606 - 4606
  • [33] Calibration of an eye oximeter with a dynamic eye phantom - art. no. 68700N
    Nabili, A.
    Bardakci, D.
    Helling, K.
    Matyas, C.
    Muro, S.
    Ramella-Roman, J. C.
    DESIGN AND PERFORMANCE VALIDATION OF PHANTOMS USED IN CONJUNCTION WITH OPTICAL MEASUREMENTS OF TISSUE, 2008, 6870 : N8700 - N8700
  • [34] Camera calibration of the Stereo vision measurement system - art. no. 70183N
    Li, Weimin
    Li, Bin
    Li, Xiaofeng
    ADVANCED OPTICAL AND MECHANICAL TECHNOLOGIES IN TELESCOPES AND INSTRUMENTATION, PTS 1-3, 2008, 7018 : N183 - N183
  • [35] Branonium -: art. no. 037
    Burgess, CP
    Martineau, P
    Quevedo, F
    Rabadán, R
    JOURNAL OF HIGH ENERGY PHYSICS, 2003, (06):
  • [36] Everpresent Λ -: art. no. 103523
    Ahmed, M
    Dodelson, S
    Greene, PB
    Sorkin, R
    PHYSICAL REVIEW D, 2004, 69 (10):
  • [37] Evaluation of the surface of objects by use of Minnaert constants - art. no. 674204
    Okayama, Hiroshi
    Li, Cong
    REMOTE SENSING FOR AGRICULTURE, ECOSYSTEMS, AND HYDROLOGY IX, 2007, 6742 : 74204 - 74204
  • [38] Characterization of optical components for use in harsh environments - art. no. 628702
    Bright, Michelle
    Morelli, Gregg
    Optical Technologies for Arming, Safing, Fuzing, and Firing II, 2006, 6287 : 28702 - 28702
  • [39] On the use of sedimentation rates in deciphering global change -: art. no. 1751
    Métivier, F
    GEOPHYSICAL RESEARCH LETTERS, 2002, 29 (15) : 41 - 1
  • [40] The use of biochemical methods in extraterrestrial life detection - art. no. 630905
    McDonald, Gene
    Instruments, Methods, and Missions for Astrobiology IX, 2006, 6309 : 30905 - 30905