Photon Beam Softening Coefficients Evaluation for a 6 MeV Photon Beam for an Aluminum Slab: Monte Carlo Study Using BEAMnrc Code, DOSXYZnrc Code, and BEAMDP Code

被引:11
|
作者
Bencheikh, Mohamed [1 ]
Maghnouj, Abdelmajid [1 ]
Tajmouati, Jaouad [1 ]
机构
[1] Univ Sidi Mohamed Ben Abdellah, Fac Sci Dhar El Mahraz, Dept Phys, LISTA Lab, Fes, Morocco
关键词
aluminum slab; Monte Carlo simulation; photon beam softening; BEAMnrc code; BEAMDP code; DOSIMETRIC PROPERTIES; ELECTRON-BEAM; DISTRIBUTIONS; ACCELERATOR; SENSITIVITY; SIMULATION; QUALITY; LEAKAGE;
D O I
10.3103/S0027134917030043
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Determination and understanding the photon beam attenuation by the photon beam modifier and the radiation beam softening for clinical use is more important part of material study for the beam modifier enhancements and the linac improvements. A Monte Carlo model was used to simulate 6 MeV photon beams from a Varian Clinac 2100 accelerator with the flattening filter and the later was replaced by the aluminum slab with variable thickness. The Monte Carlo geometry was validated by a gamma index acceptance rate of 99% in PDD and 98% in dose profiles, the gamma criteria was 3% for dose difference and 3 mm for distance to agreement. The purpose was to investigate aluminum material attenuation and beam softening coefficients as a function of the inserted aluminum slab thickness and of off-axis distance. The attenuation and beam softening coefficients were not identical for the same off-axis distance and they varied as a function of aluminum slab thickness. The results of our study were shown that the beam softening coefficients were varied with thickness beam modifier material used for beam softening and the off-axis distance inside the irradiation field. Thereafter, the softening coefficient a (1) have a maximum of 2.5 x 10(-1) cm(-1) for the aluminum slab thickness of 1 mm, 1.4 x 10(-1) cm(-1) for the aluminum slab thickness of 1.5 mm and 4.47 x 10(-2) cm(-1) for the aluminum slab thickness of 2 mm. The maximum of the second softening coefficient a (2) was 1.02 x 10(-2) cm(-2) for the aluminum slab thickness of 1 mm, was 1.92 x 10(-2) cm(-2) for the aluminum slab thickness of 1.5 mm and was 1.93 x 10(-2) cm(-2) for the aluminum slab thickness of 2 mm. Our study can be a basic investigation of photon beam softening material that will be used in the future linac configuration and also in the photon beam modifiers.
引用
收藏
页码:263 / 270
页数:8
相关论文
共 50 条
  • [41] Comparison of Flattening Filter (FF) and Flattening-Filter-Free (FFF) 6 MV photon beam characteristics for small field dosimetry using EGSnrc Monte Carlo code
    Sangeetha, S.
    Sureka, C. S.
    RADIATION PHYSICS AND CHEMISTRY, 2017, 135 : 63 - 75
  • [42] Monte Carlo calculation of photon specific absorbed fractions in digimouse voxelized phantom using InterDosi code
    El Bakkali, Jaafar
    Doudouh, Abderrahmin
    El Bardouni, Tarek
    Sahel, Omar Ait
    RADIATION PHYSICS AND CHEMISTRY, 2021, 182
  • [43] Monte Carlo simulation of MOSFET detectors for high-energy photon beams using the PENELOPE code
    Panettieri, Vanessa
    Duch, Maria Amor
    Jornet, Nuria
    Ginjaume, Merce
    Carrasco, Pablo
    Badal, Andreu
    Ortega, Xavier
    Ribas, Montserrat
    PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (01): : 303 - 316
  • [44] GENERATION OF PHOTON DOSE SPREAD ARRAYS USING THE EGS4 MONTE-CARLO CODE
    MACKIE, TR
    BLAIR, A
    BIELAJEW, AF
    ROGERS, DWO
    BATTISTA, JJ
    MEDICAL PHYSICS, 1985, 12 (04) : 515 - 515
  • [45] THE DEVELOPMENT OF A MONTE-CARLO CODE SIMULATING ELECTRON PHOTON SHOWERS AND ITS EVALUATION BY VARIOUS TRANSPORT BENCHMARKS
    UEHARA, S
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1986, 14 (4-6): : 559 - 570
  • [46] Monte Carlo study of the influence of a novel transmission detector on 6 MV photon beam
    Asuni, G.
    McCurdy, B.
    Jensen, M.
    MEDICAL PHYSICS, 2009, 36 (09) : 4309 - 4309
  • [47] Simulation of the DIII-D Beam Ion Heating Experiment Using A Monte-Carlo Particle Code Combined With a Full Wave Code
    Choi, M.
    Chan, V. S.
    Green, D.
    Heidbrink, W. W.
    Jaeger, E. F.
    Berry, L. A.
    RADIO FREQUENCY POWER IN PLASMAS, 2009, 1187 : 577 - +
  • [48] EVALUATION THE EFFECT OF MAGNETIC FIELD ON CO-60 BEAM USING GEANT4 MONTE CARLO CODE
    Lee, C. I.
    Suh, T. S.
    Choe, B. Y.
    Jeong, W. G.
    Shin, J. W.
    Hong, S. W.
    Park, S. W.
    Ji, Y. H.
    Jung, J. Y.
    Jeong, S. M.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S324 - S324
  • [49] Evaluation of underdosage in the external photon beam radiotherapy of glottic carcinoma: Monte Carlo study
    Spirydovich, S
    Papiez, L
    Moskvin, V
    Desrosiers, P
    RADIOTHERAPY AND ONCOLOGY, 2006, 78 (02) : 159 - 164
  • [50] Using Monte Carlo simulations to commission photon beam output factors - A feasibility study
    Ding, GX
    MEDICAL PHYSICS, 2003, 30 (07) : 1942 - 1942