Technetium-99m-DMSA renal cortical scintigraphy to detect experimental acute pyelonephritis in piglets: Comparison of planar (pinhole) and SPECT imaging

被引:0
|
作者
Majd, M
Rushton, HG
Chandra, R
Andrich, MP
Tardif, CP
Rashti, F
机构
[1] CHILDRENS NATL MED CTR,DEPT RADIOL NUCL MED,WASHINGTON,DC 20010
[2] CHILDRENS NATL MED CTR,DEPT UROL,WASHINGTON,DC 20010
[3] CHILDRENS NATL MED CTR,DEPT PATHOL,WASHINGTON,DC 20010
[4] GEORGE WASHINGTON UNIV,WASHINGTON,DC
关键词
pyelonephritis; technetium-99m-DMSA; SPECT; pinhole magnification;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this study was to directly compare the sensitivity and specificity of SPECT and pinhole imaging for the detection of acute pyelonephritis using histology as the standard of reference. Methods: Bilateral vesicoureteral reflux of infected urine was induced in 16 piglets (32 kidneys) by unroofing the intravesical ureter and subsequently instilling a broth culture of E. coli into the bladder, DMSA scans were obtained by both pinhole and SPECT techniques at 24 hr (4 piglets), 48 hr (5 piglets), 72 hr (4 piglets) and 10 days (3 piglets) after instillation of bacteria into the bladder. Kidneys were harvested immediately after scintigraphy for histopathologic examination. Results of the SPECT images, pinhole images and histologic findings were interpreted independently in a blinded fashion. The images of each kidney were classified as positive or negative for pyelonephritis regardless of the severity and number of lesions. To evaluate accuracy of SPECT and pinhole imaging for the detection of individual lesions, each kidney was arbitrarily divided into three zones (upper, middle and lower). Image findings were then compared with the pathology results for the presence or absence of pyelonephritis in each zone. Results: Histopathology revealed pyelonephritis in 24 of 32 kidneys (58 of 96 zones). The sensitivity of the DMSA scan for detection of affected kidneys was 92% for SPECT and 83% for pinhole; overall accuracy was 88% for both. The sensitivity of SPECT for the detection of affected renal zones was slightly better than pinhole imaging (91% compared with 86%), but its specificity was lower (82% compared with 95%) resulting in a similar accuracy. Excluding four piglets where scans were obtained within 24 hr after instillation of bacteria into the bladder, the sensitivity of SPECT and pinhole for the detection of affected kidneys were 95% and 90%, respectively. Their overall accuracy were 96% and 92%. In this subgroup, the sensitivity, specificity and accuracy of SPECT for the detection of involved zones were 96%, 95% and 96%, respectively. The corresponding values for pinhole imaging were 90%, 95% and 92%, respectively. Conclusion: Although the sensitivity of SPECT for the detection of acute pyelonephritis is slightly better than pinhole DMSA scan, the overall accuracy of these two imaging techniques is essentially the same.
引用
收藏
页码:1731 / 1734
页数:4
相关论文
共 50 条
  • [31] The evaluation of acute pyelonephritis and renal scarring with technetium 99m-dimercaptosuccinic acid renal scintigraphy: Evolving concepts and future directions
    Rushton, HG
    PEDIATRIC NEPHROLOGY, 1997, 11 (01) : 108 - 120
  • [32] The evaluation of acute pyelonephritis and renal scarring with technetium 99m-dimercaptosuccinic acid renal scintigraphy: evolving concepts and future directions
    H. Gil Rushton
    Pediatric Nephrology, 1997, 11 : 108 - 120
  • [33] Potential usefulness of SPECT/CT in distinguishing scar from acute pyelonephritis (AP) in renal cortical DMSA imaging: Preliminary data
    Heiba, Sherif
    Stock, Jeffrey
    Khan, Shahid
    Kostakoglu, Lale
    Savitch, Ina
    Machac, Josef
    JOURNAL OF NUCLEAR MEDICINE, 2009, 50
  • [34] Acute pyelonephritis:: Comparison of diagnosis with 99mTc-DMSA SPECT, spiral CT, MR imaging, and power Doppler US in an experimental pig model
    Majd, M
    Blask, ARN
    Markle, BM
    Shalaby-Rana, E
    Pohl, HG
    Park, JS
    Chandra, R
    Rais-Bahrami, K
    Pandya, N
    Patel, KM
    Rushton, HG
    RADIOLOGY, 2001, 218 (01) : 101 - 108
  • [35] Incidence of renal scarring on technetium-99 m dimercaptosuccinic acid renal scintigraphy after acute pyelonephritis, acute focal bacterial nephritis, and renal abscess
    Hosokawa, Takahiro
    Uchiyama, Mayuki
    Tanami, Yutaka
    Sato, Yumiko
    Wakabayashi, Yasuharu
    Oguma, Eiji
    ANNALS OF NUCLEAR MEDICINE, 2023, 37 (03) : 176 - 188
  • [36] Incidence of renal scarring on technetium-99 m dimercaptosuccinic acid renal scintigraphy after acute pyelonephritis, acute focal bacterial nephritis, and renal abscess
    Takahiro Hosokawa
    Mayuki Uchiyama
    Yutaka Tanami
    Yumiko Sato
    Yasuharu Wakabayashi
    Eiji Oguma
    Annals of Nuclear Medicine, 2023, 37 : 176 - 188
  • [37] Results of a five-year study of Tc-99m-DMSA renal scintigraphy in children and adolescents following acute pyelonephritis
    Chroustova, Daniela
    Palyzova, Daniela
    Urbanova, Irena
    Kolska, Monika
    NUCLEAR MEDICINE REVIEW, 2006, 9 (01) : 46 - 50
  • [38] Technetium-99m-sestamibi scintimammography for the detection of breast carcinoma:: Comparison between planar and SPECT imaging
    Tiling, R
    Tatsch, K
    Sommer, H
    Meyer, G
    Pechmann, M
    Gebauer, K
    Münzing, W
    Linke, R
    Khalkhali, I
    Hahn, K
    JOURNAL OF NUCLEAR MEDICINE, 1998, 39 (05) : 849 - 856
  • [39] TC-99M DMSA SPECT IMAGING IN PATIENTS WITH ACUTE SYMPTOMS OR HISTORY OF UTI - COMPARISON WITH ULTRASONOGRAPHY
    MASTIN, ST
    DRANE, WE
    IRAVANI, A
    CLINICAL NUCLEAR MEDICINE, 1995, 20 (05) : 407 - 412
  • [40] Tc-99m DMSA scintigraphy in acute pyelonephritis: comparison results with clinical data, procalcitonin and C-reactive protein tests
    Aydin, F
    Gungor, F
    Kazdal, H
    Boz, A
    Yildiz, A
    Koyun, M
    Baysal, YE
    Akman, S
    Guven, AG
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2004, 31 : S416 - S416