Patient-specific instrumentation versus conventional instrumentation in total knee arthroplasty

被引:11
|
作者
Chan, Warwick Chun-Wang [1 ]
Pinder, Elizabeth [1 ]
Loeffler, Mark [1 ]
机构
[1] Colchester Hosp Univ NHS Fdn Trust, Dept Trauma & Orthopaed, Colchester, Essex, England
关键词
arthroplasty; replacement; knee; instrumentation; learning curve; COMPUTER-ASSISTED NAVIGATION; MECHANICAL AXIS ALIGNMENT; CORONAL ALIGNMENT; BLOOD-LOSS; FOLLOW-UP; REPLACEMENT; SURVIVAL; SURGERY; GUIDES; METAANALYSIS;
D O I
10.1177/1602400211
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose. To compare patient-specific instrumentation (PSI) with conventional instrumentation in total knee arthroplasty (TKA) in terms of component alignment, operating time, and the learning curve required in a non-teaching hospital. Methods. Records of 33 men and 29 women aged 50 to 88 (mean, 71) years who underwent TKA for osteoarthritis using PSI (n=31) or conventional instrumentation (n=31) by a single surgeon were reviewed. The choice of instrumentation was made by the patient; the surgeon did not express any preference and had not used PSI before. All patients used the same cemented, cruciate-retaining system. Results. The PSI and conventional instrumentation groups were comparable in terms of age, body mass index (BMI), American Society of Anesthesiologists grade, pre- and post-operative haemoglobin level, and the need for blood transfusion. Compared with conventional instrumentation, PSI resulted in a smaller coronal femoral component angle (7.7 degrees vs. 6.4 degrees, p=0.003) and posterior tibial slope angle (6.4 degrees vs. 3.2 degrees, p=0.0001), and smaller variance of the respective angles (p=0.006 and p=0.003). In patients with a BMI >= 30, PSI still resulted in a smaller posterior tibial slope angle (5.8 degrees vs. 3.1 degrees, p=0.015) and variance of the angle (p=0.02). The mean tourniquet time was shorter in the PSI group in all patients (p=0.013) and in patients with BMI kg/m(2) (p=0.0008), and its variance was also smaller in the PSI group (p=0.0004). There was no learning curve required. Conclusion. PSI was simple to use, with no learning curve required. It can be used in non-teaching hospitals and in patients with a high BMI and in cases where the use of an intramedullary alignment guide would be problematic due to previous femoral trauma.
引用
收藏
页码:175 / 178
页数:4
相关论文
共 50 条
  • [41] Total knee arthroplasty using patient-specific instrumentation for osteoarthritis of the knee: a meta-analysis
    Kizaki, Kazuha
    Shanmugaraj, Ajaykumar
    Yamashita, Fumiharu
    Simunovic, Nicole
    Duong, Andrew
    Khanna, Vickas
    Ayeni, Olufemi R.
    BMC MUSCULOSKELETAL DISORDERS, 2019, 20 (01)
  • [42] Total knee arthroplasty using patient-specific instrumentation for osteoarthritis of the knee: a meta-analysis
    Kazuha Kizaki
    Ajaykumar Shanmugaraj
    Fumiharu Yamashita
    Nicole Simunovic
    Andrew Duong
    Vickas Khanna
    Olufemi R. Ayeni
    BMC Musculoskeletal Disorders, 20
  • [43] Comparison of clinical outcomes of VISIONAIRE patient-specific instrumentation with conventional instrumentation in total knee arthroplasty: a systematic literature review and meta-analysis
    Carsten O. Tibesku
    Steven B. Haas
    Christopher Saunders
    David A. Harwood
    Archives of Orthopaedic and Trauma Surgery, 2023, 143 : 4379 - 4393
  • [44] Comparison of clinical outcomes of VISIONAIRE patient-specific instrumentation with conventional instrumentation in total knee arthroplasty: a systematic literature review and meta-analysis
    Tibesku, Carsten O. O.
    Haas, Steven B. B.
    Saunders, Christopher
    Harwood, David A. A.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2023, 143 (07) : 4379 - 4393
  • [45] Patient-Specific CT-Based Instrumentation versus Conventional Instrumentation in Total Knee Arthroplasty: A Prospective Randomized Controlled Study on Clinical Outcomes and In-Hospital Data
    Kotela, Andrzej
    Lorkowski, Jacek
    Kucharzewski, Marek
    Wilk-Franczuk, Magdalena
    Sliwinski, Zbigniew
    Franczuk, Boguslaw
    Legosz, Pawel
    Kotela, Ireneusz
    BIOMED RESEARCH INTERNATIONAL, 2015, 2015
  • [46] Functional Outcome and Quality of Life after Patient-Specific Instrumentation in Total Knee Arthroplasty
    Chen, Jerry Yonggiang
    Chin, Pak Lin
    Tay, Darren Keng Jin
    Chia, Shi-Lu
    Lo, Ngai Nung
    Yeo, Seng Jin
    JOURNAL OF ARTHROPLASTY, 2015, 30 (10): : 1724 - 1728
  • [47] Patient-specific instrumentation for total knee arthroplasty: Evaluation with computer-tomography tools
    Nabavi, Arash
    Olwill, Caroline M.
    Do, Mike
    Wanasawage, Tanya
    Harris, Ian A.
    JOURNAL OF ORTHOPAEDIC SURGERY, 2017, 25 (01)
  • [48] Outcomes following total knee arthroplasty with CT-based patient-specific instrumentation
    Zhu, Meng
    Chen, Jerry Yongqiang
    Chong, Hwei Chi
    Yew, Andy Khye Soon
    Foo, Leon Siang Shen
    Chia, Shi-Lu
    Lo, Ngai Nung
    Yeo, Seng Jin
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2017, 25 (08) : 2567 - 2572
  • [49] Outcomes following total knee arthroplasty with CT-based patient-specific instrumentation
    Meng Zhu
    Jerry Yongqiang Chen
    Hwei Chi Chong
    Andy Khye Soon Yew
    Leon Siang Shen Foo
    Shi-Lu Chia
    Ngai Nung Lo
    Seng Jin Yeo
    Knee Surgery, Sports Traumatology, Arthroscopy, 2017, 25 : 2567 - 2572
  • [50] Functional Outcome and Quality of Life After Patient-Specific Instrumentation in Total Knee Arthroplasty
    Prakash, Jatin
    JOURNAL OF ARTHROPLASTY, 2016, 31 (04): : 923 - 924