A biomechanical study comparing minimally invasive anterior pelvic ring fixation techniques to external fixation

被引:14
|
作者
MacCormicka, Lauren M. [1 ]
Chen, Frank [2 ]
Gilbertson, Jeff [3 ]
Khana, Sikandar [1 ]
Schroder, Lisa K. [3 ]
Bechtolda, Joan E. [1 ,2 ]
Cole, Peter A. [1 ,3 ]
机构
[1] Univ Minnesota, Dept Orthopaed Surg, 2512 S 7th St,R200, Minneapolis, MN 55454 USA
[2] Excelen Ctr Bone & Joint Res & Educ, 700 10th Ave South, Minneapolis, MN 55415 USA
[3] Reg Hosp, Dept Orthopaed Surg, 640 Jackson St MS 11503L, St Paul, MN 55101 USA
来源
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED | 2019年 / 50卷 / 02期
关键词
Anterior pelvic ring fixation; Subcutaneous; Minimally invasive; INFIX; Pelvic Bridge; SUBCUTANEOUS INTERNAL FIXATOR; COMPLICATIONS; INJURIES; REDUCTION; FRACTURES; LOADS;
D O I
10.1016/j.injury.2018.07.011
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Introduction: INFIX and Pelvic Bridge are two new minimally invasive surgical techniques for unstable pelvic ring injuries, and they have demonstrated early clinical success in small, single-center case-series. The primary objective of this study is to gather evidence speaking to the biomechanical stability of internal bridging methods relative to external fixation, with the expectation of biomechanical equivalence. Methods: Ten human cadaveric pelvic specimens were dissected free of all skin, fat, organs, and musculature and were prepared with a partially unstable pelvic ring injury (OTA/AO 61-B). The specimens were randomized to two groups and were repaired and tested with anterior pelvic external fixation (APEF) and INFIX sequentially, or APEF and Pelvic Bridge sequentially. Testing was performed with each specimen mounted onto a servo-hydraulic testing frame with axial compression applied to the superior base of the sacrum under five axial loading/unloading sinusoidal cycles between 10 N and 1000 N at 0.1 Hz. Relative translational motion and rotation across the osteotomy site was reported as our primary outcome measures. Outcome measures were further analyzed using a Wilcoxon signed-rank test to determine differences between non-parametric data sets with significance defined as a p value < 0.05. Results: We found no statistical difference in translation (p = 0.237, 0.228) or rotation (p = 0.278, 0.873) at the fracture site when comparing both new constructs to external fixation. Under the imposed loading protocol, no episodes of implant failure or failure at the bone-implant interface occurred. Discussion: Our study provides the biomechanical foundation necessary to support future clinical trial implementation for pelvic fracture patients. While biomechanical stability of these newer, subcutaneous techniques is equivalent to APEF, the surgeon must take into account their technical abilities and knowledge of pelvic anatomy, patient-specific factors including body habitus, and the potential complications associated with each implant and the ability to avoid them. (C) 2018 Elsevier Ltd. All rights reserved.
引用
收藏
页码:251 / 255
页数:5
相关论文
共 50 条
  • [21] Simple anterior pelvic external fixation
    Tucker, MC
    Nork, SE
    Simonian, PT
    Routt, MLC
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2000, 49 (06): : 989 - 994
  • [22] Fixation of Anterior Pelvic Ring Injuries
    Wojahn, Robert D.
    Gardner, Michael J.
    JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2019, 27 (18) : 667 - 676
  • [23] Fixation of Anterior Pelvic Ring Injuries
    Vaidya, Rahul
    JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2020, 28 (13) : E550 - E551
  • [24] External fixation for pelvic ring disruptions
    Yang, AP
    Iannacone, WM
    ORTHOPEDIC CLINICS OF NORTH AMERICA, 1997, 28 (03) : 331 - &
  • [25] Simultaneous anterior and posterior compression of the pelvic ring with external fixation using a pre-tensed curved bar: A biomechanical study
    Queipo-de-Llano, Alfonso
    Perez-Blanca, Ana
    Ezquerro, Francisco
    Luna-Gonzalez, Felipe
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2013, 44 (12): : 1787 - 1792
  • [26] Biomechanical comparison of posterior pelvic ring fixation
    Yinger, K
    Scalise, J
    Olson, SA
    Bay, BK
    Finkemeier, CG
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2003, 17 (07) : 481 - 487
  • [27] Biomechanical comparison of five different external fixation configurations for pelvic ring instability
    Osterhoff, Georg
    Tiziani, Simon
    Ferguson, Stephen J.
    Spreiter, Gregor
    Wanner, Guido A.
    Simmen, Hans-Peter
    Werner, Clement M. L.
    SWISS MEDICAL WEEKLY, 2013, 143 : 22S - 22S
  • [28] Minimally invasive fusion and fixation techniques
    Powers, Ciaran J.
    Isaacs, Robert E.
    NEUROSURGERY CLINICS OF NORTH AMERICA, 2006, 17 (04) : 477 - +
  • [29] Modified minimally invasive percutaneous bridge fixation technique for the treatment of unstable anterior pelvic ring fractures in males
    Hu, Li-Feng
    Dong, Sheng-Li
    Yu, Kai
    Zhang, Dian-Ying
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2019, 12 (06): : 7651 - 7656
  • [30] Clinical research on minimally invasive internal fixation for the treatment of anterior ring injury in tile C pelvic fracture
    Sun, Xiaochen
    Yan, Huimin
    Wang, Jianmin
    Liu, Zhaojie
    Tian, Wei
    Jia, Jian
    MEDICINE, 2020, 99 (30) : E20652