Fully automated corneal endothelial morphometry of images captured by clinical specular microscopy

被引:5
|
作者
Bucht, Curry [1 ]
Soderberg, Per [2 ]
Manneberg, Goran [3 ]
机构
[1] Karolinska Inst, St Eriks Eye Hosp, Sect Eye & Vis, Dept Clin Neurosci, Stockholm, Sweden
[2] Uppsala Univ, Dept Ophtalmol & Neurosci, S-75105 Uppsala, Sweden
[3] KTH, Royal Sch Technol, Dept Biomed & Xray Phys, Stockholm, Sweden
来源
OPHTHALMIC TECHNOLOGIES XIX | 2009年 / 7163卷
关键词
cornea; endothelium; Fourier; morphometry; morphology; microscopy; CELL-DENSITY;
D O I
10.1117/12.816850
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
The corneal endothelium serves as the posterior barrier of the cornea. Factors such as clarity and refractive properties of the cornea are in direct relationship to the quality of the endothelium. The endothelial cell density is considered the most important morphological factor. Morphometry of the corneal endothelium is presently done by semi-automated analysis of pictures captured by a Clinical Specular Microscope (CSM). Because of the occasional need of operator involvement, this process can be tedious, having a negative impact on sampling size. This study was dedicated to the development of fully automated analysis of images of the corneal endothelium, captured by CSM, using Fourier analysis. Software was developed in the mathematical programming language Matlab. Pictures of the corneal endothelium, captured by CSM, were read into the analysis software. The software automatically performed digital enhancement of the images. The digitally enhanced images of the corneal endothelium were transformed, using the fast Fourier transform (FFT). Tools were developed and applied for identification and analysis of relevant characteristics of the Fourier transformed images. The data obtained from each Fourier transformed image was used to calculate the mean cell density of its corresponding corneal endothelium. The calculation was based on well known diffraction theory. Results in form of estimated cell density of the corneal endothelium were obtained, using fully automated analysis software on images captured by CSM. The cell density obtained by the fully automated analysis was compared to the cell density obtained from classical, semi-automated analysis and a relatively large correlation was found.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Contact Specular Microscopy Reliably Images the Same Endothelial Location
    Kahan, Elias H.
    Ede, Ezekiel
    Shapiro, Evan R.
    Abizgildin, Dzhalil
    Mandel, Rose
    Blitzer, Andrea L.
    Prescott, Christina R.
    Colby, Kathryn
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2024, 65 (07)
  • [32] A Fully Automated Segmentation and Morphometric Parameter Estimation System for Assessing Corneal Endothelial Cell Images
    Qu, Jing-Hao
    Qin, Xiao-Ran
    Peng, Rong-Mei
    Xiao, Ge-Ge
    Cheng, Jian
    Gu, Shao-Feng
    Wang, Hai-Kun
    Hong, Jing
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2022, 239 : 142 - 153
  • [33] PANORAMIC VIEW OF THE HUMAN CORNEAL ENDOTHELIUM BY WIDE FIELD SPECULAR MICROSCOPY AND TOPOGRAPHICAL MORPHOMETRY OF ENDOTHELIAL CHANGE AFTER CATARACT-EXTRACTION
    OHARA, K
    KANAGAMI, S
    TATSUI, T
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 1982, 26 (01) : 132 - 132
  • [34] Corneal endothelium in xeroderma pigmentosum: clinical specular microscopy study
    Mohamed, Ashik
    Peguda, Rajini
    Ramappa, Muralidhar
    Ali, Mohammad Javed
    Chaurasia, Sunita
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2016, 100 (06) : 750 - 753
  • [35] CLINICAL SPECULAR MICROSCOPY OF POSTERIOR POLYMORPHOUS ENDOTHELIAL DYSTROPHY
    HIRST, LW
    WARING, GO
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1983, 95 (02) : 143 - 155
  • [36] Automated image analysis of the corneal endothelium from contact specular microscopy.
    Stevenson, RWW
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1996, 37 (03) : 386 - 386
  • [37] Corneal endothelial specular microscopy following deep lamellar keratoplasty with lyophilised tissue
    Morris, E
    Kirwan, JF
    Sujatha, S
    Rostron, CK
    EYE, 1998, 12 (4) : 619 - 622
  • [38] Evaluation of corneal endothelial morphology in type 2 diabetes mellitus with specular microscopy
    Songur, Murat Serkan
    Akansel, Murat
    Bayhan, Seray Asian
    Yildirim, Tekin
    Bayhan, Hasan Ali
    ANNALS OF CLINICAL AND ANALYTICAL MEDICINE, 2022, 13 (05): : 544 - 547
  • [39] Corneal endothelial specular microscopy following deep lamellar keratoplasty with lyophilised tissue
    E Morris
    J F Kirwan
    S Sujatha
    C K Rostron
    Eye, 1998, 12 : 619 - 622
  • [40] Corneal endothelial cell density and pachymetry measured by contact and noncontact specular microscopy
    Modis, L
    Langenbucher, A
    Seitz, B
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (10): : 1763 - 1769