Patient-specific instrumentation versus conventional instrumentation in total knee arthroplasty

被引:11
|
作者
Chan, Warwick Chun-Wang [1 ]
Pinder, Elizabeth [1 ]
Loeffler, Mark [1 ]
机构
[1] Colchester Hosp Univ NHS Fdn Trust, Dept Trauma & Orthopaed, Colchester, Essex, England
关键词
arthroplasty; replacement; knee; instrumentation; learning curve; COMPUTER-ASSISTED NAVIGATION; MECHANICAL AXIS ALIGNMENT; CORONAL ALIGNMENT; BLOOD-LOSS; FOLLOW-UP; REPLACEMENT; SURVIVAL; SURGERY; GUIDES; METAANALYSIS;
D O I
10.1177/1602400211
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose. To compare patient-specific instrumentation (PSI) with conventional instrumentation in total knee arthroplasty (TKA) in terms of component alignment, operating time, and the learning curve required in a non-teaching hospital. Methods. Records of 33 men and 29 women aged 50 to 88 (mean, 71) years who underwent TKA for osteoarthritis using PSI (n=31) or conventional instrumentation (n=31) by a single surgeon were reviewed. The choice of instrumentation was made by the patient; the surgeon did not express any preference and had not used PSI before. All patients used the same cemented, cruciate-retaining system. Results. The PSI and conventional instrumentation groups were comparable in terms of age, body mass index (BMI), American Society of Anesthesiologists grade, pre- and post-operative haemoglobin level, and the need for blood transfusion. Compared with conventional instrumentation, PSI resulted in a smaller coronal femoral component angle (7.7 degrees vs. 6.4 degrees, p=0.003) and posterior tibial slope angle (6.4 degrees vs. 3.2 degrees, p=0.0001), and smaller variance of the respective angles (p=0.006 and p=0.003). In patients with a BMI >= 30, PSI still resulted in a smaller posterior tibial slope angle (5.8 degrees vs. 3.1 degrees, p=0.015) and variance of the angle (p=0.02). The mean tourniquet time was shorter in the PSI group in all patients (p=0.013) and in patients with BMI kg/m(2) (p=0.0008), and its variance was also smaller in the PSI group (p=0.0004). There was no learning curve required. Conclusion. PSI was simple to use, with no learning curve required. It can be used in non-teaching hospitals and in patients with a high BMI and in cases where the use of an intramedullary alignment guide would be problematic due to previous femoral trauma.
引用
收藏
页码:175 / 178
页数:4
相关论文
共 50 条
  • [31] Mid-term functional outcomes of patient-specific versus conventional instrumentation total knee arthroplasty: a prospective study
    Vikaesh Moorthy
    Jerry Yongqiang Chen
    Ming Han Lincoln Liow
    Pak Lin Chin
    Shi-Lu Chia
    Ngai Nung Lo
    Seng Jin Yeo
    Archives of Orthopaedic and Trauma Surgery, 2021, 141 : 669 - 674
  • [32] The efficacy and safety of patient-specific instrumentation versus conventional instrumentation for unicompartmental knee arthroplasty: Evidence from a meta-analysis
    Wang, Huihui
    Zhang, Liang
    Teng, Xueren
    MEDICINE, 2024, 103 (03) : E36484
  • [33] Comparison of Clinical, Functional, and Radiological Outcomes of Total Knee Arthroplasty Using Conventional and Patient-Specific Instrumentation
    Mehdipour, Soheil
    Qoreishi, Mohamad
    Keipourfard, Ali
    ARCHIVES OF BONE AND JOINT SURGERY-ABJS, 2020, 8 (05): : 625 - 632
  • [34] Preoperative corrections are required for planning of patient-specific instrumentation in total knee arthroplasty
    Okada, Yohei
    Teramoto, Atsushi
    Suzuki, Tomoyuki
    Kii, Yuichiro
    Watanabe, Kota
    Yamashita, Toshihiko
    KNEE, 2017, 24 (06): : 1492 - 1497
  • [35] Patient-Specific Instrumentation Affects Perioperative Blood Loss in Total Knee Arthroplasty
    Cucchi, Davide
    Menon, Alessandra
    Zanini, Beatrice
    Compagnoni, Riccardo
    Ferrua, Paolo
    Randelli, Pietro
    JOURNAL OF KNEE SURGERY, 2019, 32 (06) : 483 - 489
  • [36] Patient-Specific Instrumentation in Total Knee Arthroplasty Provides No Improvement in Component Alignment
    Stronach, Benjamin M.
    Pelt, Christopher E.
    Erickson, Jill A.
    Peters, Christopher L.
    JOURNAL OF ARTHROPLASTY, 2014, 29 (09): : 1705 - 1708
  • [37] Reducing Blood Loss in Bilateral Total Knee Arthroplasty with Patient-Specific Instrumentation
    Rathod, Parthiv A.
    Deshmukh, Ajit J.
    Cushner, Fred D.
    ORTHOPEDIC CLINICS OF NORTH AMERICA, 2015, 46 (03) : 343 - +
  • [38] Systematic Review of Patient-specific Instrumentation in Total Knee Arthroplasty: New but Not Improved
    Sassoon, Adam
    Nam, Denis
    Nunley, Ryan
    Barrack, Robert
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2015, 473 (01) : 151 - 158
  • [39] Accuracy of a Patient-Specific Total Ankle Arthroplasty Instrumentation
    April, Pierre-Marc
    Locke, Eric
    Champagne, Philippe-Hugo
    Angers, Magalie
    Martinez-Gomez, Adriana Patricia
    Seidel, Angela
    Jibri, Zaid
    Lalonde, Karl-Andre
    Meulenkamp, Brad
    FOOT & ANKLE INTERNATIONAL, 2023, 44 (11) : 1150 - 1157
  • [40] Reliability of patient specific instrumentation in total knee arthroplasty
    Jennart, Harold
    Yamben, Marie-Ange Ngo
    Kyriakidis, Theofylaktos
    Zorman, David