A theoretical study of CsI:Tl columnar scintillator image quality parameters by analytical modeling

被引:12
|
作者
Kalyvas, N. [1 ]
Valais, I. [1 ]
Michail, C. [1 ]
Fountos, G. [1 ]
Kandarakis, I. [1 ]
Cavouras, D. [1 ]
机构
[1] Technol Educ Inst TEI Athens, Dept Biomed Engn, Athens 12210, Greece
关键词
CsI:Tl; Columnar phosphors; Modeling; MTF; DQE; FLAT-PANEL IMAGER; SPATIAL-RESOLUTION; RAY; EFFICIENCY; PERFORMANCE; DETECTOR; NOISE; PHOSPHORS; QUANTUM; OPTIMIZATION;
D O I
10.1016/j.nima.2015.01.027
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Medical X-ray digital imaging systems such as mammography, radiography and computed tomography (CT), are composed from efficient radiation detectors, which can transform the X-rays to electron signal. Scintillators are materials that emit light when excited by X-rays and incorporated in X-ray medical imaging detectors. Columnar scintillator, like CsI:Tl is very often used for X-ray detection due to its higher performance. The columnar form limits the lateral spread of the optical photons to the scintillator output, thus it demonstrates superior spatial resolution compared to granular scintillators. The aim of this work is to provide an analytical model for calculating the MTF, the DQE and the emission efficiency of a columnar scintillator. The model parameters were validated against published Monte Carlo data The model was able to predict the overall performance of CsliTl scintillators and suggested an optimum thickness of 300 pm for radiography applications. (C) 2015 Elsevier B.V. All rights reserved
引用
收藏
页码:18 / 24
页数:7
相关论文
共 50 条
  • [41] Accelerating image acquisition in 64-MDCT: the influence of scan parameters on image resolution and quality in a phantom study
    Klink, Thorsten
    Regier, Marc
    van Stevendaal, Udo
    Grass, Michael
    Adam, Gerhard
    Begemann, Philipp
    CLINICAL IMAGING, 2012, 36 (04) : 334 - 344
  • [42] Study on Effects of Scan Parameters on the Image Quality and Tip Wear in AFM Tapping Mode
    Xue, Bo
    Yan, Yongda
    Hu, Zhenjiang
    Zhao, Xuesen
    SCANNING, 2014, 36 (02) : 263 - 269
  • [43] Comparative study of DR image De-noising method based on quality parameters
    Chakraborty, Monisha
    Mondal, Manishankar
    FOUNDATIONS AND FRONTIERS IN COMPUTER, COMMUNICATION AND ELECTRICAL ENGINEERING, 2016, : 299 - 303
  • [44] Comparison of a-Se direct.-conversion and CsI(Tl) indirect-conversion flat-panel digital detectors: A clinical assessment of image quality for general radiography applications
    Barski, Lori L.
    Wang, Xiaohui
    Wandtke, John
    Waldman, David
    Davis, Delphine
    Foos, David H.
    Dupin, Michael
    Huang, Weidong
    Yorkston, John
    MEDICAL IMAGING 2006: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2006, 6142
  • [45] Towards better understanding the stiffness of nanocomposites via parametric study of an analytical model modeling parameters and experiments
    Demir, Eyup Can
    McDermott, Mark T.
    Kim, Chun ll
    Ayranci, Cagri
    JOURNAL OF COMPOSITE MATERIALS, 2023, 57 (06) : 1087 - 1104
  • [46] Modeling and Analytical Solution of Hybrid Thermopiezoelectric Micro Actuator and Performance Study Under Changing of Different Parameters
    Pourrostami, Hasan
    Kargarnovin, Mohamad H.
    Zohoor, Hassan
    MECHANICS OF ADVANCED MATERIALS AND STRUCTURES, 2015, 22 (10) : 785 - 793
  • [47] A Fuzzy Based Ranking of Dominance among Water Quality Parameters for Modeling: A Case Study
    Ravichandran, K. S.
    Rajaram, T.
    Das, Ashutosh
    INTERNATIONAL JOURNAL OF ECOLOGY & DEVELOPMENT, 2006, 4 (02) : 51 - 61
  • [48] Comparative study of NIR spectroscopy and traditional analytical methods in the determination of orange juice nutritional quality parameters
    Miro, Esteban
    Boido, Eduardo
    Farina, Laura
    Piston, Mariela
    Dellacassa, Eduardo
    JOURNAL OF FOOD COMPOSITION AND ANALYSIS, 2025, 140
  • [49] A STUDY OF THE RELATIONSHIP BETWEEN ROUTINE ULTRASOUND QUALITY ASSURANCE PARAMETERS AND SUBJECTIVE OPERATOR IMAGE ASSESSMENT
    METCALFE, SC
    EVANS, JA
    BRITISH JOURNAL OF RADIOLOGY, 1992, 65 (775): : 570 - 575
  • [50] Feasibility study of hybrid scanning technique parameters on dose reduction and CT-image quality
    Kim, Dohyeon
    Lee, Haenghwa
    Shin, Dong-Seok
    Lee, Youngjin
    RADIATION PHYSICS AND CHEMISTRY, 2025, 226