Acute pyelonephritis:: Comparison of diagnosis with 99mTc-DMSA SPECT, spiral CT, MR imaging, and power Doppler US in an experimental pig model

被引:130
|
作者
Majd, M
Blask, ARN
Markle, BM
Shalaby-Rana, E
Pohl, HG
Park, JS
Chandra, R
Rais-Bahrami, K
Pandya, N
Patel, KM
Rushton, HG
机构
[1] Childrens Natl Med Ctr, Dept Radiol, Washington, DC 20010 USA
[2] Childrens Natl Med Ctr, Dept Urol, Washington, DC 20010 USA
[3] Childrens Natl Med Ctr, Dept Pathol, Washington, DC 20010 USA
[4] Childrens Natl Med Ctr, Dept Neonatol, Washington, DC 20010 USA
[5] Childrens Natl Med Ctr, Res Inst, Washington, DC 20010 USA
[6] George Washington Univ, Sch Med, Washington, DC 20010 USA
关键词
animals; kidney; CT; MR; SPECT; US; nephritis; ultrasound; (US); comparative studies;
D O I
10.1148/radiology.218.1.r01ja37101
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To compare the sensitivity and specificity of technetium-99m dimercaptosuccinic acid (DMSA) single photon emission computed tomography (SPECT), spiral computed tomography (CT), magnetic resonance (MR) imaging, and power Doppler ultrasonography (US) for the detection and localization of acute pyelonephritis by using histopathologic findings as the standard of reference. MATERIALSAND METHODS: Brlateral vesicoureteric reflux was surgically created in 35 piglets (70 kidneys). One week later, a liquid bacterial culture of Escherichia coli was injected into the bladder. Three days after induction of urinary infection, imaging studies were performed, and the kidneys were removed for histopathologic examination. SPECT images were obtained 2-3 hours after injection of Tc-99m-DMSA. Transverse and coronal MR images were obtained with gadolinium-enhanced fast inversion recovery. Transverse CT images were obtained before and after injection of contrast agent. Power Doppler US was performed in longitudinal, transverse, and coronal planes. Each kidney was divided into three zones for correlation of findings. RESULTS: Histopathologic examination revealed pyelonephritis in 102 zones in 38 kidneys. Sensitivity and specificity for detecting pyelonephritis in the kidneys were 92.1% and 93.8% for SPECT, 89.5% and 87.5% for MR imaging 86.8% and 87.5% for CT, and 74.3% and 56.7% for US. Sensitivity and specificity for detecting pyelonephritis in the zones were 94.1% and 95.4% for SPECT, 91.2% and 92.6% for MR imaging, 88.2% and 95.5% for CT, and 56.6% and 81.4% for US. The pairwise comparison of these modalities showed no statistically significant difference among them except for US. CONCLUSION: Tc-99m-DMSA SPECT, spiral CT, and MR imaging appear to be equally sensitive and reliable for the detection of acute pyelonephritis; power Doppler US is significantly less accurate.
引用
收藏
页码:101 / 108
页数:8
相关论文
共 27 条
  • [21] A Noninvasive [99mTc]DTPA SPECT/CT Imaging Methodology as a Measure of Lung Permeability in a Guinea Pig Model of COPD
    Yanjun Wu
    Charles J. Kotzer
    Sokratis Makrogiannis
    Gregory A. Logan
    Hyking Haley
    Mary S. Barnette
    Susanta K. Sarkar
    Molecular Imaging and Biology, 2011, 13 : 923 - 929
  • [22] A Noninvasive [99mTc]DTPA SPECT/CT Imaging Methodology as a Measure of Lung Permeability in a Guinea Pig Model of COPD
    Wu, Yanjun
    Kotzer, Charles J.
    Makrogiannis, Sokratis
    Logan, Gregory A.
    Haley, Hyking
    Barnette, Mary S.
    Sarkar, Susanta K.
    MOLECULAR IMAGING AND BIOLOGY, 2011, 13 (05) : 923 - 929
  • [23] Assessment of myocardial perfusion by harmonic power Doppler imaging at rest and during adenosine stress comparison with 99mTc-Sestamibi SPECT imaging
    Heinle, SK
    Noblin, J
    Goree-Best, P
    Mello, A
    Ravad, G
    Mull, S
    Mammen, P
    Grayburn, PA
    CIRCULATION, 2000, 102 (01) : 55 - 60
  • [24] Assessment of myocardial perfusion by harmonic power Doppler imaging at rest and during adenosine stress:: Comparison with 99mTc-Sestamibi-SPECT and coronary angiography
    Kuntz, S
    Tiemann, K
    Bangard, M
    Heinemann, A
    Pohl, C
    Ehlgen, A
    Biersack, HJ
    Krause, T
    Becher, H
    Lüderitz, B
    CIRCULATION, 2000, 102 (18) : 540 - 540
  • [25] Quantitative Analysis of Dynamic 99mTc-RP805 Lung SPECT/CT Images and Matrix Metalloproteinase Activity in Pig Model of Acute Respiratory Distress Syndrome
    Jang, Sun-Joo
    Thorn, Stephanie
    Zohora, Fatema Tuj
    Vermillion, Billy
    Alashi, Alaa
    Melvinsdottir, Inga
    Lee, Shin Rong
    Ahn, Shawn
    Burns, Rachel
    Dela Cruz, Charles
    Zeiss, Caroline
    Spinale, Francis
    Heerdt, Paul M.
    Sinusas, Albert
    JOURNAL OF NUCLEAR MEDICINE, 2024, 65
  • [26] Comparison of contrast-enhanced CT angiography and perfusion-angiography MR in the diagnosis of subsegmental sized pulmonary embolism: An experimental study in pig model
    Seo, JB
    Im, J
    Goo, J
    Chung, MJ
    Moon, WK
    Kim, I
    RADIOLOGY, 2001, 221 : 255 - 256
  • [27] Assessment of the ability of myocardial contrast echocardiography with harmonic power Doppler imaging to identity perfusion abnormalities in patients with Kawasaki disease at rest and during dipyridamole stress: Comparison with 99mTc-tetrofosmin single-photon emission computed tomography SPECT imaging
    Ishii, M
    Himeno, W
    Muta, H
    Sugahara, Y
    Kato, H
    CIRCULATION, 2001, 104 (17) : 515 - 515