Photon beam softening coefficient determination with slab thickness in small filed size: Monte Carlo study

被引:9
|
作者
Bencheikh M. [1 ]
Maghnouj A. [1 ]
Tajmouati J. [1 ]
机构
[1] LISTA Laboratory, Physics Department, Faculty of Sciences Dhar El-Mahraz, University of Sidi Mohamed Ben Abdellah, Fez
关键词
BEAMDP code; BEAMnrc code; Monte Carlo simulation; Photon beam softening; Slab thickness;
D O I
10.1134/S1547477117060085
中图分类号
学科分类号
摘要
Determination and understanding of photon beam softening using material soften photon beam for clinical usage is important for material study for attenuation and for beam modifier enhancements and linac improvements. Monte Carlo model was used to simulate 6 MeV photon beams produced by Varian Clinac 2100 accelerator with flattening filter thereafter the flattening filter was replaced by a slab of aluminum and copper with different of 0.5, 1, 1.5 and 2 mm. The Monte Carlo geometry was validated by a gamma index acceptance rate of 99% in PDD and 98% in dose profiles, the gamma criteria was 3% for dose difference and 3mm for distance to agreement. The purpose was to investigate the beam softening for small size and beam attenuation as a function of inserted slab thickness of copper and aluminum and also as a function of off-axis distance. For beam softening evaluation, variation amplitude of beam softening coefficient a1 was very high near the beam central axis and decreased with off-axis distance and also it was high for aluminum slab compared to copper slab. For aluminum slab, variation amplitude of beam softening coefficient a1 have a minimum at–0.5 cm–1 and a maximum at 0.5 cm–1 and for copper slab, variation amplitude of beam softening a1 have a minimum at–0.15 cm–1 and a maximum at 0.11 cm–1. Variation amplitude of beam softening coefficient a2 was very high near the beam central axis and decreased with off-axis distance and it was very high for aluminum slab compared to copper slab. For aluminum slab, variation amplitude of beam softening coefficient a2 have a minimum at–0.54 cm–2 and a maximum at 0.44 cm–2 and for copper slab, variation amplitude of beam softening coefficient a2 have a minimum at–0.111 cm–2 and a maximum at 0.0825 cm–2. © 2017, Pleiades Publishing, Ltd.
引用
收藏
页码:963 / 970
页数:7
相关论文
共 50 条
  • [1] Photon beam softening coefficients evaluation for a 6 MeV photon beam for an aluminum slab: Monte Carlo study using BEAMnrc Code, DOSXYZnrc Code, and BEAMDP code
    Mohamed Bencheikh
    Abdelmajid Maghnouj
    Jaouad Tajmouati
    Moscow University Physics Bulletin, 2017, 72 : 263 - 270
  • [2] Photon Beam Softening Coefficients Evaluation for a 6 MeV Photon Beam for an Aluminum Slab: Monte Carlo Study Using BEAMnrc Code, DOSXYZnrc Code, and BEAMDP Code
    Bencheikh, Mohamed
    Maghnouj, Abdelmajid
    Tajmouati, Jaouad
    MOSCOW UNIVERSITY PHYSICS BULLETIN, 2017, 72 (03) : 263 - 270
  • [3] Determination of the small-field output factor for 6 MV photon beam using EGSnrc Monte Carlo
    Chuah, K. W.
    Aziz, Abdul M. Z.
    Jayamani, J.
    JOURNAL OF MEDICAL PHYSICS, 2022, 47 (03) : 301 - 308
  • [4] Dosimetric variation due to the photon beam energy in the small-animal irradiation: A Monte Carlo study
    Chow, James C. L.
    Leung, Michael K. K.
    Lindsay, Patricia E.
    Jaffray, David A.
    MEDICAL PHYSICS, 2010, 37 (10) : 5322 - 5329
  • [5] Relative Attenuation and Beam Softening Study with Flattening Filter Volume Reduction: Monte Carlo Study
    Mohamed Bencheikh
    Abdelmajid Maghnouj
    Jaouad Tajmouati
    Moscow University Physics Bulletin, 2017, 72 : 647 - 652
  • [6] Relative Attenuation and Beam Softening Study with Flattening Filter Volume Reduction: Monte Carlo Study
    Bencheikh, Mohamed
    Maghnouj, Abdelmajid
    Tajmouati, Jaouad
    MOSCOW UNIVERSITY PHYSICS BULLETIN, 2017, 72 (06) : 647 - 652
  • [7] Output factor determination based on Monte Carlo simulation for small cone field in 10-MV photon beam
    Fukata K.
    Sugimoto S.
    Kurokawa C.
    Saito A.
    Inoue T.
    Sasai K.
    Radiological Physics and Technology, 2018, 11 (2) : 192 - 201
  • [8] Monte Carlo study on electron contamination and output factors of small field dosimetry in 6 MV photon beam
    Yani, Sitti
    Dirgayussa, I. Gde Eka
    Rhani, Mohamad Fahdillah
    Soh, Roger C. X.
    Haryanto, Freddy
    Arif, Idam
    SMART SCIENCE, 2016, 4 (02): : 87 - 94
  • [9] Small fields characterization of teletherapy cobalt-60 photon beam: An experimental and Monte-Carlo study
    Singh A.
    Singh G.
    Saini A.
    Kinhikar R.A.
    Kumar P.
    Measurement: Sensors, 2023, 25
  • [10] A Monte Carlo study of the thickness determination of ultra-thin films
    Tan, ZY
    Xia, YY
    SCANNING, 2002, 24 (05) : 257 - 263