Fully automated corneal endothelial morphometry of images captured by clinical specular microscopy

被引:5
|
作者
Bucht, Curry [1 ]
Soderberg, Per [2 ]
Manneberg, Goran [3 ]
机构
[1] Karolinska Inst, St Eriks Eye Hosp, Sect Eye & Vis, Dept Clin Neurosci, Stockholm, Sweden
[2] Uppsala Univ, Dept Ophtalmol & Neurosci, S-75105 Uppsala, Sweden
[3] KTH, Royal Sch Technol, Dept Biomed & Xray Phys, Stockholm, Sweden
来源
OPHTHALMIC TECHNOLOGIES XIX | 2009年 / 7163卷
关键词
cornea; endothelium; Fourier; morphometry; morphology; microscopy; CELL-DENSITY;
D O I
10.1117/12.816850
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
The corneal endothelium serves as the posterior barrier of the cornea. Factors such as clarity and refractive properties of the cornea are in direct relationship to the quality of the endothelium. The endothelial cell density is considered the most important morphological factor. Morphometry of the corneal endothelium is presently done by semi-automated analysis of pictures captured by a Clinical Specular Microscope (CSM). Because of the occasional need of operator involvement, this process can be tedious, having a negative impact on sampling size. This study was dedicated to the development of fully automated analysis of images of the corneal endothelium, captured by CSM, using Fourier analysis. Software was developed in the mathematical programming language Matlab. Pictures of the corneal endothelium, captured by CSM, were read into the analysis software. The software automatically performed digital enhancement of the images. The digitally enhanced images of the corneal endothelium were transformed, using the fast Fourier transform (FFT). Tools were developed and applied for identification and analysis of relevant characteristics of the Fourier transformed images. The data obtained from each Fourier transformed image was used to calculate the mean cell density of its corresponding corneal endothelium. The calculation was based on well known diffraction theory. Results in form of estimated cell density of the corneal endothelium were obtained, using fully automated analysis software on images captured by CSM. The cell density obtained by the fully automated analysis was compared to the cell density obtained from classical, semi-automated analysis and a relatively large correlation was found.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Possible sampling error in donor corneal specular microscopy images: a pilot study
    Naves, Obidulho Sakassegawa
    Reis Carvalho, Fabio Ursulino
    Santos de Almeida, Marco Otavio
    da Silva, Andre Ferreira
    Holzchuh, Ricardo
    Hida, Richard Y.
    Abib, Fernando Cesar
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [42] Simulation of specular microscopy images of corneal endothelium, a tool for control of measurement errors
    Bucht, Curry
    Soderberg, Per
    Manneberg, Goran
    ACTA OPHTHALMOLOGICA, 2011, 89 (03) : e242 - e250
  • [43] Non-contact Specular Microscopy for Evaluation of Corneal Endothelium in Early Fuchs' Endothelial Corneal Dystrophy
    Huang, Jianyan
    Liu, Xuan
    Tepelus, Tudor
    Modak, Cristina
    Chopra, Vikas
    Sadda, Srinivas R.
    Lee, Olivia L.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)
  • [44] RELOCATION OF POSTERIOR CORNEAL RINGS IN CLINICAL WIDE FIELD SPECULAR MICROSCOPY
    REINEHR, DP
    ROBERTSON, IF
    STASIUK, RM
    AUSTRALIAN AND NEW ZEALAND JOURNAL OF OPHTHALMOLOGY, 1985, 13 (04): : 381 - 386
  • [45] Assessing Fuchs Corneal Endothelial Dystrophy Using Artificial Intelligence-Derived Morphometric Parameters From Specular Microscopy Images
    Prada, Angelica M.
    Quintero, Fernando
    Mendoza, Kevin
    Galvis, Virgilio
    Tello, Alejandro
    Romero, Lenny A.
    Marrugo, Andres G.
    CORNEA, 2024, 43 (09) : 1080 - 1087
  • [46] Fully Automated Montaging of Laser Scanning In Vivo Confocal Microscopy Images of the Human Corneal Subbasal Nerve Plexus
    Turuwhenua, Jason T.
    Patel, Dipika V.
    McGhee, Charles N. J.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2012, 53 (04) : 2235 - 2242
  • [47] Possible Sampling Error in Corneal Specular Microscopy: Can Central Endothelial Data Generated by Specular Microscope Represent the Real Clinical Condition of the Whole Cornea?
    van den Berg, Arthur Buffara
    Holzchuh, Ricardo
    Hida, Richard Yudi
    CORNEA, 2020, 39 (06) : 779 - 781
  • [48] Evaluation of corneal endothelial cell morphology by specular microscopy in patients with acute anterior uveitis
    Sevinc, Duygu
    Celik, Tuba
    Ugurbas, Silay Canturk
    Ugurbas, Suat Hayri
    INTERNATIONAL OPHTHALMOLOGY, 2022, 42 (04) : 1339 - 1345
  • [49] RESTRICTION OF THE ENDOTHELIAL IMAGE IN SPECULAR MICROSCOPY BY THE CORNEAL SURFACE REFLEX AND THE STROMAL LIGHT SCATTER
    BIGAR, F
    REME, C
    THAER, A
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1979, : 275 - 275
  • [50] Evaluation of corneal endothelial cell morphology by specular microscopy in patients with acute anterior uveitis
    Duygu Sevinc
    Tuba Celik
    Silay Canturk Ugurbas
    Suat Hayri Ugurbas
    International Ophthalmology, 2022, 42 : 1339 - 1345