摘要
Determination and understanding the photon beam attenuation by the photon beam modifier and the radiation beam softening for clinical use is more important part of material study for the beam modifier enhancements and the linac improvements. A Monte Carlo model was used to simulate 6 MeV photon beams from a Varian Clinac 2100 accelerator with the flattening filter and the later was replaced by the aluminum slab with variable thickness. The Monte Carlo geometry was validated by a gamma index acceptance rate of 99% in PDD and 98% in dose profiles, the gamma criteria was 3% for dose difference and 3 mm for distance to agreement. The purpose was to investigate aluminum material attenuation and beam softening coefficients as a function of the inserted aluminum slab thickness and of off-axis distance. The attenuation and beam softening coefficients were not identical for the same off-axis distance and they varied as a function of aluminum slab thickness. The results of our study were shown that the beam softening coefficients were varied with thickness beam modifier material used for beam softening and the off-axis distance inside the irradiation field. Thereafter, the softening coefficient a (1) have a maximum of 2.5 x 10(-1) cm(-1) for the aluminum slab thickness of 1 mm, 1.4 x 10(-1) cm(-1) for the aluminum slab thickness of 1.5 mm and 4.47 x 10(-2) cm(-1) for the aluminum slab thickness of 2 mm. The maximum of the second softening coefficient a (2) was 1.02 x 10(-2) cm(-2) for the aluminum slab thickness of 1 mm, was 1.92 x 10(-2) cm(-2) for the aluminum slab thickness of 1.5 mm and was 1.93 x 10(-2) cm(-2) for the aluminum slab thickness of 2 mm. Our study can be a basic investigation of photon beam softening material that will be used in the future linac configuration and also in the photon beam modifiers.
引用
收藏
页码:263 / 270
页数:8
相关论文
共 50 条
  • [21] Analysis of characteristics and validation of 6 MV photon beam produced by Elekta Synergy linear accelerator using EGSnrc Monte Carlo code
    Gundem, Esin
    Dirican, Bahar
    RADIATION PHYSICS AND CHEMISTRY, 2021, 184
  • [22] Photon beam softening coefficient determination with slab thickness in small filed size: Monte Carlo study
    Bencheikh M.
    Maghnouj A.
    Tajmouati J.
    Physics of Particles and Nuclei Letters, 2017, 14 (6) : 963 - 970
  • [23] Photon scatter in portal images: Physical characteristics of pencil beam kernels generated using the EGS Monte Carlo code
    McCurdy, BMC
    Pistorius, S
    MEDICAL PHYSICS, 2000, 27 (02) : 312 - 320
  • [24] Radiation transport calculations for 50 MV photon therapy beam using the Monte Carlo code Geant4
    Larsson, S
    Svensson, R
    Gudowska, I
    Ivanchenko, V
    Brahme, A
    RADIATION PROTECTION DOSIMETRY, 2005, 115 (1-4) : 503 - 507
  • [25] Validation of Monte carlo Geant4 multithreading code for a 6 MV photon beam of varian linac on the grid computing
    Assalmi, Mustapha
    Diaf, El Yamani
    Mansour, Najim
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2020, 25 (06) : 1001 - 1010
  • [26] A Method for Automatic Commissioning of a GPU-Based Monte Carlo Code for Clinica Photon Beam Dose Calculation
    Tian, Z.
    Townson, R.
    Graves, Y.
    Jia, X.
    Jiang, S.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [27] Photon dose calculation of a three-dimensional treatment planning system compared to the Monte Carlo code BEAM
    Francescon, P
    Cavedon, C
    Reccanello, S
    Cora, S
    MEDICAL PHYSICS, 2000, 27 (07) : 1579 - 1587
  • [28] Evaluation of a 50-MV photon therapy beam from a racetrack microtron - Using MCNP4B Monte Carlo code
    Gudowska, I
    Sorcini, B
    Svensson, R
    ADVANCED MONTE CARLO FOR RADIATION PHYSICS, PARTICLE TRANSPORT SIMULATION AND APPLICATIONS, 2001, : 317 - 322
  • [29] A comprehensive study on the photon energy response of RadFET dosimeters using the PENELOPE Monte Carlo code
    Kahraman, A.
    Kaya, S.
    Jaksic, A.
    Yilmaz, E.
    RADIATION EFFECTS AND DEFECTS IN SOLIDS, 2015, 170 (05): : 367 - 376
  • [30] Using electron beam modifiers in the DPM Monte Carlo code for electron beam treatment planning
    Tyagi, N.
    Tien, C.
    Curran, B.
    Fraass, B.
    MEDICAL PHYSICS, 2007, 34 (06) : 2502 - 2503