Photon Beam Softening Coefficients Evaluation for a 6 MeV Photon Beam for an Aluminum Slab: Monte Carlo Study Using BEAMnrc Code, DOSXYZnrc Code, and BEAMDP Code

被引:11
|
作者
Bencheikh, Mohamed [1 ]
Maghnouj, Abdelmajid [1 ]
Tajmouati, Jaouad [1 ]
机构
[1] Univ Sidi Mohamed Ben Abdellah, Fac Sci Dhar El Mahraz, Dept Phys, LISTA Lab, Fes, Morocco
关键词
aluminum slab; Monte Carlo simulation; photon beam softening; BEAMnrc code; BEAMDP code; DOSIMETRIC PROPERTIES; ELECTRON-BEAM; DISTRIBUTIONS; ACCELERATOR; SENSITIVITY; SIMULATION; QUALITY; LEAKAGE;
D O I
10.3103/S0027134917030043
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Determination and understanding the photon beam attenuation by the photon beam modifier and the radiation beam softening for clinical use is more important part of material study for the beam modifier enhancements and the linac improvements. A Monte Carlo model was used to simulate 6 MeV photon beams from a Varian Clinac 2100 accelerator with the flattening filter and the later was replaced by the aluminum slab with variable thickness. The Monte Carlo geometry was validated by a gamma index acceptance rate of 99% in PDD and 98% in dose profiles, the gamma criteria was 3% for dose difference and 3 mm for distance to agreement. The purpose was to investigate aluminum material attenuation and beam softening coefficients as a function of the inserted aluminum slab thickness and of off-axis distance. The attenuation and beam softening coefficients were not identical for the same off-axis distance and they varied as a function of aluminum slab thickness. The results of our study were shown that the beam softening coefficients were varied with thickness beam modifier material used for beam softening and the off-axis distance inside the irradiation field. Thereafter, the softening coefficient a (1) have a maximum of 2.5 x 10(-1) cm(-1) for the aluminum slab thickness of 1 mm, 1.4 x 10(-1) cm(-1) for the aluminum slab thickness of 1.5 mm and 4.47 x 10(-2) cm(-1) for the aluminum slab thickness of 2 mm. The maximum of the second softening coefficient a (2) was 1.02 x 10(-2) cm(-2) for the aluminum slab thickness of 1 mm, was 1.92 x 10(-2) cm(-2) for the aluminum slab thickness of 1.5 mm and was 1.93 x 10(-2) cm(-2) for the aluminum slab thickness of 2 mm. Our study can be a basic investigation of photon beam softening material that will be used in the future linac configuration and also in the photon beam modifiers.
引用
收藏
页码:263 / 270
页数:8
相关论文
共 50 条
  • [1] Photon beam softening coefficients evaluation for a 6 MeV photon beam for an aluminum slab: Monte Carlo study using BEAMnrc Code, DOSXYZnrc Code, and BEAMDP code
    Mohamed Bencheikh
    Abdelmajid Maghnouj
    Jaouad Tajmouati
    Moscow University Physics Bulletin, 2017, 72 : 263 - 270
  • [2] Validation of Monte Carlo simulation of 6 MV photon beam produced by Varian Clinac 2100 linear accelerator using BEAMnrc code and DOSXYZnrc code
    Bencheikh M.
    Maghnouj A.
    Tajmouati J.
    Didi A.
    Ezzati A.O.
    Physics of Particles and Nuclei Letters, 2017, 14 (5) : 780 - 787
  • [3] Energetic properties’ investigation of removing flattening filter at phantom surface: Monte Carlo study using BEAMnrc code, DOSXYZnrc code and BEAMDP code
    Bencheikh M.
    Maghnouj A.
    Tajmouati J.
    Physics of Particles and Nuclei Letters, 2017, 14 (6) : 953 - 962
  • [4] Monte Carlo simulation of Varian Linac for 6 MV photon beam with BEAMnrc code
    Mohammed, Maged
    El Bardouni, T.
    Chakir, E.
    Boukhal, H.
    Saeed, M.
    Ahmed, Abdul-Aziz
    RADIATION PHYSICS AND CHEMISTRY, 2018, 144 : 69 - 75
  • [5] Monte Carlo study of a flattening filter-free 6 MV photon beam using the BEAMnrc code.
    Kajaria, Ankit
    Sharma, Neeraj
    Sharma, Shiru
    Pradhan, Satyajit
    Mandal, Abhijit
    Aggarwal M, Lalit
    BIOMEDICAL RESEARCH-INDIA, 2017, 28 (04): : 1566 - 1573
  • [6] Optimization of Efficiency on DOSXYZnrc Monte Carlo Code Parameters for a 12 MV Photon Beam
    Zeghari, Abdelkrim
    Saaidi, Rahal
    El Moursli, Rajaa Cherkaoui
    Kaddouch, Said
    2022 2ND INTERNATIONAL CONFERENCE ON INNOVATIVE RESEARCH IN APPLIED SCIENCE, ENGINEERING AND TECHNOLOGY (IRASET'2022), 2022, : 1033 - 1037
  • [7] Study of the dosimetric properties of an unflattened 6-MV photon beam by using the BEAMnrc code
    Kajaria, Ankit
    Sharma, Neeraj
    Sharma, Shiru
    Pradhan, Satyajit
    Mandal, Abhijit
    Aggarwal, Lalit. M.
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2016, 69 (04) : 657 - 665
  • [8] Study of the dosimetric properties of an unflattened 6-MV photon beam by using the BEAMnrc code
    Ankit Kajaria
    Neeraj Sharma
    Shiru Sharma
    Satyajit Pradhan
    Abhijit Mandal
    Lalit. M. Aggarwal
    Journal of the Korean Physical Society, 2016, 69 : 657 - 665
  • [9] Monte Carlo calculation of nine megavoltage photon beam spectra using the BEAM code
    Sheikh-Bagheri, D
    Rogers, DWO
    MEDICAL PHYSICS, 2002, 29 (03) : 391 - 402
  • [10] Monte Carlo Simulation-Based BEAMnrc Code of a 6 MV Photon Beam Produced by a Linear Accelerator (LINAC)
    Sapundani, R.
    Ekawati, R.
    Wibowo, K. M.
    ATOM INDONESIA, 2021, 47 (03) : 199 - 204