Acute pyelonephritis:: Comparison of diagnosis with 99mTc-DMSA SPECT, spiral CT, MR imaging, and power Doppler US in an experimental pig model

被引:130
|
作者
Majd, M
Blask, ARN
Markle, BM
Shalaby-Rana, E
Pohl, HG
Park, JS
Chandra, R
Rais-Bahrami, K
Pandya, N
Patel, KM
Rushton, HG
机构
[1] Childrens Natl Med Ctr, Dept Radiol, Washington, DC 20010 USA
[2] Childrens Natl Med Ctr, Dept Urol, Washington, DC 20010 USA
[3] Childrens Natl Med Ctr, Dept Pathol, Washington, DC 20010 USA
[4] Childrens Natl Med Ctr, Dept Neonatol, Washington, DC 20010 USA
[5] Childrens Natl Med Ctr, Res Inst, Washington, DC 20010 USA
[6] George Washington Univ, Sch Med, Washington, DC 20010 USA
关键词
animals; kidney; CT; MR; SPECT; US; nephritis; ultrasound; (US); comparative studies;
D O I
10.1148/radiology.218.1.r01ja37101
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To compare the sensitivity and specificity of technetium-99m dimercaptosuccinic acid (DMSA) single photon emission computed tomography (SPECT), spiral computed tomography (CT), magnetic resonance (MR) imaging, and power Doppler ultrasonography (US) for the detection and localization of acute pyelonephritis by using histopathologic findings as the standard of reference. MATERIALSAND METHODS: Brlateral vesicoureteric reflux was surgically created in 35 piglets (70 kidneys). One week later, a liquid bacterial culture of Escherichia coli was injected into the bladder. Three days after induction of urinary infection, imaging studies were performed, and the kidneys were removed for histopathologic examination. SPECT images were obtained 2-3 hours after injection of Tc-99m-DMSA. Transverse and coronal MR images were obtained with gadolinium-enhanced fast inversion recovery. Transverse CT images were obtained before and after injection of contrast agent. Power Doppler US was performed in longitudinal, transverse, and coronal planes. Each kidney was divided into three zones for correlation of findings. RESULTS: Histopathologic examination revealed pyelonephritis in 102 zones in 38 kidneys. Sensitivity and specificity for detecting pyelonephritis in the kidneys were 92.1% and 93.8% for SPECT, 89.5% and 87.5% for MR imaging 86.8% and 87.5% for CT, and 74.3% and 56.7% for US. Sensitivity and specificity for detecting pyelonephritis in the zones were 94.1% and 95.4% for SPECT, 91.2% and 92.6% for MR imaging, 88.2% and 95.5% for CT, and 56.6% and 81.4% for US. The pairwise comparison of these modalities showed no statistically significant difference among them except for US. CONCLUSION: Tc-99m-DMSA SPECT, spiral CT, and MR imaging appear to be equally sensitive and reliable for the detection of acute pyelonephritis; power Doppler US is significantly less accurate.
引用
收藏
页码:101 / 108
页数:8
相关论文
共 27 条
  • [1] DIAGNOSING ACUTE PYELONEPHRITIS WITH CT, 99MTC-DMSA SPECT, AND DOPPLER ULTRASOUND: A COMPARATIVE STUDY
    Han, Chang-Hee
    Lee, Yong Seok
    Cho, Yong-Hyun
    INTERNATIONAL JOURNAL OF UROLOGY, 2014, 21 : A155 - A155
  • [2] Diagnosis of experimental acute pyelonephritis in piglets: Comparison of 99m-Tc-DMSA SPECT, spiral CT, MRI, and power Doppler sonography
    Majd, M
    ShalabyRana, E
    Blask, A
    Markle, BM
    Pohl, H
    Park, J
    RADIOLOGY, 1997, 205 : 880 - 880
  • [3] ACCURACY OF 99MTC-DMSA RENAL SCINTIGRAPHY IN THE DIAGNOSIS OF EXPERIMENTAL ACUTE PYELONEPHRITIS IN PIGLETS
    MAJD, M
    RUSHTON, HG
    CHANDRA, R
    YIM, D
    PEDIATRIC RADIOLOGY, 1988, 18 (03) : 260 - 260
  • [4] CT and 99mTc-DMSA scintigraphy in adult acute pyelonephritis:: A comparative study
    Sattari, A
    Kampouridis, S
    Damry, N
    Hainaux, B
    Ham, HR
    Vandewalle, JC
    Mols, P
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2000, 24 (04) : 600 - 604
  • [5] Comparison of 99mTc-DMSA, 99mTc-MAG3 and ultrasound in detection acute pyelonephritis
    Sahin, A
    Yildirim, M
    Uslu, H
    Akyazi, H
    Ak, C
    Varoglu, E
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 2001, 28 (08): : 1104 - 1104
  • [6] 99mTc-DMSA renal cortical scanning: a comparison of planar, SPECT, and SPECT/CT imaging for the detection of renal cortical scarring
    Mohamadien, Nsreen R. A.
    Mohamed, Marwa S.
    Mekkaway, Mohamed A.
    Ali, Wageeh A.
    Diab, Waleed A.
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2023, 54 (01):
  • [7] 99mTc-DMSA renal cortical scanning: a comparison of planar, SPECT, and SPECT/CT imaging for the detection of renal cortical scarring
    Nsreen R. A. Mohamadien
    Marwa S. Mohamed
    Mohamed A. Mekkaway
    Wageeh A. Ali
    Waleed A. Diab
    Egyptian Journal of Radiology and Nuclear Medicine, 54
  • [8] Doppler US in the diagnosis of acute pyelonephritis:: Comparison with Tc-99m DMSA scintigraphy
    Kaya, GÇ
    Göktay, Y
    Aydin, A
    Seçil, M
    Taskiran, IY
    Bak, M
    Durak, H
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 2001, 28 (08): : 1156 - 1156
  • [9] Extrarenal Uptake of 99mTc-DMSA in Uterine Leiomyoma From Misdiagnosis to Clarity With SPECT/CT Imaging
    Samadi, Mohammad Hadi
    Sahafi, Pegah
    Elahifard, Haniye
    Memar, Bahram
    Barashki, Somaye
    CLINICAL NUCLEAR MEDICINE, 2025, 50 (05) : e317 - e319
  • [10] Added-value of 99mTc-DMSA SPECT/CT to planar imaging in detecting renal cortical defects
    Mohamadien, Nsreen R. A.
    Mohamed, Marwa
    Mekkawy, Mohamed
    Diab, Waleed
    JOURNAL OF NUCLEAR MEDICINE, 2022, 63