Fully automated corneal endothelial morphometry of images captured by clinical specular microscopy

被引:5
|
作者
Bucht, Curry [1 ]
Soderberg, Per [2 ]
Manneberg, Goran [3 ]
机构
[1] Karolinska Inst, St Eriks Eye Hosp, Sect Eye & Vis, Dept Clin Neurosci, Stockholm, Sweden
[2] Uppsala Univ, Dept Ophtalmol & Neurosci, S-75105 Uppsala, Sweden
[3] KTH, Royal Sch Technol, Dept Biomed & Xray Phys, Stockholm, Sweden
来源
OPHTHALMIC TECHNOLOGIES XIX | 2009年 / 7163卷
关键词
cornea; endothelium; Fourier; morphometry; morphology; microscopy; CELL-DENSITY;
D O I
10.1117/12.816850
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
The corneal endothelium serves as the posterior barrier of the cornea. Factors such as clarity and refractive properties of the cornea are in direct relationship to the quality of the endothelium. The endothelial cell density is considered the most important morphological factor. Morphometry of the corneal endothelium is presently done by semi-automated analysis of pictures captured by a Clinical Specular Microscope (CSM). Because of the occasional need of operator involvement, this process can be tedious, having a negative impact on sampling size. This study was dedicated to the development of fully automated analysis of images of the corneal endothelium, captured by CSM, using Fourier analysis. Software was developed in the mathematical programming language Matlab. Pictures of the corneal endothelium, captured by CSM, were read into the analysis software. The software automatically performed digital enhancement of the images. The digitally enhanced images of the corneal endothelium were transformed, using the fast Fourier transform (FFT). Tools were developed and applied for identification and analysis of relevant characteristics of the Fourier transformed images. The data obtained from each Fourier transformed image was used to calculate the mean cell density of its corresponding corneal endothelium. The calculation was based on well known diffraction theory. Results in form of estimated cell density of the corneal endothelium were obtained, using fully automated analysis software on images captured by CSM. The cell density obtained by the fully automated analysis was compared to the cell density obtained from classical, semi-automated analysis and a relatively large correlation was found.
引用
收藏
页数:8
相关论文
共 50 条
  • [11] CLINICAL SPECULAR MICROSCOPY .2. QUALITATIVE EVALUATION OF CORNEAL ENDOTHELIAL PHOTOMICROGRAPHS
    LAING, RA
    SANDSTROM, MM
    LEIBOWITZ, HM
    ARCHIVES OF OPHTHALMOLOGY, 1979, 97 (09) : 1720 - 1725
  • [12] SPECULAR MICROSCOPY OF CORNEAL ENDOTHELIAL-CELLS IN RABBITS
    MORITA, H
    JOURNAL OF VETERINARY MEDICAL SCIENCE, 1995, 57 (02): : 273 - 277
  • [13] SPECULAR MICROSCOPY OF IRIDO-CORNEAL ENDOTHELIAL SYNDROME
    HIRST, LW
    QUIGLEY, HA
    STARK, WJ
    SHIELDS, NB
    AUSTRALIAN JOURNAL OF OPHTHALMOLOGY, 1980, 8 (02): : 139 - 146
  • [14] Comparison of Manual and Automated Grading Methods for Corneal Endothelial Cell Density Measurements by Specular Microscopy
    Modak, Cristina
    Huang, Jianyan
    Maram, Jyotsna
    Marion, Ken
    Obregon, Luisa
    Niemeyer, Moritz
    Sadda, Srinivas R.
    Chopra, Vikas
    Lee, Olivia L.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [15] Comparison of manual & automated analysis methods for corneal endothelial cell density measurements by specular microscopy
    Huang, Jianyan
    Maram, Jyotsna
    Tepelus, Tudor C.
    Modak, Cristina
    Marion, Ken
    Sadda, SriniVas R.
    Chopra, Vikas
    Lee, Olivia L.
    JOURNAL OF OPTOMETRY, 2018, 11 (03) : 182 - 191
  • [16] Specular microscopy of the corneal endothelial cells in common marmosets
    Morita, H
    Shimomura, K
    JOURNAL OF VETERINARY MEDICAL SCIENCE, 1996, 58 (03): : 277 - 279
  • [17] Clinical and Specular microscopy characteristics and corelation in Iridocorneal endothelial syndrome without corneal edema
    Chaurasia, Sunita
    Choudhari, Nikhil S.
    Mohamed, Ashik
    SEMINARS IN OPHTHALMOLOGY, 2021, 36 (07) : 561 - 568
  • [18] Corneal endothelial specular microscopy following deep lamellar keratoplasty
    Morris, E
    Sujatha, S
    Kirwan, JF
    Dalton, R
    Rostron, CK
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1997, 38 (04) : 3989 - 3989
  • [19] REAPPRAISAL OF CORNEAL CRYOPRESERVATION BY SPECULAR MICROSCOPY - INDICATION OF ENDOTHELIAL DAMAGE
    TAYLOR, MJ
    CRYOBIOLOGY, 1979, 16 (06) : 612 - 613
  • [20] SPECULAR MICROSCOPY OF CORNEAL ENDOTHELIAL-CELLS IN CYNOMOLGUS MONKEYS
    MORITA, H
    SHIMOMURA, K
    SAKUMA, Y
    JOURNAL OF VETERINARY MEDICAL SCIENCE, 1994, 56 (04): : 763 - 764