3D-TOF sensors in the automobile

被引:3
|
作者
Kahlmann, T [1 ]
Oggier, T [1 ]
Lustenberger, F [1 ]
Blanc, N [1 ]
Ingensand, H [1 ]
机构
[1] Swiss Fed Inst Technol, CH-8093 Zurich, Switzerland
来源
Photonics in the Automobile | 2005年 / 5663卷
关键词
range image; time-of-flight; range camera; calibration; 3D-positioning system;
D O I
10.1117/12.607261
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
In recent years, pervasive computing has become an important topic in automobile industry. Besides well-known driving assistant systems such as ABS, ASR and ESP several small tools that support driving activities were developed. The most important reason for integrating new technologies is to increase the safety of passengers as well as road users. The Centre Suisse d'Electronique et de Microtechnique SA (CSEM) Zurich presented the CMOS/CCD real-time range-imaging technology, a measurement principle with a wide field of applications in automobiles. The measuring system is based on the time-of-flight measurement principle using actively modulated radiation. Thereby, the radiation is emitted by the camera's illumination system, reflected by objects in the field of view and finally imaged on the CMOS/CCD sensor by the optics. From the acquired radiation, the phase delay and hence the target distance is derived within each individual pixel. From these distance measurements, three-dimensional coordinates can then be calculated. The imaging sensor acquires its environment data in a high-frequency mode and is therefore appropriate for real-time applications. The basis for decisions which contribute to the increased safety is thus available. In this contribution, first the operational principle of the sensor technology is outlined. Further, some implementations of the technology are presented. At the laboratories of the Institute of Geodesy and Photogrammetry (IGP) at ETH Zurich an implementation of the above mentioned measurement principle, the SwissRangerTM, was investigated in detail. Special attention was focused on the characteristics of this sensor and its calibration. Finally, sample applications within the automobile are introduced.
引用
收藏
页码:216 / 224
页数:9
相关论文
共 50 条
  • [1] A Method for evaluating 3D-TOF camera ranging performance
    Song Yuzhi
    Lu Chunqing
    Wu Fenzhi
    Cao Zhongxiang
    Liang Xiao
    SIXTH SYMPOSIUM ON NOVEL OPTOELECTRONIC DETECTION TECHNOLOGY AND APPLICATIONS, 2020, 11455
  • [2] Robot vision system based on a 3D-TOF camera
    Hussmann, Stephan
    Liepert, Thorsten
    2007 IEEE INSTRUMENTATION & MEASUREMENT TECHNOLOGY CONFERENCE, VOLS 1-5, 2007, : 1405 - 1409
  • [3] Role of 3D-TOF magnetic resonance angiography for intracranial meningioma
    Abe, T
    Matsumoto, K
    Hanakawa, K
    Homma, H
    Kawamura, N
    Ikeda, H
    Horichi, Y
    Hayashi, T
    JOURNAL OF CLINICAL NEUROSCIENCE, 1998, 5 (04) : 387 - 389
  • [4] High Quality Depth Map Upsampling for 3D-TOF Cameras
    Park, Jaesik
    Kim, Hyeongwoo
    Tai, Yu-Wing
    Brown, Michael S.
    Kweon, Inso
    2011 IEEE INTERNATIONAL CONFERENCE ON COMPUTER VISION (ICCV), 2011, : 1623 - 1630
  • [5] Integration of a 3D-TOF camera into an autonomous, mobile robot system
    Hussmann, Stephan
    Schauer, Daniel
    MacDonald, Bruce
    I2MTC: 2009 IEEE INSTRUMENTATION & MEASUREMENT TECHNOLOGY CONFERENCE, VOLS 1-3, 2009, : 528 - +
  • [6] 3.0T MR颅脑的3D-TOF MRA
    尉传社
    袁飞
    顾欣
    冯凯琳
    龙淼淼
    吴胜勇
    不详
    放射学实践 , 2005, (10) : 897 - 900
  • [7] Neurovascular stent artifacts in 3D-TOF and 3D-PCMRI: Influence of stent design on flow measurement
    Bouillot, Pierre
    Brina, Olivier
    Delattre, Benedicte M. A.
    Ouared, Rafik
    Pellaton, Alain
    Yilmaz, Hasan
    Machi, Paolo
    Lovblad, Karl-Olof
    Farhat, Mohamed
    Pereira, Vitor Mendes
    Vargas, Maria Isabel
    MAGNETIC RESONANCE IN MEDICINE, 2019, 81 (01) : 560 - 572
  • [8] High signal intensity in the dural sinuses on 3D-TOF MR angiography at 3.0 T
    Inano, Sachiko
    Itoh, Daisuke
    Takao, Hidemasa
    Hayashi, Naoto
    Mori, Harushi
    Kunimatsu, Akira
    Abe, Osamu
    Aoki, Shigeki
    Ohtomo, Kuni
    CLINICAL IMAGING, 2010, 34 (05) : 332 - 336
  • [9] 3D-TOF MRA技术诊断脑Willis环变异的价值
    王莉
    影像研究与医学应用, 2018, 2 (20) : 20 - 23
  • [10] Circle of Willis: Anatomic variations on 3D-TOF MRA from childhood to young adulthood
    Ansari, S
    Enochs, WS
    Friedman, DP
    RADIOLOGY, 2001, 221 : 347 - 347