A biomechanical study comparing minimally invasive anterior pelvic ring fixation techniques to external fixation

被引:14
|
作者
MacCormicka, Lauren M. [1 ]
Chen, Frank [2 ]
Gilbertson, Jeff [3 ]
Khana, Sikandar [1 ]
Schroder, Lisa K. [3 ]
Bechtolda, Joan E. [1 ,2 ]
Cole, Peter A. [1 ,3 ]
机构
[1] Univ Minnesota, Dept Orthopaed Surg, 2512 S 7th St,R200, Minneapolis, MN 55454 USA
[2] Excelen Ctr Bone & Joint Res & Educ, 700 10th Ave South, Minneapolis, MN 55415 USA
[3] Reg Hosp, Dept Orthopaed Surg, 640 Jackson St MS 11503L, St Paul, MN 55101 USA
来源
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED | 2019年 / 50卷 / 02期
关键词
Anterior pelvic ring fixation; Subcutaneous; Minimally invasive; INFIX; Pelvic Bridge; SUBCUTANEOUS INTERNAL FIXATOR; COMPLICATIONS; INJURIES; REDUCTION; FRACTURES; LOADS;
D O I
10.1016/j.injury.2018.07.011
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Introduction: INFIX and Pelvic Bridge are two new minimally invasive surgical techniques for unstable pelvic ring injuries, and they have demonstrated early clinical success in small, single-center case-series. The primary objective of this study is to gather evidence speaking to the biomechanical stability of internal bridging methods relative to external fixation, with the expectation of biomechanical equivalence. Methods: Ten human cadaveric pelvic specimens were dissected free of all skin, fat, organs, and musculature and were prepared with a partially unstable pelvic ring injury (OTA/AO 61-B). The specimens were randomized to two groups and were repaired and tested with anterior pelvic external fixation (APEF) and INFIX sequentially, or APEF and Pelvic Bridge sequentially. Testing was performed with each specimen mounted onto a servo-hydraulic testing frame with axial compression applied to the superior base of the sacrum under five axial loading/unloading sinusoidal cycles between 10 N and 1000 N at 0.1 Hz. Relative translational motion and rotation across the osteotomy site was reported as our primary outcome measures. Outcome measures were further analyzed using a Wilcoxon signed-rank test to determine differences between non-parametric data sets with significance defined as a p value < 0.05. Results: We found no statistical difference in translation (p = 0.237, 0.228) or rotation (p = 0.278, 0.873) at the fracture site when comparing both new constructs to external fixation. Under the imposed loading protocol, no episodes of implant failure or failure at the bone-implant interface occurred. Discussion: Our study provides the biomechanical foundation necessary to support future clinical trial implementation for pelvic fracture patients. While biomechanical stability of these newer, subcutaneous techniques is equivalent to APEF, the surgeon must take into account their technical abilities and knowledge of pelvic anatomy, patient-specific factors including body habitus, and the potential complications associated with each implant and the ability to avoid them. (C) 2018 Elsevier Ltd. All rights reserved.
引用
收藏
页码:251 / 255
页数:5
相关论文
共 50 条
  • [41] Starr frame-assisted minimally invasive internal fixation for pelvic fractures: Simultaneous anterior and posterior ring stability
    Xu, Lei
    Xie, Kai
    Zhu, Wanbo
    Yang, Jiazhao
    Xu, Wei
    Fang, Shiyuan
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2023, 54 : S15 - S20
  • [42] Minimally Invasive Percutaneous TightRope® System Fixation for an Unstable Posterior Pelvic Ring: Clinical Follow-up and Biomechanical Studies
    Gu, Feng
    Zhang, Jiting
    Sui, Zhenjiang
    Zhang, Ke
    Xie, Xiaoping
    Yu, Tiecheng
    ORTHOPAEDIC SURGERY, 2022, 14 (06) : 1078 - 1092
  • [43] Minimally Invasive Surgery for Unstable Pelvic Ring Fractures: Transiliac Rod and Screw Fixation
    Toda, Kazukiyo
    Yagata, Yukihisa
    Kikuchi, Takeshi
    Takigawa, Tomoyuki
    Ito, Yasuo
    ACTA MEDICA OKAYAMA, 2020, 74 (01) : 27 - 32
  • [44] External Ring Fixation Versus Screw Fixation for Ankle Arthrodesis: A Biomechanical Comparison
    Ogut, Tahir
    Glisson, Richard R.
    Chuckpaiwong, Bavornrit
    Le, Ian L. D.
    Easley, Mark E.
    FOOT & ANKLE INTERNATIONAL, 2009, 30 (04) : 353 - 360
  • [45] Minimally Invasive Fluoro-Navigation Screw Fixation for the Treatment of Pelvic Ring Injuries
    Gao, Hong
    Luo, Cong-Feng
    Hu, Cheng-Fang
    Zhang, Chang-Qing
    Zeng, Bing-Fang
    SURGICAL INNOVATION, 2011, 18 (03) : 279 - 284
  • [46] Minimally invasive screw fixation is as stable as anterior plating in acetabular T-Type fractures - a biomechanical study
    Becker, Christopher A.
    Kammerlander, Christian
    Kussmaul, Adrian Cavalcanti
    Dotzauer, Fabian
    Woiczinski, Matthias
    Rubenbauer, Bianka
    Sommer, Fabian
    Linhart, Christoph
    Weidert, Simon
    Zeckey, Christian
    Greiner, Axel
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2018, 104 (07) : 1055 - 1061
  • [47] Does minimally invasive external fixation of proximal humerus fractures provide adequate stability? A biomechanical in vitro study
    Greinwald, Markus
    Matschl, Franz
    Regenbogen, Stephan
    Paetzold, Robert
    Blonna, Davide
    Augat, Peter
    BMC MUSCULOSKELETAL DISORDERS, 2024, 25 (01)
  • [48] BIOMECHANICAL STUDIES OF AN ANTERIOR PELVIC EXTERNAL FIXATION FRAME INTENDED FOR CONTROL OF VERTICAL SHEAR FRACTURES
    DAHNERS, LE
    JACOBS, RR
    MCKENZIE, EB
    GILBERT, JA
    SOUTHERN MEDICAL JOURNAL, 1986, 79 (07) : 815 - 817
  • [49] Biomechanical study on surgical fixation methods for minimally invasive treatment of hallux valgus
    Mao, Rui
    Guo, Junchao
    Luo, Chenyu
    Fan, Yubo
    Wen, Jianmin
    Wang, Lizhen
    MEDICAL ENGINEERING & PHYSICS, 2017, 46 : 21 - 26
  • [50] Modified pedicle screw-rod fixation as a minimally invasive treatment for anterior pelvic ring injuries: an initial case series
    Wu, Xiaotian
    Liu, Zuoqing
    Fu, Wenqin
    Zhao, Shan
    Feng, Juntao
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2017, 12