Technetium-99m-DMSA renal cortical scintigraphy to detect experimental acute pyelonephritis in piglets: Comparison of planar (pinhole) and SPECT imaging

被引:0
|
作者
Majd, M
Rushton, HG
Chandra, R
Andrich, MP
Tardif, CP
Rashti, F
机构
[1] CHILDRENS NATL MED CTR,DEPT RADIOL NUCL MED,WASHINGTON,DC 20010
[2] CHILDRENS NATL MED CTR,DEPT UROL,WASHINGTON,DC 20010
[3] CHILDRENS NATL MED CTR,DEPT PATHOL,WASHINGTON,DC 20010
[4] GEORGE WASHINGTON UNIV,WASHINGTON,DC
关键词
pyelonephritis; technetium-99m-DMSA; SPECT; pinhole magnification;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this study was to directly compare the sensitivity and specificity of SPECT and pinhole imaging for the detection of acute pyelonephritis using histology as the standard of reference. Methods: Bilateral vesicoureteral reflux of infected urine was induced in 16 piglets (32 kidneys) by unroofing the intravesical ureter and subsequently instilling a broth culture of E. coli into the bladder, DMSA scans were obtained by both pinhole and SPECT techniques at 24 hr (4 piglets), 48 hr (5 piglets), 72 hr (4 piglets) and 10 days (3 piglets) after instillation of bacteria into the bladder. Kidneys were harvested immediately after scintigraphy for histopathologic examination. Results of the SPECT images, pinhole images and histologic findings were interpreted independently in a blinded fashion. The images of each kidney were classified as positive or negative for pyelonephritis regardless of the severity and number of lesions. To evaluate accuracy of SPECT and pinhole imaging for the detection of individual lesions, each kidney was arbitrarily divided into three zones (upper, middle and lower). Image findings were then compared with the pathology results for the presence or absence of pyelonephritis in each zone. Results: Histopathology revealed pyelonephritis in 24 of 32 kidneys (58 of 96 zones). The sensitivity of the DMSA scan for detection of affected kidneys was 92% for SPECT and 83% for pinhole; overall accuracy was 88% for both. The sensitivity of SPECT for the detection of affected renal zones was slightly better than pinhole imaging (91% compared with 86%), but its specificity was lower (82% compared with 95%) resulting in a similar accuracy. Excluding four piglets where scans were obtained within 24 hr after instillation of bacteria into the bladder, the sensitivity of SPECT and pinhole for the detection of affected kidneys were 95% and 90%, respectively. Their overall accuracy were 96% and 92%. In this subgroup, the sensitivity, specificity and accuracy of SPECT for the detection of involved zones were 96%, 95% and 96%, respectively. The corresponding values for pinhole imaging were 90%, 95% and 92%, respectively. Conclusion: Although the sensitivity of SPECT for the detection of acute pyelonephritis is slightly better than pinhole DMSA scan, the overall accuracy of these two imaging techniques is essentially the same.
引用
收藏
页码:1731 / 1734
页数:4
相关论文
共 50 条
  • [41] Comparison of 99mTc-DMSA Dual-Head SPECT Versus High-Resolution Parallel-Hole Planar Imaging for the Detection of Renal Cortical Defects
    Brenner, Michele
    Bonta, Dacian
    Eslamy, Hedieh
    Ziessman, Harvey A.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 193 (02) : 333 - 337
  • [42] 99mTc-DMSA planar imaging versus dual-detector SPECT for the detection of renal cortical scars in patients with CKD-3
    Tripathi, Madhavi
    Agarwal, Krishan Kant
    Mukherjee, Anirban
    Thukral, Parul
    Damle, Nishikant A.
    Shamim, Shamim A.
    Mahajan, Sandeep
    Bagchi, Soumita
    Bal, Chandrasekhar
    NUCLEAR MEDICINE COMMUNICATIONS, 2016, 37 (09) : 911 - 916
  • [43] Evaluation of Renal Split Function in Pediatric Patients with 99m-DMSA Scintigraphy, Comparison between Geometric Mean and Voxelbased Analysis on SPECT/ldCT
    Reichkendler, M. H.
    Borgwardt, L.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2017, 44 : S835 - S836
  • [44] A prospective comparison of posterior 180° and 360° 99mTc dimercaptosuccinic acid renal SPECT for the detection of renal cortical defects in acute pyelonephritis.
    Peng, NJ
    Chiou, YH
    Jao, GH
    Tsay, DC
    Liu, RS
    JOURNAL OF NUCLEAR MEDICINE, 2000, 41 (05) : 312P - 312P
  • [45] TECHNETIUM-99M PYROPHOSPHATE IMAGING IN ACUTE MYOCARDIAL-INFARCTION - COMPARISON OF PLANAR IMAGES WITH SUPERIMPOSITION TOMOGRAPHY
    CORBETT, J
    LEWIS, M
    WILLERSON, J
    HUXLEY, R
    SIMON, T
    NICOD, P
    HENDERSON, G
    RUDE, RE
    LEWIS, SE
    CIRCULATION, 1982, 66 (04) : 273 - 273
  • [46] Comparison of early SPECT/CT and dual-phase planar imaging with early SPECT/CT Tc-99m Sestamibi Parathyroid Scintigraphy. Can we avoid planar imaging?
    Gomez Hidalgo, J.
    Sainz-Esteban, A.
    Cobo Rodriguez, A.
    Gonzalez Selma, M.
    Ruiz Gomez, M.
    Gamazo Laherran, C.
    Alonso Rodriguez, M.
    Ruano Perez, R.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2017, 44 : S825 - S825
  • [47] Using technetium-99m dimercaptosuccinic acid renal cortex scintigraphy to differentiate acute pyelonephritis from other causes of fever in patients with spinal cord injury
    Kao, CH
    Hsieh, JP
    Tsai, SC
    Ho, YJ
    Changlai, SP
    Sun, SS
    Lee, JK
    UROLOGY, 2000, 55 (05) : 658 - 662
  • [48] Incremental value of Technetium-99m-labeled red blood cell planar scintigraphy(Tc99m RBC) versus Hybrid SPECT/CT in the outcomes of acute gastrointestinal bleeding(GIB).
    Gurajala, Ram
    Safar, Bandar
    Nasr, Elie
    Karuppasamy, Karunakaravel
    Shrikanthan, Sankaran
    JOURNAL OF NUCLEAR MEDICINE, 2015, 56 (03)
  • [49] INTRACORONARY THALLIUM-201-TECHNETIUM-99M SCINTIGRAPHY AFTER THROMBOLYSIS IN ACUTE MYOCARDIAL-INFARCTION - COMPARISON BETWEEN PLANAR SCINTIGRAPHY AND EMISSION COMPUTER-TOMOGRAPHY
    SCHOFER, J
    MATHEY, DG
    CLAUSEN, A
    MONTZ, R
    ZEITSCHRIFT FUR KARDIOLOGIE, 1985, 74 : 77 - 77
  • [50] Comparison of single-phase early SPECT/CT, dual-phase planar imaging with early SPECT and dual-phase planar imaging with early SPECT/CT Tc-99m Sestamibi Parathyroid Scintigraphy
    Gomez Hidalgo, Javier
    Cobo Rodriguez, Amparo
    Sainz-Esteban, A.
    Gamazo Laherran, Claudia
    Villanueva Curto, Juan Gabriel
    Ruiz Gomez, Maria Angeles
    Gonzalez Selma, Maria Luisa
    Alonso Rodriguez, Mercedes
    Olmos Garcia, Roberto
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2016, 43 : S575 - S575